The dosimetric impact of leaf interdigitation and leaf width on VMAT treatment planning in Pinnacle: comparing Pareto fronts

被引:19
|
作者
van Kesteren, Z. [1 ,2 ]
Janssen, T. M. [1 ]
Damen, E. [1 ]
van Vliet-Vroegindeweij, C. [1 ]
机构
[1] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Radiat Oncol, NL-1105 AZ Amsterdam, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 10期
关键词
MODULATED RADIATION-THERAPY; STEREOTACTIC RADIOSURGERY; DOSE DISTRIBUTIONS; DELIVERY; IMRT;
D O I
10.1088/0031-9155/57/10/2943
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To evaluate in an objective way the effect of leaf interdigitation and leaf width on volumetric modulated arc therapy plans in Pinnacle. Three multileaf collimators (MLCs) were modeled: two 10 mm leaf width MLCs, with and without interdigitating leafs, and a 5 mm leaf width MLC with interdigitating leafs. Three rectum patients and three prostate patients were used for the planning study. In order to compare treatment techniques in an objective way, a Pareto front comparison was carried out. 200 plans were generated in an automated way, per patient per MLC model, resulting in a total of 3600 plans. From these plans, Pareto-optimal plans were selected which were evaluated for various dosimetric variables. The capability of leaf interdigitation showed little dosimetric impact on the treatment plans, when comparing the 10 mm leaf width MLC with and without leaf interdigitation. When comparing the 10 mm leaf width MLC with the 5 mm leaf width MLC, both with interdigitating leafs, improvement in plan quality was observed. For both patient groups, the integral dose was reduced by 0.6 J for the thin MLC. For the prostate patients, the mean dose to the anal sphincter was reduced by 1.8 Gy and the conformity of the V-95% was reduced by 0.02 using the thin MLC. The V-65% of the rectum was reduced by 0.1% and the dose homogeneity with 1.5%. For rectum patients, the mean dose to the bowel was reduced by 1.4 Gy and the mean dose to the bladder with 0.8 Gy for the thin MLC. The conformity of the V95% was equivalent for the 10 and 5 mm leaf width MLCs for the rectum patients. We have objectively compared three types of MLCs in a planning study for prostate and rectum patients by analyzing Pareto-optimal plans which were generated in an automated way. Interdigitation of MLC leafs does not generate better plans using the SmartArc algorithm in Pinnacle. Changing the MLC leaf width from 10 to 5 mm generates better treatment plans although the clinical relevance remains to be proven.
引用
收藏
页码:2943 / 2952
页数:10
相关论文
共 50 条
  • [21] Dosimetric impact of leaf open time and other planning parameters on DQA in helical tomotherapy
    Chang, K. H.
    Jung, D. M.
    Hong, C.
    Han, M.
    Kim, J.
    Han, S. C.
    Lee, H.
    Park, K.
    Kim, D. W.
    Cho, J.
    Kim, Y. B.
    Kim, J. S.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S723 - S723
  • [22] Dosimetric study using different leaf-width MLCs for treatment planning of dynamic conformal arcs and intensity-modulated radiosurgery
    Jin, JY
    Yin, FF
    Ryu, S
    Ajlouni, M
    Kim, JH
    MEDICAL PHYSICS, 2005, 32 (02) : 405 - 411
  • [23] On the need for tuning the dosimetric leaf gap for stereotactic treatment plans in the Eclipse treatment planning system
    Vieillevigne, Laure
    Khamphan, Catherine
    Saez, Jordi
    Hernandez, Victor
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (07): : 68 - 77
  • [24] Dosimetric Impact of Multileaf Collimator Leaf Width On Stereotactic Radiosurgery (SRS) RapidArc Treatment Plans for Single and Multiple Brain Metastases
    Hossain, S.
    Keeling, V.
    Ahmad, S.
    Algan, O.
    MEDICAL PHYSICS, 2015, 42 (06) : 3409 - 3409
  • [25] Dosimetric Impact of Multileaf Collimator Leaf Width On Single and Multiple Isocenter Stereotactic IMRT Treatment Plans for Multiple Brain Tumors
    Giem, J.
    Algan, O.
    Ahmad, S.
    Ali, I.
    Young, J.
    Hossain, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 324 - 324
  • [26] Dosimetric Impact of AAA and AXB Dose Calculation Algorithm in VMAT Treatment Planning for Rectal Tumors
    Srinivasan, Karthikeyan
    Sekaran, Sureka Chandrasekaran
    Thangavelu, Suresh
    Belliappa, M. S.
    JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) : 86 - 92
  • [27] Quantitative dosimetric study using different leaf-width multileaf collimators for treatment planning of dynamic conformal and intensity-modulated radiosurgery
    Jin, J
    Yin, F
    Ryu, S
    Ajlouni, M
    Kim, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S641 - S641
  • [28] Dosimetric Impact of Multileaf Collimator Leaf Width On Single and Multiple Isocenter Stereotactactic IMRT Treatment Plans for Four Or More Intracranial Tumors
    Kendall, E.
    Algan, O.
    Ali, I.
    Arntzen, J.
    Ahmad, S.
    Hossain, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3600 - 3600
  • [29] Effects of the dosimetric leaf gap in treatment planning system on the agreement between predicted and measured doses
    Cui, Congwu
    Wu, Xia
    MEDICAL PHYSICS, 2017, 44 (08) : 4389 - 4389
  • [30] Effect of MLC leaf width on the planning and delivery of SMLC IMRT using the CORVUS inverse treatment planning system
    Burmeister, J
    McDermott, PN
    Bossenberger, T
    Ben-Josef, E
    Levin, K
    Forman, JD
    MEDICAL PHYSICS, 2004, 31 (12) : 3187 - 3193