Exploring the performance of μSR position-sensitive detectors through numerical simulations

被引:1
|
作者
Shiroka, T. [1 ,2 ,3 ]
Scheuermann, R. [1 ]
Morenzoni, E. [1 ]
Stoykov, A. [1 ]
Prokscha, T. [1 ]
机构
[1] Paul Scherrer Inst, Lab Muon Spin Spect, CH-5232 Villigen, Switzerland
[2] Univ Parma, Dipartimento Fis, I-43100 Parma, Italy
[3] CNR, INFM, I-43100 Parma, Italy
关键词
position-sensitive detectors; computer modelling and simulation; GEANT4; muon spin rotation;
D O I
10.1016/j.nima.2008.03.079
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recently proposed improvements of the mu SR (muon spin rotation) technique include among others the use of position-sensitive detectors for the revelation of decay positrons. Unlike their high-energy particle counterparts, these detectors present specific peculiarities arising from the need of a relatively fast timing and from significant multiple scattering effects. By using advanced numerical simulation toolkits. such as GEANT4, we explore the expected detector performance and possible ways for its optimisation. Intrinsic limits, finite pixel size effects, as well as the many parameters influencing the detector behaviour (distance, extension, angles, etc.) were thoroughly analysed and quantified, thus providing a valuable guide in prototype building and testing. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:306 / 310
页数:5
相关论文
共 50 条
  • [41] A TEST OF NEW POSITION-SENSITIVE DETECTORS FOR SPEG
    VILLARI, ACC
    MITTIG, W
    BLUMENFELD, Y
    GILLIBERT, A
    GANGNANT, P
    GARREAU, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (01): : 240 - 242
  • [42] POSITION-SENSITIVE DETECTORS IN CONDENSED MATTER STUDIES
    ARNDT, UW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 459 - 462
  • [43] Electron emission channeling with position-sensitive detectors
    Wahl, U
    Correia, JG
    Cardoso, S
    Marques, JG
    Vantomme, A
    Langouche, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 136 : 744 - 750
  • [44] X-RAY POSITION-SENSITIVE DETECTORS
    ARNDT, UW
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1986, 19 : 145 - 163
  • [45] USE OF POSITION-SENSITIVE DETECTORS IN POSITRON IMAGING
    MUEHLLEHNER, G
    COLSHER, JG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 569 - 571
  • [46] TIMING RESPONSE OF SILICON POSITION-SENSITIVE DETECTORS
    BENNETT, SJ
    ENGLAND, JBA
    FREER, M
    FULTON, BR
    MURGATROYD, JT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 311 (1-2): : 105 - 112
  • [47] Position-sensitive low-temperature detectors
    Figueroa-Feliciano, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 496 - 501
  • [49] Performance evaluation of position-sensitive silicon detectors with four-corner readout
    Banu, A.
    Li, Y.
    McCleskey, M.
    Bullough, M.
    Walsh, S.
    Gagliardi, C. A.
    Trache, L.
    Tribble, R. E.
    Wilburn, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 593 (03): : 399 - 406
  • [50] Performance of the RENA-3 IC with Position-Sensitive CZT and CdTe Detectors
    Cajipe, Victoria B.
    Clajus, Martin
    Hayakawa, Satoshi
    Matteson, James L.
    Skelton, R. Thomas
    Turner, Tumay O.
    Volkovskii, Alexander
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5107 - +