Non-Newtonian blood flow study in a model cavopulmonary vascular system

被引:9
|
作者
Chitra, K. [1 ]
Sundararajan, T. [2 ]
Vengadesan, S. [1 ]
Nithiarasu, P. [3 ]
机构
[1] Indian Inst Technol, Dept Appl Mech, Madras 600036, Tamil Nadu, India
[2] Indian Inst Technol, Dept Mech Engn, Madras 600036, Tamil Nadu, India
[3] Swansea Univ, Sch Engn, Swansea SA2 8PP, W Glam, Wales
基金
英国工程与自然科学研究理事会;
关键词
wall shear stress; haemodynamics; shear thinning; TCPC; finite element; recirculation zone; FONTAN OPERATIONS; FLUID-MECHANICS; FINITE-ELEMENT; ARTERIAL-WALL; CONNECTION; ATRIOPULMONARY; HEMODYNAMICS; SIMULATION; HEART;
D O I
10.1002/fld.2256
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A transient haemodynamic study in a model cavopulmonary vascular system has been carried out for a typical range of parameters using a finite element-based Navier-Stokes solver. The focus of this study is to investigate the influence of non-Newtonian behaviour of the blood on the haemodynamic quantities, such as wall shear stress (WSS) and flow pattern. The computational fluid dynamics (CFD) model is based on an artificial compressibility characteristic-based split (AC-CBS) scheme, which has been adopted to solve the Navier-Stokes equations in space-time domain. A power law model has been implemented to characterize the shear thinning nature of the blood depending on the local strain rate. Using the computational model, numerical investigations have been performed for Newtonian and non-Newtonian flows for different frequencies and input pulse forms. The haemodynamic quantities observed in total cavopulmonary connection (TCPC) for the above conditions suggest that there are considerable differences in average (about 25-40%) and peak (about 50%) WSS distributions, when the non-Newtonian behaviour of the blood is taken into account. The lower WSS levels observed for non-Newtonian cases point to the higher risk of lesion formation, especially at higher pulsation frequencies. A realistic pulse form is relatively safer than a sinusoidal pulse as it has more energy distributed in the higher harmonics, which results in higher average WSS values. The present study highlights the importance of including non-Newtonian shear thinning behaviour for modelling blood flow in the vicinity of repaired arterial connections. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:269 / 283
页数:15
相关论文
共 50 条
  • [41] An oscillating hydromagnetic non-Newtonian flow in a rotating system
    Hayat, T.
    Nadeem, S.
    Siddiqui, A.M.
    Asghar, S.
    Applied Mathematics Letters, 2004, 17 (06) : 609 - 614
  • [42] A NON-NEWTONIAN MODEL OF THE FLOW OF MUSH-ICE
    BRATANOW, T
    DEGRANDE, G
    APPLIED MATHEMATICAL MODELLING, 1982, 6 (05) : 331 - 337
  • [43] Concerning a Model of Flow of Non-Newtonian Systems.
    Minigazimov, M.G.
    1978, (05): : 55 - 59
  • [44] FLOW OF NON-NEWTONIAN FLUID
    THIRIET, M
    MARTINBORRET, G
    HECHT, F
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1995, 103 (03) : C151 - C151
  • [45] AN EQUATION FOR NON-NEWTONIAN FLOW
    SHANGRAW, R
    GRIM, W
    MATTOCKS, AM
    TRANSACTIONS OF THE SOCIETY OF RHEOLOGY, 1961, 5 : 247 - 260
  • [46] Flow of a non-Newtonian fluid
    V. G. Pridanov
    V. I. Khonichev
    Technical Physics, 2012, 57 : 1475 - 1478
  • [47] A cell-based smoothed finite element model for non-Newtonian blood flow
    Liu, Mingyang
    Gao, Guangjun
    Khoo, Boo Cheong
    He, Zhenhu
    Jiang, Chen
    APPLIED MATHEMATICS AND COMPUTATION, 2022, 435
  • [48] INSTABILITY IN NON-NEWTONIAN FLOW
    PEARSON, JRA
    ANNUAL REVIEW OF FLUID MECHANICS, 1976, 8 : 163 - 181
  • [49] CHARACTERIZATION OF NON-NEWTONIAN FLOW
    ROSEN, MR
    POLYMER-PLASTICS TECHNOLOGY AND ENGINEERING, 1979, 12 (01) : 1 - 42
  • [50] Passive tracer transport in peristaltic pumping of non-Newtonian blood flow: A mathematical model
    Beg, O. Anwar
    Roy, Ashis Kumar
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2023, 37 (30):