Numerical study on natural convection heat transfer of annular finned tube heat exchanger in chimney with experimental data

被引:20
|
作者
Chen, Han-Taw [1 ]
Chou, Hsin-Yu [1 ]
Tseng, Hung-Chia [1 ]
Chang, Jiang-Ren [2 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 701, Taiwan
[2] Natl Taiwan Ocean Univ, Dept Syst Engn & Naval Architecture, Keelung 202, Taiwan
关键词
CFD and inverse method; Natural convection; Annular finned tube; Chimney; HORIZONTAL CYLINDER; TRANSFER COEFFICIENT; PERFORMANCE; DIAMETERS; FINS;
D O I
10.1016/j.ijheatmasstransfer.2018.08.055
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents a hybrid method of inverse method and three-dimensional computational fluid dynamics (CFD) commercial software along with experimental data and various flow models to investigate the natural convection heat transfer and fluid flow characteristics of vertical annular finned tube heat exchangers in a small chimney for various fin diameters. First, the inverse method of the finite difference method along with experimental temperature data is used to estimate the heat transfer coefficient on the fins. Afterwards, the CFD along with various flow models and the inverse results of the heat transfer coefficient is used to determine the air temperature and velocity profiles, the fin surface temperature and the heat transfer coefficient on the fins. More accurate results are obtained when the resulting heat transfer coefficient and fin temperature are as close as possible to the inverse results and the experimental temperature measurements, respectively. The results show that the zero-equation turbulence model is more suitable for this problem than other flow models, especially for larger fin spacing. The more grid points are not necessarily able to obtain more accurate results. The choice of the appropriate flow model and the number of grid points may depend on experimental temperature data and reliable heat transfer coefficient. Finally, it is found that the heat transfer coefficient increases with decreasing fin diameter and increasing fin spacing. Fin efficiency decreases with increasing fin diameter and fin spacing. The optimum fin spacing can vary with the D/d(0) value. Also, the proposed correlation between the Nusselt number and the Rayleigh number matches the inverse and numerical results obtained. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:483 / 496
页数:14
相关论文
共 50 条
  • [1] Numerical simulation of natural convection heat transfer for annular elliptical finned tube heat exchanger with experimental data
    Chen, Han-Taw
    Hsieh, Yi-Lun
    Chen, Ping-Chou
    Lin, Yi-Fan
    Liu, Kuo-Chi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 : 541 - 554
  • [2] Numerical and experimental study of natural convection heat transfer characteristics for vertical annular finned tube heat exchanger
    Chen, Han-Taw
    Chiu, Yu-Jie
    Liu, Chein-Shan
    Chang, Jiang-Ren
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 109 : 378 - 392
  • [3] Numerical study of mixed convection heat transfer for vertical annular finned tube heat exchanger with experimental data and different tube diameters
    Chen, Han-Taw
    Chang, Yao-Lun
    Lin, Pei-Yu
    Chiu, Yu-Jie
    Chang, Jiang-Ren
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 118 : 931 - 947
  • [4] Natural convection of plate finned tube heat exchangers with two horizontal tubes in a chimney: Experimental and numerical study
    Chen, Han-Taw
    Ma, Wei-Xuan
    Lin, Pei-Yu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 147
  • [5] Effect of domain boundary set on natural convection heat transfer characteristics for vertical annular finned tube heat exchanger
    Chen, Han-Taw
    Chiu, Yu-Jie
    Tseng, Hung-Chia
    Chang, Jiang-Ren
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 109 : 668 - 682
  • [6] Optimization of Horizontal Annular Finned Tube Under Natural Convection Heat Transfer
    Nemati, Hossain
    Ardekani, Mohammad Moghimi
    Cemal Benim, Ali
    Meyer, Josua
    HEAT TRANSFER ENGINEERING, 2022, 43 (17) : 1451 - 1463
  • [7] Experimental Study of Heat Transfer and Resistance on Finned Tube Exchanger
    Guo, Yajun
    Wang, Ming
    Liu, Guangcai
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 645 - 652
  • [8] The Correlation of Heat Transfer Coefficients for the Laminar Natural Convection in a Circular Finned-Tube Heat Exchanger
    Kang, Hie Chan
    Chang, Se-Myong
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2018, 140 (03):
  • [9] PARAMETRIC STUDY OF OPERATING AND GEOMETRY CHARACTERISTICS EFFECT ON HEAT TRANSFER IN ANNULAR FINNED TUBE HEAT EXCHANGER
    Sencic, Tomislav
    Trp, Anica
    Lenic, Kristian
    ENGINEERING REVIEW, 2009, 29 (01) : 25 - 36
  • [10] Numerical and Experimental Study of Finned Tube Heat Transfer Characteristics
    Petrik, Mate
    Szepesi, Gabor L.
    Varga, Tibor
    VEHICLE AND AUTOMOTIVE ENGINEERING 2, VAE2018, 2018, : 563 - 570