Retrospective Correction of Physiological Field Fluctuations in High-Field Brain MRI Using Concurrent Field Monitoring

被引:64
|
作者
Vannesjo, S. Johanna [1 ]
Wilm, Bertram J. [1 ]
Duerst, Yolanda [1 ]
Gross, Simon [1 ]
Brunner, David O. [1 ]
Dietrich, Benjamin E. [1 ]
Schmid, Thomas
Barmet, Christoph [1 ,2 ]
Pruessmann, Klaas P. [1 ]
机构
[1] Univ & ETH Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] Skope Magnet Resonance Technol, Zurich, Switzerland
关键词
physiological noise; field fluctuations; T2*-weighted imaging; concurrent field monitoring; magnetic field monitoring; GRADIENT SYSTEM CHARACTERIZATION; ECHO-PLANAR; RECONSTRUCTION; RESPIRATION; MOTION; NOISE;
D O I
10.1002/mrm.25303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeMagnetic field fluctuations caused by subject motion, such as breathing or limb motion, can degrade image quality in brain MRI, especially at high field strengths. The purpose of this study was to investigate the feasibility of retrospectively correcting for such physiological field perturbations based on concurrent field monitoring. Theory and MethodsHigh-resolution T2*-weighted gradient-echo images of the brain were acquired at 7T with subjects performing different breathing and hand movement patterns. Field monitoring with a set of F-19 NMR probes distributed around the head was performed in two variants: concurrently with imaging or as a single field measurement per readout. The measured field fluctuations were then accounted for in the image reconstruction. ResultsSignificant field fluctuations due to motion were observed in all subjects, resulting in severe artifacts in uncorrected images. The artifacts were largely removed by reconstruction based on field monitoring. Accounting for field perturbations up to the 1st spatial order was generally sufficient to recover good image quality. ConclusionsIt has been demonstrated that artifacts due to physiologically induced dynamic field perturbations can be greatly reduced by retrospective image correction based on field monitoring. The necessity to perform such correction is greatest at high fields and for field-sensitive techniques such as T2*-weighted imaging. Magn Reson Med 73:1833-1843, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1833 / 1843
页数:11
相关论文
共 50 条
  • [31] HIGH-FIELD MRI OF HEMORRHAGIC CORTICAL INFARCTION
    HECHTLEAVITT, C
    GOMORI, JM
    GROSSMAN, RI
    GOLDBERG, HI
    HACKNEY, DB
    ZIMMERMAN, RA
    BILANIUK, LT
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1986, 7 (04) : 581 - 585
  • [32] High-field MRI studies on laboratory animals
    Sbarbati, A
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 : 288 - 289
  • [33] Multishot PROPELLER for High-Field Preclinical MRI
    Pandit, Prachi
    Qi, Yi
    Story, Jennifer
    King, Kevin F.
    Johnson, G. Allan
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (01) : 47 - 53
  • [34] TUMOR RESECTION IN THE HIGH-FIELD INTRAOPERATIVE MRI
    Hoover, Jason M.
    Goerss, Stephan J.
    Kaufmann, Timothy J.
    Meyer, Fredric B.
    Parney, Ian F.
    NEURO-ONCOLOGY, 2011, 13 : 162 - 162
  • [35] Correction of parallel transmission using concurrent RF and gradient field monitoring
    Mustafa Çavuşoğlu
    Benjamin Emanuel Dietrich
    David Otto Brunner
    Markus Weiger
    Klaas Paul Pruessmann
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 473 - 488
  • [36] Correction of parallel transmission using concurrent RF and gradient field monitoring
    Cavusoglu, Mustafa
    Dietrich, Benjamin Emanuel
    Brunner, David Otto
    Weiger, Markus
    Pruessmann, Klaas Paul
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (05) : 473 - 488
  • [37] Detecting breast microcalcifications with high-field MRI
    de Leeuw, Hendrik
    Stehouwer, Bertine L.
    Bakker, Chris J. G.
    Klomp, Dennis W. J.
    van Diest, Paul J.
    Luijten, Peter R.
    Seevinck, Peter R.
    van den Bosch, Maurice A. A. J.
    Viergever, Max A.
    Veldhuis, Wouter B.
    NMR IN BIOMEDICINE, 2014, 27 (05) : 539 - 546
  • [38] HIGH-FIELD MRI OF PRIMARY GALLBLADDER CARCINOMA
    WILBUR, AC
    GYI, B
    RENIGERS, SA
    GASTROINTESTINAL RADIOLOGY, 1988, 13 (02): : 142 - 144
  • [39] High-Field MRI Advantages and Applications in Rheumatology
    Cheng, Karen Y.
    Jerban, Saeed
    Bae, Won C.
    Fliszar, Evelyne
    Chung, Christine B.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2024, 62 (05) : 837 - 847
  • [40] Heating of Coils and Parts in High-field MRI
    Murphy-Boesch, Joseph
    EMAGRES, 2020, 9 (01): : 7 - 19