Assessment of Thermal Aging Degree of 10kV Cross-Linked Polyethylene Cable Based on Depolarization Current

被引:13
|
作者
Zhang, Yi-Yi [1 ]
Jiang, Feng-Yu [1 ,2 ]
Yu, Xiao-Yong [3 ]
Zhou, Ke [3 ]
Zhang, Wei [3 ]
Fu, Qiang [4 ]
Hao, Jian [5 ]
机构
[1] Guangxi Univ, Guangxi Key Lab Power Syst Optimizat & Energy Tec, Nanning 530004, Peoples R China
[2] Zhengzhou Univ, Coll Elect Engn, Zhengzhou 450000, Peoples R China
[3] Guangxi Elect Power Res Inst, Nanning 530000, Peoples R China
[4] China Southern Power Grid Co Ltd, Elect Power Res Inst, Guangzhou 510080, Peoples R China
[5] Chongqing Univ, State Key Lab Power Transmiss & Distribut Equipme, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
XLPE cable; polarization/depolarization current (PDC); thermal aging; insulation diagnosis; aging factor; elongation at break; INSULATION; DOMAIN; TIME;
D O I
10.1109/ACCESS.2021.3066654
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
During the long-term operation of high-voltage cross-linked polyethylene (XLPE) cables, the cable will gradually deteriorate under the effect of various aging factors. Thermal aging is one of the key factors directly related to the long-term operation reliability of the XLPE cables. In this paper, the thermal aging samples are prepared for PDC measurement. Based on the polymer trap theory and the extended Debye model, the shape of PDC curve, depolarization charge, parameters of the extended Debye model, aging factor (A), elongation at break retention rate (EB%) and their relationships under different thermal aging degrees are analyzed. The results show that the depolarization current curve and the depolarization charge can preliminarily judge the aging condition of the XLPE, but it is not accurate enough. R-3 and tau(3) of the branch, with the largest time constant must be the most sensitive to cable aging. With the increase of aging degree, the A shows an upward trend, and has a nonlinear relationship with EB%. Under the aging temperature of 140 degrees C, after 15-25 days of aging, the A suggests the samples are in the moderate to severe aging stage, and the PDC test should be performed on carried out for the cables with that have been used for 21 years of operation to evaluate the insulation aging condition. The study reveals that the PDC-based parameters can be serviced as an effective tool for the aging condition prediction of XLPE cable insulation.
引用
收藏
页码:111020 / 111029
页数:10
相关论文
共 50 条
  • [31] Thermal aging of electrical cable insulation made of cross-linked low density polyethylene for under-hood application in automotive industry
    Salivon, Tetiana
    Comte, Raphael
    Colin, Xavier
    JOURNAL OF VINYL & ADDITIVE TECHNOLOGY, 2022, 28 (02): : 418 - 429
  • [32] Electro-thermal breakdown measurement of 500 kV cross-linked polyethylene submarine cable insulation material and its lifetime model analysis
    Hao, Jian
    Liu, Zhiqian
    Liao, Ruijin
    Li, Jian
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2020, 14 (10) : 862 - 869
  • [33] Analysis of yellowing phenomenon caused by electrical and thermal degradation in the interface of cross-linked polyethylene cable joints
    Yoon, Sungho
    Son, Hyeongwook
    Ko, Hyeongsang
    Kim, Jeongtae
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2022, 16 (09) : 503 - 511
  • [34] Mechanistic insights into the thermal-mechanical aging of the interface of cross-linked polyethylene/silicone rubber
    Zhang, Tianfeng
    Zhang, Yunxiao
    Zheng, Xin
    Lin, Wenxin
    Zhang, Zenghui
    Chi, Zhengnan
    Zhang, Jiarui
    Teng, Chenyuan
    JOURNAL OF APPLIED POLYMER SCIENCE, 2024, 141 (12)
  • [35] Changes in Chemical Structure and Mechanical Properties Induced in Cross-linked Polyethylene by Thermal and Radiation Aging
    Miyazaki, Yu
    Hirai, Naoshi
    Ohki, Yoshimichi
    PROCEEDINGS OF THE 2020 3RD IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD 2020), 2020, : 45 - 48
  • [36] Electric intensity distribution of cross-linked polyethylene based high-voltage cable termination
    Luo, Yong
    Chen, Dingke
    Chen, Chun
    International Journal of Mechatronics and Applied Mechanics, 2019, 2019 (05): : 45 - 50
  • [37] Performance of Cross-Linked Polyethylene Insulated Cable Based on Detection of High Voltage Electric Field
    Luo, Yong
    Luo, Jiawei
    Li, Bin
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2019, 20 (01) : 40 - 45
  • [38] Performance of Cross-linked Polyethylene Insulated Cable based on Detection of High Voltage Electric Field
    Luo, Y.
    Luo, J.
    Li, B.
    INTERNATIONAL JOURNAL OF MULTIPHYSICS, 2019, 13 (02) : 147 - 156
  • [39] Performance of Cross-Linked Polyethylene Insulated Cable Based on Detection of High Voltage Electric Field
    Yong Luo
    Jiawei Luo
    Bin Li
    Transactions on Electrical and Electronic Materials, 2019, 20 : 40 - 45
  • [40] Aging Mechanisms and Nondestructive Aging Indicator of Filled Cross-Linked Polyethylene (XLPE) Exposed to Simultaneous Thermal and Gamma Radiation
    Liu, Shuaishuai
    Fifield, Leonard S.
    Bowler, Nicola
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL DEGRADATION OF MATERIALS IN NUCLEAR POWER SYSTEMS - WATER REACTORS, VOL 2, 2018, : 65 - 75