Simultaneous determination of bromate, chlorite and haloacetic acids by two-dimensional matrix elimination ion chromatography with coupled conventional and capillary columns

被引:33
|
作者
Teh, Hui Boon [1 ]
Li, Sam Fong Yau [1 ,2 ,3 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[2] NUS Environm Res Inst, Singapore 117411, Singapore
[3] Peking Univ, Shenzhen Grad Sch, Sch Environm & Energy, Shenzhen Engn Lab Ecoefficient Polysilicate Mat, Shenzhen 518055, Peoples R China
基金
新加坡国家研究基金会;
关键词
Bromate; Haloacetic acids; Ion-chromatography; Two-dimensional; Capillary; DRINKING-WATER; BY-PRODUCTS; TRICHLOROACETIC-ACID; DICHLOROACETIC ACID; MASS-SPECTROMETRY; CHLORINATION; OXYHALIDES; OZONATION; BROMIDE; LIVER;
D O I
10.1016/j.chroma.2015.01.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new, highly sensitive and reliable two-dimensional matrix elimination ion chromatography (IC) method was developed for simultaneous detection of bromate, chlorite and five haloacetic acids. This method combined the conventional IC in first dimension with capillary IC in the second dimension coupled with suppressed conductivity detection. The first dimension utilizes a high capacity column to partially resolve matrix from target analytes. By optimizing the cut window, the target analytes were selectively cut and trapped in a trap column through the use of a six-port valve, while the separated matrix were diverted to waste. The trapped target analytes were delivered on to the capillary column for further separation and detection. Temperature programming was used to improve selectivity in second dimension column to obtain complete resolution of the target analytes. Compared to the performance of one-dimensional IC, the two-dimensional approach resulted in a significant increase in sensitivity for all target analytes with limit of detection ranging from 0.30 to 0.64 mu g/L and provided more reliable analysis due to second column confirmation. Good linearity was obtained for all the target analytes with correlation coefficients >0.998. The proposed method was successfully applied to the determination of oxyhalides and haloacetic acids in various matrices with recoveries ranging from 90 to 116% and RSD less than 6.1%. The method allows direct injection of samples and the use of columns with different selectivity, thus significantly reduces the level of false positive results. The method is fully automated and simple, making it practical for routine monitoring of water quality. The satisfactory results also demonstrated that the two-dimensional matrix elimination method coupled with capillary IC is a promising approach for detection of trace substances in complex matrices. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 50 条
  • [31] DIRECT DETERMINATION OF ACRYLAMIDE IN A COMPLEX AQUEOUS MATRIX BY TWO-DIMENSIONAL LIQUID-CHROMATOGRAPHY
    FRESHOUR, NL
    LANGVARDT, PW
    FRANTZ, SW
    DRYZGA, MD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 190 (SEP): : 114 - ANL
  • [32] DETERMINATION OF DIETHYLENE GLYCOL MONOETHYL ETHER IN FLAVORS BY TWO-DIMENSIONAL CAPILLARY GAS-CHROMATOGRAPHY
    VANINGEN, RHM
    NIJSSEN, LM
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1989, 12 (07): : 484 - 485
  • [33] Two-Dimensional Separation of Ionic Species by Hyphenation of Capillary Ion Chromatography x Capillary Electrophoresis-Mass Spectrometry
    Beutner, Andrea
    Kochmann, Sven
    Mark, Jonas Josef Peter
    Matysik, Frank-Michael
    ANALYTICAL CHEMISTRY, 2015, 87 (06) : 3134 - 3138
  • [34] Two-dimensional ion chromatography using tandem ion-exchange columns with gradient-pulse column switching
    Johns, Cameron
    Shellie, Robert A.
    Pohl, Christopher A.
    Haddad, Paul R.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (41) : 6931 - 6937
  • [35] Determination of iodide, thiocyanate and perchlorate ions in environmental water by two-dimensional ion chromatography
    Lin Li
    Wang Haibo
    Shi Yali
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (03) : 281 - 285
  • [36] Determination of γ-hydroxybutyrate in human urine samples by ion exclusion and ion exchange two-dimensional chromatography system
    Liu, Junwei
    Deng, Zhifen
    Zhu, Zuoyi
    Wang, Yong
    Wang, Guoqing
    Sun, Yu-an
    Zhu, Yan
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1528 : 35 - 40
  • [37] Two-dimensional capillary liquid chromatography: pH Gradient ion exchange and reversed phase chromatography for rapid separation of proteins
    Pepaj, Milaim
    Wilson, Steven R.
    Novotna, Katerina
    Lundanes, Elsa
    Greibrokk, Tyge
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1120 (1-2) : 132 - 141
  • [38] In Silico Screening of Two-Dimensional Separation Selectivity for Ion Chromatography x Capillary Electrophoresis Separation of Low-Molecular-Mass Organic Acids
    Ranjbar, Leila
    Talebi, Mohammad
    Haddad, Paul R.
    Park, Soo Hyun
    Cabot, Joan M.
    Zhang, Min
    Smejkal, Petr
    Foley, Joe P.
    Breadmore, Michael C.
    ANALYTICAL CHEMISTRY, 2017, 89 (17) : 8808 - 8815
  • [39] Separation of phenolic acids and flavone natural antioxidants by two-dimensional method combining liquid chromatography and micellar electrokinetic capillary chromatography
    Cesla, Petr
    Fischer, Jan
    Jandera, Pavel
    ELECTROPHORESIS, 2010, 31 (13) : 2200 - 2210
  • [40] Ion-Exchange Chromatography Coupled With Dynamic Coating Capillary Electrophoresis for Simultaneous Determination of Tropomyosin and Arginine Kinase in Shellfish
    Fu, Linglin
    Zhou, Jinru
    Wang, Chong
    Li, Xiaohui
    Zheng, Lei
    Wang, Yanbo
    FRONTIERS IN CHEMISTRY, 2018, 6