Kinetic Model of Gas-Liquid-Liquid Reactive Extraction for Production of Hydrogen Peroxide

被引:10
|
作者
Lu, Shuxiang [1 ]
Wang, Li [2 ]
Wang, Yaquan [2 ]
Mi, Zhentao [2 ]
机构
[1] Tianjin Univ Sci & Technol, Sch Mat Sci & Chem Engn, Tianjin 300457, Peoples R China
[2] Tianjin Univ, Sch Chem Engn & Technol, State Educ Minist, Key Lab Green Chem Technol, Tianjin 300072, Peoples R China
关键词
Anthraquinone; Extraction; Hydrogen peroxide; Kinetics; Mass transfer; Multiphase reactions; ANTHRAQUINONE; SEPARATIONS; SIMULATION; OXIDATION; DESIGN;
D O I
10.1002/ceat.201000094
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The kinetic aspects of the gas-liquid-liquid reactive extraction process for the production of hydrogen peroxide were investigated in a batch reactor. It was observed that the gas-liquid reaction rate is strongly affected by mass transfer of oxygen across the liquid film and the reaction can be simplified to pseudo-first order. The extraction rate is governed by both reaction and liquid-liquid mass transfer, and is slightly lower than the reaction rate. In addition, a kinetic model of the reactive extraction process for the production of hydrogen peroxide was developed. Kinetic parameters under different conditions were determined by experiments. The data calculated from the kinetic model match experimental data well under different conditions for hydrogen peroxide production in gas-liquid-liquid reactive extraction.
引用
收藏
页码:823 / 830
页数:8
相关论文
共 50 条
  • [21] Reactive extraction for production of hydrogen peroxide under pressure
    Cheng, Yongxi
    Li, Hongtao
    Lu, Shuxiang
    Wang, Li
    Shiyou Huagong/Petrochemical Technology, 2007, 36 (01): : 49 - 54
  • [22] Production and transport of plasma-generated hydrogen peroxide from gas to liquid
    Schuettler, Steffen
    Schoene, Anna Lena
    Jess, Emanuel
    Gibson, Andrew R.
    Golda, Judith
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2024, 26 (10) : 8255 - 8272
  • [23] The inversion of liquid phases during gas-liquid-liquid three phase flow
    Witczak, S
    Troniewski, L
    Dyga, R
    Pendyk, B
    INZYNIERIA CHEMICZNA I PROCESOWA, 2004, 25 (03): : 1801 - 1806
  • [24] Carbon Dioxide Mass Transfer in Gas-Liquid-Liquid System
    Garcia-Abuin, Alicia
    Gomez-Diaz, Diego
    Navaza, Jose M.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2012, 51 (15) : 5585 - 5591
  • [25] Varying porosity kinetic model for direct and reactive solid-liquid extraction
    Seikova, I.
    Mintchev, A.
    Hungarian Journal of Industrial Chemistry, 2002, 30 (02): : 95 - 101
  • [26] Gammas and X-ray tomography of liquid-liquid and gas-liquid-liquid flows
    Department of Chemical Engineering, Imperial College London, London SW7 2BY, United Kingdom
    不详
    Multiph Sci Technol, 2007, 3 (241-267):
  • [27] Modeling investigation of mass transfer of gas-liquid-liquid dispersion systems
    Tan, J.
    Lu, Y. C.
    Xu, J. H.
    Luo, G. S.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 108 : 111 - 118
  • [28] An electrically driven gas-liquid-liquid contactor for bioreactor and other applications
    Tsouris, C
    Borole, AP
    Kaufman, EN
    DePaoli, DW
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (05) : 1877 - 1883
  • [29] Detailed investigation of multiphase (gas-liquid and gas-liquid-liquid) flow behaviour on inclined plates
    Hoffmann, A
    Ausner, I
    Repke, JU
    Wozny, G
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2006, 84 (A2): : 147 - 154
  • [30] Intensification of high-phase-ratio extraction via microbubble-agitation in gas-liquid-liquid systems
    Feng, Ting-Fan
    Tan, Jing
    Deng, Wen-Sheng
    Su, Yue-Feng
    CHEMICAL ENGINEERING SCIENCE, 2018, 177 : 270 - 283