Electrochemical detection of hydrocortisone using green-synthesized cobalt oxide nanoparticles with nafion-modified glassy carbon electrode

被引:27
|
作者
Sharma, Neha [1 ]
Reddy, Ankireddy Seshadri [2 ,3 ]
Yun, Kyusik [1 ]
机构
[1] Gachon Univ, Dept Bionanotechnol, Gyeonggi Do 13120, South Korea
[2] Gachon Univ, Dept Chem & Biol Engn, Seongnam 13120, Gyeonggi Do, South Korea
[3] Dr Buddollas Inst Life Sci, Dept Chem Sci, Tirupati 517503, Andhra Pradesh, India
基金
新加坡国家研究基金会;
关键词
Nigella sativa; Cobalt oxide; Nanoparticles; Nafion; Hydrocortisone; Electrochemical sensor; HIGH-PERFORMANCE; LIQUID-CHROMATOGRAPHY; CO3O4; NANOPARTICLES; TESTOSTERONE; CORTISOL; URINE; ASSAY;
D O I
10.1016/j.chemosphere.2021.131029
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Developing highly sensitive and selective sensors is important for the detection of steroid hormones. Electrochemical sensors are of great interest in this regard. Also utilization of bio-derived substances as an electrode material is environment friendly. In this study, we used green-synthesized cobalt oxide nanoparticles (CoO NPs) along with nafion (Naf) on a glassy carbon electrode to detect hydrocortisone (HC) by voltammetry. Electron microscopy, X-ray diffraction, Raman spectroscopy, ultraviolet-visible spectroscopy, X-ray photoelectron spectroscopy, and Fourier-transform infrared spectroscopy were used to characterize the CoO NPs prepared using Nigella sativa seeds extract. Cyclic voltammetry and differential pulse voltammetry was utilized for the detection of HC. Only one reduction peak at -0.5 V was observed in the presence of HC in 0.1 M sodium hydroxide, indicating an irreversible electrode process. The Naf-CoO NPs enhanced the active surface area of the glassy carbon electrode (GCE) that resulted in a good response for detecting HC with two linear ranges: 0.001-1 mu M and 1-9 mu M. In comparison to other published electrochemical sensors, the current sensor displayed a low limit of detection of 0.49 nM, as well as remarkable stability and reproducibility. The sensor exhibited credibility for the sensing of HC in pharmaceutical injections and blood serum samples with recovery percentages ranging from 97.7% to 102.5%. The electrochemical sensor has proved to be valuable for HC detection.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Electrochemical sensor for H2O2 using a glassy carbon electrode modified with a nanocomposite consisting of graphene oxide, cobalt(III) oxide, horseradish peroxidase and nafion
    Safi Asim Bin Asif
    Sher Bahadar Khan
    Abdullah M. Asiri
    Microchimica Acta, 2016, 183 : 3043 - 3052
  • [42] Electrochemical Determination of Neurotransmitters Using Gold Nanoparticles on Nafion/Carbon Paste Modified Electrode
    Atta, Nada F.
    Galal, Ahmed
    Azab, Shereen M.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2012, 159 (10) : H765 - H771
  • [43] Enhancing Dopamine Detection Using Glassy Carbon Electrode Modified with Graphene Oxide, Nickel and Gold Nanoparticles
    Hassine, Chedia Ben Ali
    Kahri, Hamza
    Barhoumi, Houcine
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
  • [44] Electrochemical detection of pyrosine with electrochemically reduced graphene oxide modified glassy carbon electrode
    Kong, Yong
    Ren, Xiaolin
    Huo, Zongli
    Wang, Guoxin
    Tao, Yongxin
    Yao, Chao
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2013, 236 (06) : 955 - 961
  • [45] Electrochemical detection of pyrosine with electrochemically reduced graphene oxide modified glassy carbon electrode
    Yong Kong
    Xiaolin Ren
    Zongli Huo
    Guoxin Wang
    Yongxin Tao
    Chao Yao
    European Food Research and Technology, 2013, 236 : 955 - 961
  • [46] Electrochemical oxidation of dobutamine on a magnesium oxide microflowers-nafion composite film modified glassy carbon electrode
    Ling, Yun-Yun
    Huang, Qin-An
    Feng, De-Xiang
    Li, Xiang-Zi
    Wei, Yan
    ANALYTICAL METHODS, 2013, 5 (18) : 4580 - 4584
  • [47] Electrochemical oxidation behavior of colchicine on a graphene oxide-Nafion composite film modified glassy carbon electrode
    Wang, Fei
    Zhou, Jing
    Liu, Yang
    Wu, ShengJiang
    Song, Ge
    Ye, Baoxian
    ANALYST, 2011, 136 (19) : 3943 - 3949
  • [48] Development of a new electrochemical sensor based on nafion/cobalt doped bismuth ferrite nanoparticle modified glassy carbon electrode for detection of hydrogen peroxide
    Alemayehu, Dagim
    Bitew, Zelalem
    Yohannes, Yonas Beyene
    SENSING AND BIO-SENSING RESEARCH, 2023, 42
  • [49] Electrochemical Detection of Bisphenol A Using Graphene-Modified Glassy Carbon Electrode
    Ntsendwana, B.
    Mamba, B. B.
    Sampath, S.
    Arotiba, O. A.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (04): : 3501 - 3512
  • [50] Amperometric Detection of Isoprenaline Based on Glassy Carbon Electrode Modified by Iridium Oxide Nanoparticles
    Roushani, Mahmoud
    Farokhi, Somayeh
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (05) : 1034 - 1042