Personalized stent design for congenital heart defects using pulsatile blood flow simulations

被引:12
|
作者
Gundelwein, L. [1 ,2 ,4 ]
Miro, J. [3 ]
Barlatay, F. Gonzalez [3 ]
Lapierre, C. [3 ]
Rohr, K. [1 ,2 ]
Duong, L. [4 ]
机构
[1] Heidelberg Univ, BioQuant, IPMB, D-69120 Heidelberg, Germany
[2] DKFZ Heidelberg, Biomed Comp Vis Grp, D-69120 Heidelberg, Germany
[3] Ctr Hosp Univ St Justine, 3175 Chemin Cote St Catherine, Montreal, PQ H3T 1C5, Canada
[4] Ecole Technol Super, 1100 Notre Dame St W, Montreal, PQ H3C 1K3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Congenital heart defects; Mathematical models; Computational fluid dynamics; Pulmonary artery; Stent; OUTFLOW BOUNDARY-CONDITIONS; PULMONARY; HEMODYNAMICS; DEPLOYMENT; DISEASE; MRI;
D O I
10.1016/j.jbiomech.2018.09.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Stent size selection and placement are among the most challenging tasks in the treatment of pulmonary artery stenosis in congenital heart defects (CHD). Patient-specific 3D model from CT or MR improves the understanding of the patient's anatomy and information about the hemodynamics aid in patient risk assessment and treatment planning. This work presents a new approach for personalized stent design in pulmonary artery interventions combining personalized patient geometry and hemodynamic simulations. First, the stent position is initialized using a geometric approach. Second, the stent and artery expansion, including the foreshortening behavior of the stent is simulated. Two stent designs are considered, a regular stent and a Y-stent for bifurcations. Computational fluid dynamics (CFD) simulations of the blood flow in the initial and expanded artery models are performed using patient-specific boundary conditions in form of a pulsatile inflow waveform, 3-element Windkessel outflow conditions, and deformable vessel walls. The simulations have been applied to 16 patient cases with a large variability of anatomies. Finally, the simulations have been clinically validated using retrospective imaging from angiography and pressure measurements. The simulated pressure, volume flow and flow velocity values were on the same order of magnitude as the reference values obtained from clinical measurements, and the simulated stent placement showed a positive impact on the hemodynamic values. Simulation of geometric changes combined with CFD simulations offers the possibility to optimize stent type, size, and position by evaluating different configurations before the intervention, and eventually allow to test customized stent geometries and new deployment techniques in CHD. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 50 条
  • [31] Distribution of ABO Blood Groups among Patients with Congenital Heart Defects
    Anvari, Maryam Sotoudeh
    Naderan, Mohammad
    Shoar, Saeed
    Boroumand, Mohammad Ali
    Bina, Payvand
    JOURNAL OF PIONEERING MEDICAL SCIENCES, 2016, 6 (02): : 42 - 45
  • [32] EXPLORATION OF PULSATILE FLOW PATTERNS OF AORTIC BLOOD IN DOGS AND HUMANS AT HEART CATHETERIZATION
    RICHARDS, AM
    KUETHER, FW
    CIRCULATION, 1967, 36 (4S2) : I221 - &
  • [33] Echocardiograph pulmonary venous flow patterns in congenital heart defects with increased pulmonary flow
    Rivera, Ivan Romero
    Mendonca da Silva, Maria Alayde
    Moises, Valdir Ambrosio
    de Andrade, Jose Lazaro
    Campos Filho, Orlando
    de Paola, Angelo Amato
    Carvalho, Antonio Carlos
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2007, 88 (04) : 396 - 401
  • [34] Stent implantation in the ductus arteriosus for pulmonary blood supply in congenital heart disease
    Michel-Behnke, I
    Akintuerk, H
    Thul, J
    Bauer, J
    Hagel, KJ
    Schranz, D
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (02) : 242 - 252
  • [35] Fluid-structure interaction between pulsatile blood flow and a curved stented coronary artery on a beating heart: A four stent computational study
    Bukac, Martina
    Canic, Suncica
    Tambaca, Josip
    Wang, Yifan
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2019, 350 : 679 - 700
  • [36] Myocardial blood flow and coronary flow reserve in congenital heart defects with systemic right ventricles: Quantitative assessment with positron emission tomography
    Hauser, M
    Bengal, FM
    Kaemmerer, H
    Schwaiger, M
    Hess, J
    CIRCULATION, 2002, 106 (19) : 622 - 622
  • [37] FLOW-CONTROL IN AN ARTIFICIAL-HEART - THE DESIGN OF A MOTOR DRIVEN PULSATILE FLOW PUMP
    MABUCHI, K
    MORITA, M
    NISHIYAMA, K
    ITO, T
    ISHIHARA, A
    HASHIMOTO, S
    SASADA, T
    ARTIFICIAL ORGANS, 1981, 5 (03) : 313 - 313
  • [38] Scale-Resolving Simulations of Steady and Pulsatile Flow Through Healthy and Stenotic Heart Valves
    Hoeijmakers, M. J. M. M.
    Morgenthaler, V
    Rutten, M. C. M.
    van de Vosse, F. N.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (03):
  • [39] Pulsatile Blood Flow Simulations in Aortic Arch: Effects of Blood Pressure and the Geometry of Arch on Wall Shear Stress
    Vasava, P.
    Jalali, P.
    Dabagh, M.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1926 - 1929
  • [40] Diagnosing congenital heart defects using the Fallot computational model
    Reed, NE
    Gini, M
    Johnson, PE
    Moller, JH
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 1997, 10 (01) : 25 - 40