Retrospective Correction of Physiological Field Fluctuations in High-Field Brain MRI Using Concurrent Field Monitoring

被引:64
|
作者
Vannesjo, S. Johanna [1 ]
Wilm, Bertram J. [1 ]
Duerst, Yolanda [1 ]
Gross, Simon [1 ]
Brunner, David O. [1 ]
Dietrich, Benjamin E. [1 ]
Schmid, Thomas
Barmet, Christoph [1 ,2 ]
Pruessmann, Klaas P. [1 ]
机构
[1] Univ & ETH Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] Skope Magnet Resonance Technol, Zurich, Switzerland
关键词
physiological noise; field fluctuations; T2*-weighted imaging; concurrent field monitoring; magnetic field monitoring; GRADIENT SYSTEM CHARACTERIZATION; ECHO-PLANAR; RECONSTRUCTION; RESPIRATION; MOTION; NOISE;
D O I
10.1002/mrm.25303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeMagnetic field fluctuations caused by subject motion, such as breathing or limb motion, can degrade image quality in brain MRI, especially at high field strengths. The purpose of this study was to investigate the feasibility of retrospectively correcting for such physiological field perturbations based on concurrent field monitoring. Theory and MethodsHigh-resolution T2*-weighted gradient-echo images of the brain were acquired at 7T with subjects performing different breathing and hand movement patterns. Field monitoring with a set of F-19 NMR probes distributed around the head was performed in two variants: concurrently with imaging or as a single field measurement per readout. The measured field fluctuations were then accounted for in the image reconstruction. ResultsSignificant field fluctuations due to motion were observed in all subjects, resulting in severe artifacts in uncorrected images. The artifacts were largely removed by reconstruction based on field monitoring. Accounting for field perturbations up to the 1st spatial order was generally sufficient to recover good image quality. ConclusionsIt has been demonstrated that artifacts due to physiologically induced dynamic field perturbations can be greatly reduced by retrospective image correction based on field monitoring. The necessity to perform such correction is greatest at high fields and for field-sensitive techniques such as T2*-weighted imaging. Magn Reson Med 73:1833-1843, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1833 / 1843
页数:11
相关论文
共 50 条
  • [1] High-field MRI of brain activation and connectivity
    Chen, JH
    Chen, H
    Yen, CT
    CHINESE JOURNAL OF PHYSICS, 2004, 42 (04) : 520 - 525
  • [2] High-field MRI
    Cunningham, Patricia M.
    Law, Meng
    Schweitzer, Mark E.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2006, 37 (03) : 321 - +
  • [3] Analysis and correction of field fluctuations in fMRI data using field monitoring
    Bollmann, Saskia
    Kasper, Lars
    Vannesjo, S. Johanna
    Diaconescu, Andreea O.
    Dietrich, Benjamin E.
    Gross, Simon
    Stephan, Klaas E.
    Pruessmann, Klaas P.
    NEUROIMAGE, 2017, 154 : 92 - 105
  • [4] Environmental studies using high-field MRI
    Kaufmann, J
    Klippel, N
    Link, J
    Schenker, K
    INSIGHT, 1998, 40 (03) : 190 - 191
  • [5] Environmental studies using high-field MRI
    Kaufmann, J.
    Klippel, N.
    Link, J.
    Schenker, K.
    Insight: Non-Destructive Testing and Condition Monitoring, 1998, 40 (03): : 190 - 191
  • [6] Advances in High-Field MRI
    Hespel, Adrien-Maxence
    Cole, Robert C.
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2018, 48 (01) : 11 - +
  • [7] Prospect of High-Field MRI
    Wada, Hitoshi
    Sekino, Masaki
    Ohsaki, Hiroyuki
    Hisatsune, Tatsuhiro
    Ikehira, Hiroo
    Kiyoshi, Tsukasa
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 115 - 122
  • [8] The Safety of High-Field MRI?
    Yilmaz, S.
    INTERNATIONAL JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2014, 5 (02): : 63 - 64
  • [9] HIGH-FIELD MAGNETIC FLUCTUATIONS IN LASRCUO
    JANOSSY, B
    FRUCHTER, L
    CAMPBELL, IA
    SANCHEZ, J
    TANAKA, I
    KOJIMA, H
    SOLID STATE COMMUNICATIONS, 1994, 89 (05) : 433 - 436
  • [10] Study of brain anatomy with high-field MRI: recent progress
    Duyn, Jozef H.
    MAGNETIC RESONANCE IMAGING, 2010, 28 (08) : 1210 - 1215