MRI-Assisted PET Motion Correction for Neurologic Studies in an Integrated MR-PET Scanner

被引:131
|
作者
Catana, Ciprian [1 ,2 ]
Benner, Thomas [1 ,2 ]
van der Kouwe, Andre [1 ,2 ]
Byars, Larry
Hamm, Michael
Chonde, Daniel B. [1 ,2 ]
Michel, Christian J.
El Fakhri, Georges [3 ,4 ]
Schmand, Matthias
Sorensen, Gregory [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Athinoula A Marinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, Charlestown, MA USA
[3] Massachusetts Gen Hosp, Dept Radiol, Div Nucl Med & Mol Imaging, Boston, MA 02114 USA
[4] Harvard Univ, Sch Med, Boston, MA USA
关键词
PET; MRI; multimodality imaging; motion tracking; motion correction; POSITRON-EMISSION-TOMOGRAPHY; SENSITIVITY IMAGE; MODE; TRACKING; IMPLEMENTATION; NORMALIZATION; ALGORITHM; SCHEME;
D O I
10.2967/jnumed.110.079343
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MRI data can be used for motion tracking. In this work, a novel algorithm for data processing and rigid-body motion correction (MC) for the MRI-compatible BrainPET prototype scanner is described, and proof-of-principle phantom and human studies are presented. Methods: To account for motion, the PET prompt and random coincidences and sensitivity data for postnormalization were processed in the line-of-response (LOR) space according to the MRI-derived motion estimates. The processing time on the standard BrainPET workstation is approximately 16 s for each motion estimate. After rebinning in the sinogram space, the motion corrected data were summed, and the PET volume was reconstructed using the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed, and motion estimates were obtained using 2 high-temporal-resolution MRI-based motion-tracking techniques. Results: After accounting for the misalignment between the 2 scanners, perfectly coregistered MRI and PET volumes were reproducibly obtained. The MRI output gates inserted into the PET list-mode allow the temporal correlation of the 2 datasets within 0.2 ms. The Hoffman phantom volume reconstructed by processing the PET data in the LOR space was similar to the one obtained by processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the procedure. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 s and 20 ms, respectively. Motion-deblurred PET images, with excellent delineation of specific brain structures, were obtained using these 2 MRI-based estimates. Conclusion: An MRI-based MC algorithm was implemented for an integrated MR-PET scanner. High-temporal-resolution MRI-derived motion estimates (obtained while simultaneously acquiring anatomic or functional MRI data) can be used for PET MC. An MRI-based MC method has the potential to improve PET image quality, increasing its reliability, reproducibility, and quantitative accuracy, and to benefit many neurologic applications.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 50 条
  • [31] MR-BASED ATTENUATION MAP RE-ALIGNMENT AND MOTION CORRECTION IN SIMULTANEOUS BRAIN MR-PET IMAGING
    Sforazzini, Francesco
    Chen, Zhaolin
    Baran, Jakub
    Bradley, Jason
    Carey, Alexandra
    Shah, N. Jon
    Egan, Gary
    2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, : 231 - 234
  • [32] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Vontobel, Jan
    Liga, Riccardo
    Possner, Mathias
    Clerc, Olivier F.
    Mikulicic, Fran
    Veit-Haibach, Patrick
    ter Voert, Edwin E. G. W.
    Fuchs, Tobias A.
    Stehli, Julia
    Pazhenkottil, Aju P.
    Benz, Dominik C.
    Graeni, Christoph
    Gaemperli, Oliver
    Herzog, Bernhard
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (10) : 1574 - 1580
  • [33] Examination of the absorption correction for the 3D MR-PET Imaging
    Yamada, M.
    Yamagishi, M.
    Hirano, M.
    Watanabe, S.
    Kikuta, D.
    Ito, K.
    Seto, A.
    Imabayashi, E.
    Kuji, I.
    Ito, K.
    Matsuda, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S478 - S479
  • [34] MRI Coil Development Strategies for Hybrid MR-PET Systems: A Review
    Choi, Chang-Hoon
    Felder, Joerg
    Lerche, Christoph
    Shah, N. Jon
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2024, 17 : 342 - 350
  • [35] The optimization of the absorption correction for the 3D MR-PET Imaging
    Yamada, M.
    Yamagishi, M.
    Hirano, M.
    Kikuta, D.
    Hirai, M.
    Kawamura, Y.
    Ohnuki, K.
    Haruta, H.
    Takizawa, O.
    Shimano, Y.
    Ito, K.
    Seto, A.
    Imabayashi, E.
    Kuji, I.
    Matsuda, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S487 - S487
  • [36] Extended MRI-based PET motion correction for cardiac PET/MRI
    Aizaz, Mueez
    van der Pol, Jochem A. J.
    Schneider, Alina
    Munoz, Camila
    Holtackers, Robert J.
    van Cauteren, Yvonne
    van Langen, Herman
    Meeder, Joan G.
    Rahel, Braim M.
    Wierts, Roel
    Botnar, Rene M.
    Prieto, Claudia
    Moonen, Rik P. M.
    Kooi, M. Eline
    EJNMMI PHYSICS, 2024, 11 (01)
  • [37] Extended MRI-based PET motion correction for cardiac PET/MRI
    Mueez Aizaz
    Jochem A. J. van der Pol
    Alina Schneider
    Camila Munoz
    Robert J. Holtackers
    Yvonne van Cauteren
    Herman van Langen
    Joan G. Meeder
    Braim M. Rahel
    Roel Wierts
    René M. Botnar
    Claudia Prieto
    Rik P. M. Moonen
    M. Eline Kooi
    EJNMMI Physics, 11
  • [38] A method for estimating the attenuation correction for the MR hardware of an MR/PET scanner
    Eldib, Mootaz
    Faul, David
    Ladebeck, Ralf
    Pawlak, John
    Doshi, Niraj
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [39] Value of a Dixon based MR-PET attenuation correction sequence for the localization and evaluation of PET positive lesions
    Eiber, Matthias
    Martinez-Moeller, Axel
    Souvatzoglou, Michael
    Rummeny, Ernst
    Schwaiger, Markus
    Beer, Ambros
    Nekolla, Stephan
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [40] PET reconstruction strategies for motion correction in coronary PET/MR imaging
    Soultanidis, Georgios
    Karakatsanis, Nicolas
    Yang, Yang
    Robson, Philip
    Fayad, Zahi
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60