Numerical study on natural convection heat transfer of annular finned tube heat exchanger in chimney with experimental data

被引:20
|
作者
Chen, Han-Taw [1 ]
Chou, Hsin-Yu [1 ]
Tseng, Hung-Chia [1 ]
Chang, Jiang-Ren [2 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 701, Taiwan
[2] Natl Taiwan Ocean Univ, Dept Syst Engn & Naval Architecture, Keelung 202, Taiwan
关键词
CFD and inverse method; Natural convection; Annular finned tube; Chimney; HORIZONTAL CYLINDER; TRANSFER COEFFICIENT; PERFORMANCE; DIAMETERS; FINS;
D O I
10.1016/j.ijheatmasstransfer.2018.08.055
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents a hybrid method of inverse method and three-dimensional computational fluid dynamics (CFD) commercial software along with experimental data and various flow models to investigate the natural convection heat transfer and fluid flow characteristics of vertical annular finned tube heat exchangers in a small chimney for various fin diameters. First, the inverse method of the finite difference method along with experimental temperature data is used to estimate the heat transfer coefficient on the fins. Afterwards, the CFD along with various flow models and the inverse results of the heat transfer coefficient is used to determine the air temperature and velocity profiles, the fin surface temperature and the heat transfer coefficient on the fins. More accurate results are obtained when the resulting heat transfer coefficient and fin temperature are as close as possible to the inverse results and the experimental temperature measurements, respectively. The results show that the zero-equation turbulence model is more suitable for this problem than other flow models, especially for larger fin spacing. The more grid points are not necessarily able to obtain more accurate results. The choice of the appropriate flow model and the number of grid points may depend on experimental temperature data and reliable heat transfer coefficient. Finally, it is found that the heat transfer coefficient increases with decreasing fin diameter and increasing fin spacing. Fin efficiency decreases with increasing fin diameter and fin spacing. The optimum fin spacing can vary with the D/d(0) value. Also, the proposed correlation between the Nusselt number and the Rayleigh number matches the inverse and numerical results obtained. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:483 / 496
页数:14
相关论文
共 50 条
  • [31] Effect of material and geometric parameters on natural convection heat transfer over an eccentric annular-finned tube
    Fourar, Issam
    Benmachiche, Abdelmoumene Hakim
    Abboudi, Said
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, 42 (08) : 929 - 939
  • [32] Mixed convection heat transfer: an experimental study on Cu/heat transfer oil nanofluids inside annular tube
    Arani, Ali Akbar Abbasian
    Aberoumand, Hossein
    Jafarimoghaddam, Amin
    Aberoumand, Sadegh
    HEAT AND MASS TRANSFER, 2017, 53 (09) : 2875 - 2884
  • [33] Mixed convection heat transfer: an experimental study on Cu/heat transfer oil nanofluids inside annular tube
    Ali Akbar Abbasian Arani
    Hossein Aberoumand
    Amin Jafarimoghaddam
    Sadegh Aberoumand
    Heat and Mass Transfer, 2017, 53 : 2875 - 2884
  • [34] Experimental and numerical study on the optimal fin numbering in an external extended finned tube heat exchanger
    Sajedi, R.
    Taghilou, M.
    Jafari, M.
    APPLIED THERMAL ENGINEERING, 2015, 83 : 139 - 146
  • [35] Experimental comparison of finned tube heat exchangers for heat rejection under natural convection conditions
    Matuszczak, Miko laj
    Nycz, Karol
    Mazurek, Wojciech
    Krowicki, Pawe
    Pietrowicz, Slawomir
    Pandelidis, Demis
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 154
  • [36] Numerical investigation on heat and mass transfer of slit finned tube heat exchanger with humid flue gas
    Wang, Limin
    Shao, Yaru
    Tang, Chunli
    He, Yang
    Jin, Wanlong
    Che, Defu
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2022, 17 (02)
  • [37] Natural convection heat transfer performance and optimization of longitudinal finned tube in vertical
    School of Energy and Power Engineering, Shandong University, Jinan 250061, China
    Kung Cheng Je Wu Li Hsueh Pao, 2008, 9 (1537-1540):
  • [38] Numerical and analytical investigations of heat transfer for a finned tube heat exchanger with ice slurry as cooling medium
    Long, Youwei
    Wang, Shugang
    Wang, Jihong
    Zhang, Tengfei
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (03) : 478 - 489
  • [39] Using the Inverse Method to Investigate Flow Models for Mixed Convection of Annular Finned Tube Heat Exchanger
    Chen, Han-Taw
    You, Cheng-Hui
    Hsu, Wei-Lun
    Chang, Jiang-Ren
    JOURNAL OF MARINE SCIENCE AND TECHNOLOGY-TAIWAN, 2021, 29 (05): : 652 - 665
  • [40] A Numerical Investigation on Natural Convection Heat Transfer in Annular-Finned Concentric Horizontal Annulus Using Nanofluids: A Parametric Study
    Ashouri, Mahyar
    Zarei, Mohammad Mehdi
    Hakkaki-Fard, Ali
    HEAT TRANSFER ENGINEERING, 2021, 42 (22) : 1926 - 1948