Impact of a Risk Management Plan on Legionella Contamination of Dental Unit Water

被引:38
|
作者
Leoni, Erica [1 ]
Dallolio, Laura [1 ]
Stagni, Francesca [2 ]
Sanna, Tiziana [3 ]
D'Alessandro, Giovanni [2 ]
Piana, Gabriela [2 ]
机构
[1] Univ Bologna, Dept Biomed & Neuromotor Sci, Unit Hyg Publ Hlth & Med Stat, I-40126 Bologna, Italy
[2] Univ Bologna, Dept Biomed & Neuromotor Sci, Unit Odontostomatol Sci, I-40125 Bologna, Italy
[3] Univ Bologna, Sch Hyg & Prevent Med, Dept Biomed & Neuromotor Sci, I-40126 Bologna, Italy
关键词
MICROBIAL BIOFILM FORMATION; PNEUMOPHILA CONTAMINATION; SYSTEMS; DISINFECTANTS; DECONTAMINATION; MULTICENTER; PREVALENCE; ANTIBODIES; INFECTION; SCHOOL;
D O I
10.3390/ijerph120302344
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study aimed to assess the prevalence of Legionella spp. in dental unit waterlines of a dental clinic and to verify whether the microbiological parameters used as indicators of water quality were correlated with Legionella contamination. A risk management plan was subsequently implemented in the dental health care setting, in order to verify whether the adopted disinfection protocols were effective in preventing Legionella colonization. The water delivered from syringes and turbines of 63 dental units operating in a dental clinic, was monitored for counts of the heterotrophic bacteria P. aeruginosa and Legionella spp. (22 degrees C and 37 degrees C). At baseline, output water from dental units continuously treated with disinfection products was more compliant with the recommended standards than untreated and periodically treated water. However, continuous disinfection was still not able to prevent contamination by Legionella and P. aeruginosa. Legionella was isolated from 36.4%, 24.3% and 53.3% of samples from untreated, periodically and continuously treated waterlines, respectively. The standard microbiological parameters used as indicators of water quality proved to be unreliable as predictors of the presence of Legionella, whose source was identified as the tap water used to supply the dental units. The adoption of control measures, including the use of deionized water in supplying the dental unit waterlines and the application of a combined protocol of continuous and periodic disinfection, with different active products for the different devices, resulted in good control of Legionella contamination. The efficacy of the measures adopted was mainly linked to the strict adherence to the planned protocols, which placed particular stress on staff training and ongoing environmental monitoring.
引用
收藏
页码:2344 / 2358
页数:15
相关论文
共 50 条
  • [21] Contamination of dental unit water lines (DUWL) with Legionella pneumophila and Pseudomonas aeruginosa; A Middle East systematic review and meta-analysis
    Khajezadeh, Masoud
    Mohseni, Fatemeh
    Khaledi, Azad
    Firoozeh, Arezoo
    EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY, 2022, 12 (04): : 93 - 99
  • [22] Microbial water quality management of dental unit water lines at a dental school
    Volgenant, C. M. C.
    Persoon, I. F.
    JOURNAL OF HOSPITAL INFECTION, 2019, 103 (01) : E115 - E117
  • [23] Legionella anisa, a possible indicator of water contamination by Legionella pneumophila
    van der Mee-Marquet, N
    Domelier, AS
    Arnault, L
    Bloc, D
    Laudat, P
    Hartemann, P
    Quentin, R
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (01) : 56 - 59
  • [24] Legionella spp. in dental unit waterlines
    Juraskova, Sedlata E.
    Sedlackova, H.
    Janska, J.
    Holy, O.
    Lalova, P.
    Matouskova, I
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2017, 118 (05): : 310 - 314
  • [25] Assessment of nosocomial bacterial contamination in dental unit waterlines: Impact of flushing
    Alkhulaifi, Manal M.
    Alotaibi, Dalal H.
    Alajlan, Hisham
    Binshoail, Thekra
    SAUDI DENTAL JOURNAL, 2020, 32 (02) : 68 - 73
  • [26] The frequency and extent of bacterial contamination of dental unit water systems in the Jerusalem
    Yahav, M
    Shapira, L
    Steinberg, D
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1103 - 1103
  • [27] CONTRIBUTION OF BIOFILM BACTERIA TO THE CONTAMINATION OF THE DENTAL UNIT WATER-SUPPLY
    WILLIAMS, HN
    BAER, ML
    KELLEY, JI
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1995, 126 (09): : 1255 - 1260
  • [28] Bacterial contamination of dental unit water lines in the Kildare and Wicklow areas
    Al-Ajami, H
    Eggleston, P
    Montague, J
    Niogain, A
    O'Connell, P
    O'Connor, D
    Sehmi, R
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 542 - 542
  • [29] Effect of water softening and heating on microbial contamination of dental unit systems
    Stampi, S
    Zanetti, F
    deLuca, G
    Romano, G
    Pistacchio, E
    Tonelli, E
    ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1996, 198 (06): : 522 - 530
  • [30] CONTAMINATION OF DENTAL UNIT COOLING WATER WITH ORAL MICROORGANISMS AND ITS PREVENTION
    BAGGA, BSR
    MURPHY, RA
    ANDERSON, AW
    PUNWANI, I
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1984, 109 (05): : 712 - 716