Fluoroscopic images are degraded by scattering af x-rays from within the patient and by veiling glare in the image intensifier. Both of these degradations are well described by a response function applied to the primary intensity. If the response function is known, then an estimate of the primary component of the image can be computed by applying the inverse operation. However, the response function is actually variable, with dependence an such factors as patient thickness and imaging geometry. We describe a technique for estimating a parameterized response function so that a good estimate of the subject density profile can be recovered even if the response function parameters are not known in advance. Our method uses a partially absorbing filter with spatially varying density as a reference object which enables us to compute good estimates of the parameterized response function. We use simulated images to evaluate our method for a wide range of conditions. Our simulation results show that this technique can greatly reduce densitometric errors in fluoroscopic images.
引用
收藏
页码:668 / 674
页数:7
相关论文
共 50 条
  • [21] AUTOMATIC CLASSIFICATION OF MEDICAL X-RAY IMAGES
    Zare, Mohammad Reza
    Seng, Woo Chaw
    Mueen, Ahmed
    MALAYSIAN JOURNAL OF COMPUTER SCIENCE, 2013, 26 (01) : 9 - 22
  • [22] Automatic Tongue Tracking in X-Ray Images
    LUO Changwei
    LI Rui
    YU Lingyun
    YU Jun
    WANG Zengfu
    Chinese Journal of Electronics, 2015, 24 (04) : 767 - 771
  • [23] Automatic vertebra detection in X-ray images
    Moura, Daniel C.
    Correia, Miguel V.
    Barbosa, Jorge G.
    Reis, Ana M.
    Laranjeira, Manuel
    Gomes, Eusebio
    COMPUTATIONAL MODELLING OF OBJECTS REPRESENTED IN IMAGES: FUNDAMENTALS, METHODS AND APPLICATIONS, 2007, : 307 - +
  • [24] AUTOMATIC EVALUATION OF X-RAY AND ACOUSTIC IMAGES
    JACOBY, M
    MATERIALS EVALUATION, 1982, 40 (03) : A12 - A12
  • [25] Automatic Tongue Tracking in X-Ray Images
    Luo Changwei
    Li Rui
    Yu Lingyun
    Yu Jun
    Wang Zengfu
    CHINESE JOURNAL OF ELECTRONICS, 2015, 24 (04) : 767 - 771
  • [26] An analysis of scatter characteristics in x-ray CT spectral correction
    Zhang, Tao
    Chen, Zhiqiang
    Zhou, Hao
    Bennett, N. Robert
    Wang, Adam S.
    Gao, Hewei
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):
  • [27] An Analytical Approach to Correction for X-Ray Scatter in Heterogeneous Medium
    Yao, W.
    Leszczynski, K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2646 - +
  • [28] FAST AUTOMATED SEGMENTATION OF FEMORAL HEADS IN FLUOROSCOPIC X-RAY IMAGES
    Wang, Lei
    Kohnen, Michael
    Friman, Ola
    Hahn, Horst K.
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 984 - 988
  • [29] The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review
    Sayed, Mohammad
    Knapp, Karen M.
    Fulford, Jon
    Heales, Christine
    Alqahtani, Saeed J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 158
  • [30] Virtual scatter modulation for X-ray CT scatter correction using primary modulator
    Gao, Hewei
    Zhu, Lei
    Fahrig, Rebecca
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (06) : 869 - 885