Electrochemical nucleic acid biosensors for the detection of interaction between peroxynitrite and DNA

被引:6
|
作者
de la Fuente, Elizabeth [1 ]
Villagra, Gonzalo [1 ]
Bollo, Soledad [1 ]
机构
[1] Univ Chile, Fac Ciencias Quim & Farmaceut, Lab Bioelectroquim, Santiago, Chile
关键词
DNA damage; peroxynitrite; carbon paste electrode; biosensors;
D O I
10.1002/elan.200703885
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We studied the reactivity of peroxynitrite and different nucleic acid molecules using DNA electrochemical biosensors. SIN-1 (3-morpholinosydnonimine) has been used for the simultaneous generation of NO- and superoxide, i.e., as a peroxynitrite (ONOO-) donor. Double strand DNA (dsDNA), single strand DNA (ssDNA) and 15 guanine bases oligonucleotide (Oligo(dG)(15)) were immobilized on a carbon paste electrode to generate the biosensor and DPV was selected as the electroanalytical technique. Results showed that electrochemical biosensors were very sensitive for detecting interaction between ONOO- and DNA. A down/up effect was observed, i.e., at low ONOO- concentrations the guanine oxidation signal decreased while at high ONOO- concentrations the guanine oxidation current increased. Oligo(dG)15 exhibited greater interaction at low ONOO- concentrations than the other DNA molecules. The reactivity between ONOO- and DNA was also evaluated in solution phase, showing the same down/up effect. Finally, the capacity of DNA to hybridize was prevented after interaction with ONOO-.
引用
收藏
页码:1518 / 1523
页数:6
相关论文
共 50 条
  • [31] In situ electrochemical investigation of the interaction between bacteria Xylella fastidiosa DNA and copper(II) using DNA-electrochemical biosensors
    Machini, W. B. S.
    Oliveira-Brett, A. M.
    ELECTROCHEMISTRY COMMUNICATIONS, 2021, 125
  • [32] Analysis of the evolution of the detection limits of electrochemical DNA biosensors
    Lazerges, Mathieu
    Bedioui, Fethi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (11) : 3705 - 3714
  • [33] CRISPR/Cas-based Biosensors for Nucleic Acid Detection
    Chen, Si
    Lin, Yu-kun
    Song, Chun-yan
    Zhi, Shuai
    Li, Yi
    Yang, Dan-ting
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2023, 50 (08) : 1782 - 1796
  • [34] Resonant cavity optical biosensors for the detection of nucleic acid hybridization
    Airola, M
    Blair, S
    Chen, Y
    Davis, J
    Williams, L
    CLINICAL DIAGNOSTIC SYSTEMS: TECHNOLOGIES AND INSTRUMENTATION, 2002, 4625 : 29 - 37
  • [35] A Short Review on Miniaturized Biosensors for the Detection of Nucleic Acid Biomarkers
    Kulkarni, Madhusudan B.
    Ayachit, Narasimha H.
    Aminabhavi, Tejraj M.
    BIOSENSORS-BASEL, 2023, 13 (03):
  • [36] Recent Progresses in Electrochemical DNA Biosensors for MicroRNA Detection
    Lulu Zhang
    Wenqiong Su
    Shuopeng Liu
    Chengjie Huang
    Behafarid Ghalandari
    Adeleh Divsalar
    Xianting Ding
    Phenomics, 2022, 2 : 18 - 32
  • [37] Advances in the Functional Nucleic Acid Biosensors for Detection of Lead Ions
    Zhang, Bu-yue
    Shi, Lei
    Ma, Xiao-ying
    Liu, Lu
    Fu, Yao
    Zhang, Xiu-feng
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2023, 53 (02) : 309 - 325
  • [38] Electrochemical biosensors for sequence-specific DNA detection
    Rivas, GA
    Pedano, ML
    Ferreyra, NF
    ANALYTICAL LETTERS, 2005, 38 (15) : 2653 - 2703
  • [39] Analysis of the evolution of the detection limits of electrochemical DNA biosensors
    Mathieu Lazerges
    Fethi Bedioui
    Analytical and Bioanalytical Chemistry, 2013, 405 : 3705 - 3714
  • [40] Electrochemical genosensor for the detection of interaction between methylene blue and DNA
    Kara, P
    Kerman, K
    Ozkan, D
    Meric, B
    Erdem, A
    Ozkan, Z
    Ozsoz, M
    ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (09) : 705 - 709