Implementation of Energy Performance Assessment System for Existing Building

被引:0
|
作者
Jeong, Youn-Kwae [1 ]
Kim, Taehyung [1 ]
Nam, Hong-Soon [1 ]
Lee, Il-Woo [1 ]
机构
[1] ETRI, Daejeon, South Korea
关键词
Existing building; building energy performance; assessment; building energy model; Bayesian calibration; ECM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we describe the implementation of building energy performance assessment system to evaluate the energy performance of existing building for energy efficiency improvement by building remodeling. In consideration of the performance effect of building structure and operation, we created a stochastic building energy model based on ISO13790 and EN15232 building energy model. In order to make the model accurately, we adopted energy consumption data and Bayesian calibration method to predict the current value of uncertainty parameters according to aging related to various building components. Also, it can provide Energy Conservation Measures (ECM) for remodeling of existing building.
引用
收藏
页码:393 / 395
页数:3
相关论文
共 50 条
  • [21] Implementation of battery inspection system for building energy management system
    Kim, Seong-Kweon, 1600, Inderscience Enterprises Ltd., 29, route de Pre-Bois, Case Postale 856, CH-1215 Geneva 15, CH-1215, Switzerland (09):
  • [22] A study on building performance analysis for energy retrofit of existing industrial facilities
    Gourlis, Georgios
    Kovacic, Iva
    APPLIED ENERGY, 2016, 184 : 1389 - 1399
  • [23] Review of the Building Information Modelling (BIM) Implementation in the Context of Building Energy Assessment
    Durdyev, Serdar
    Dehdasht, Gholamreza
    Mohandes, Saeed Reza
    Edwards, David J.
    ENERGIES, 2021, 14 (24)
  • [24] Performance Assessment of Building by Virtual Energy Audit
    Joshi, Atharav
    Mundada, Akash
    Suryavanshi, Yash
    Kurulekar, Maya
    Ranade, Mrunmai
    Jadhav, Nilesh
    Jabade, Siddarth
    Patil, Kailash
    Despande, Yogesh
    PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE AND UTILITY EXHIBITION ON GREEN ENERGY FOR SUSTAINABLE DEVELOPMENT (ICUE 2018), 2018,
  • [25] A Demand Response Implementation with Building Energy Management System
    Charoen, Prasertsak
    Kitbutrawat, Nathavuth
    Kudtongngam, Jasada
    ENERGIES, 2022, 15 (03)
  • [26] Building energy performance simulation: a case study of modelling an existing residential building in Saudi Arabia
    Alyami, Mana
    Omer, Siddig
    ENVIRONMENTAL RESEARCH: INFRASTRUCTURE AND SUSTAINABILITY, 2021, 1 (03):
  • [27] Multi-criteria assessment of building performance, theory and implementation
    Soebarto, VI
    Williamson, TJ
    BUILDING AND ENVIRONMENT, 2001, 36 (06) : 681 - 690
  • [28] Seismic Assessment of Existing Masonry Building
    Osmanovic, Nadzija
    Medic, Senad
    Hrasnica, Mustafa
    ADVANCED TECHNOLOGIES, SYSTEMS, AND APPLICATIONS III, VOL 2, 2019, 60 : 52 - 61
  • [29] How to approach the assessment of an existing building
    Lawrence A.
    Hill R.
    Fernandez S.
    Structural Engineer, 2023, 101 (10): : 10 - 13
  • [30] Building Integrated Shading and Building Applied Photovoltaic System Assessment in the Energy Performance and Thermal Comfort of Office Buildings
    Martinopoulos, Georgios
    Serasidou, Anna
    Antoniadou, Panagiota
    Papadopoulos, Agis M.
    SUSTAINABILITY, 2018, 10 (12)