Automatic correction of x-ray scatter and veiling glare in simulated fluoroscopic images

被引:2
|
作者
Close, RA [1 ]
Shah, KC [1 ]
Whiting, JS [1 ]
机构
[1] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
来源
PHYSICS OF MEDICAL IMAGING | 1998年 / 3336卷
关键词
fluoroscopy; x-ray scattering; veiling glare; convolution;
D O I
10.1117/12.317072
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fluoroscopic images are degraded by scattering af x-rays from within the patient and by veiling glare in the image intensifier. Both of these degradations are well described by a response function applied to the primary intensity. If the response function is known, then an estimate of the primary component of the image can be computed by applying the inverse operation. However, the response function is actually variable, with dependence an such factors as patient thickness and imaging geometry. We describe a technique for estimating a parameterized response function so that a good estimate of the subject density profile can be recovered even if the response function parameters are not known in advance. Our method uses a partially absorbing filter with spatially varying density as a reference object which enables us to compute good estimates of the parameterized response function. We use simulated images to evaluate our method for a wide range of conditions. Our simulation results show that this technique can greatly reduce densitometric errors in fluoroscopic images.
引用
收藏
页码:668 / 674
页数:7
相关论文
共 50 条
  • [1] Estimation of the x-ray scatter and veiling glare rate in coronarographic densitometric measurements
    Goszczynska, H
    Doria-Dernalowicz, J
    Purzycki, Z
    Leszczynski, L
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1714 - 1716
  • [2] Regularization method for scatter-glare correction in fluoroscopic images
    Close, RA
    Shah, KC
    Whiting, JS
    MEDICAL PHYSICS, 1999, 26 (09) : 1794 - 1801
  • [3] A Deep Learning-Based Scatter Correction of Simulated X-ray Images
    Lee, Heesin
    Lee, Joonwhoan
    ELECTRONICS, 2019, 8 (09)
  • [4] Experimental demonstration of automated scatter-glare correction in fluoroscopic images
    Close, RA
    Morioka, CA
    Whiting, JS
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 355 - 362
  • [5] Correction of veiling glare and scatter in cone-beam CT
    Baba, R
    Ueda, K
    Takagi, H
    RADIOLOGY, 1999, 213P : 453 - 453
  • [6] DETECTION AND CORRECTION OF GEOMETRICAL DISTORTION IN X-RAY FLUOROSCOPIC IMAGES
    WALLACE, WA
    JOHNSON, F
    JOURNAL OF BIOMECHANICS, 1981, 14 (02) : 123 - 125
  • [7] CHARACTERIZATION OF THE VEILING GLARE PSF IN X-RAY IMAGE INTENSIFIED FLUOROSCOPY
    SEIBERT, JA
    NALCIOGLU, O
    ROECK, WW
    MEDICAL PHYSICS, 1984, 11 (02) : 172 - 179
  • [8] Efficient automatic computation of veiling glare from scatter and ghosts by a simple modification to Monte-Carlo ray tracing
    Greynolds, Alan W.
    Proceedings of SPIE - The International Society for Optical Engineering, 2013, 8840
  • [9] Efficient automatic computation of veiling glare from scatter and ghosts by a simple modification to Monte-Carlo ray tracing
    Greynolds, Alan W.
    OPTICAL MODELING AND PERFORMANCE PREDICTIONS VI, 2013, 8840
  • [10] Independent component analysis for removing x-ray scatter in x-ray images
    Chen, Yen-Wei
    Han, Xianhua
    Oikawa, Shiro
    Fujita, Akinori
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 2327 - +