A sample-to-answer, wearable cloth-based electrochemical sensor (WCECS) for point-of-care detection of glucose in sweat

被引:64
|
作者
Zheng, Lin [1 ,2 ,3 ]
Liu, Yuan [1 ,2 ,3 ]
Zhang, Chunsun [1 ,2 ,3 ]
机构
[1] South China Normal Univ, Coll Biophoton, MOE Key Lab Laser Life Sci, Guangzhou 510631, Peoples R China
[2] South China Normal Univ, Coll Biophoton, Inst Laser Life Sci, Guangzhou 510631, Peoples R China
[3] South China Normal Univ, Coll Biophoton, Guangdong Prov Key Lab Laser Life Sci, Guangzhou 510631, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2021年 / 343卷 / 343期
基金
中国国家自然科学基金;
关键词
Wearable; Cloth-based sensor; Electrochemical; Point-of-care testing; Glucose detection; Sweat; TYPE-2; DIABETES-MELLITUS; BIOSENSOR; METAANALYSIS; SALIVA;
D O I
10.1016/j.snb.2021.130131
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Wearable electrochemical (EC) biosensors have attracted tremendous attention for noninvasive diagnosis and point-of-care testing (POCT) of individual health level. The analysis of glucose concentration in epidermal sweat presents a promising means of noninvasive continuous glucose monitoring for diabetes mellitus. The previous focus has been mainly on pursuing novel EC sensing materials to achieve highly sensitive biosensors. In this work, a novel flexible three-dimensional (3-D) wearable cloth-based EC sensor (WCECS) has been proposed for analysis of glucose in sweat. The WCECS possesses excellent sweat collection channels and cloth-based sweat transport channel. Notably, the transport channel is actuated by the capillary force to absorb the sweat into the cloth-based chip which can be easily and inexpensively fabricated by the screen-printing technology. Under optimized conditions, the WCECS can well measure the concentrations of glucose in sweat over the range of 0.05-1 mM, with an acceptable sensitivity of 105.93 mu A mM-1 cm-2. Besides, the WCECS exhibits excellent selectivity, reproducibility and stability. Importantly, the EC responses of the WCECS have a good correlation with those of the glucometer, and are consistent with the results by the glucose kit. Moreover, the WCECS can be applied for constant 9 h wearable monitoring, and for simultaneous detection of lactic acid and glucose in sweat. So, the proposed approach may represent an important step toward the promising application of the cloth-based sensor for daily personalized health monitoring.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Metal Organic Frameworks Based Wearable and Point-of-Care Electrochemical Sensors for Healthcare Monitoring
    Theyagarajan, K.
    Kim, Young-Joon
    BIOSENSORS-BASEL, 2024, 14 (10):
  • [32] Origami-based "Book" shaped three-dimensional electrochemical paper microdevice for sample-to-answer detection of pathogens
    He, Tao
    Li, Jingwen
    Liu, Lisheng
    Ge, Shenguang
    Yan, Mei
    Liu, Haiyun
    Yu, Jinghua
    RSC ADVANCES, 2020, 10 (43) : 25808 - 25816
  • [33] Point-of-Care, Cable-Type Electrochemical Zn2+ Sensor with Ultrahigh Sensitivity and Wide Detection Range for Soil and Sweat Analysis
    Mondal, Sudeshna
    Subramaniam, Chandramouli
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2019, 7 (17) : 14569 - 14579
  • [34] Challenges and Strategies in Developing an Enzymatic Wearable Sweat Glucose Biosensor as a Practical Point-Of-Care Monitoring Tool for Type II Diabetes
    Khor, Sook Mei
    Choi, Joonhwa
    Won, Phillip
    Ko, Seung Hwan
    NANOMATERIALS, 2022, 12 (02)
  • [35] Sweat-Based in Vitro Diagnostics (IVD): From Sample Collection to Point-of-Care Testing (POCT)
    Mehenur Sarwar
    Pablo Rodriguez
    Chen-zhong Li
    Journal of Analysis and Testing, 2019, 3 : 80 - 88
  • [36] Sweat-Based in Vitro Diagnostics (IVD): From Sample Collection to Point-of-Care Testing (POCT)
    Sarwar, Mehenur
    Rodriguez, Pablo
    Li, Chen-zhong
    JOURNAL OF ANALYSIS AND TESTING, 2019, 3 (01) : 80 - 88
  • [37] Tablet-Based Sensor: A Stable and User-Friendly Tool for Point-of-Care Detection of Glucose in Urine
    Hajimiri, Hasti
    Tali, Seyed Hamid Safiabadi
    Al-Kassawneh, Muna
    Sadiq, Zubi
    Jahanshahi-Anbuhi, Sana
    BIOSENSORS-BASEL, 2023, 13 (09):
  • [38] Feasibility of a 30-Minute Sample-to-Answer Chlamydia Trachomatis, Neisseria Gonorrhea, and Trichomonas Vaginalis Multiplex Test on a Rapid Molecular Point-of-Care System*
    Nguyen, B.
    Pryce, M.
    Parker, E.
    Liang, J.
    Wei, C.
    Crowley, C.
    Green, A.
    Wu, B.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2024, 230 (02) : S649 - S650
  • [39] Electrochemical stripping detection of cadmium with paper-based channels for point-of-care detection
    Han, Ji-Hoon
    Kim, Jinkyeong
    Jin, Joon-Hyung
    Kim, Joon Hyub
    MICROCHEMICAL JOURNAL, 2022, 183
  • [40] Multiple semi-quantitative colorimetric assays in compact embeddable microfluidic cloth-based analytical device (μCAD) for effective point-of-care diagnostic
    Azadeh Nilghaz
    Saeedeh Bagherbaigi
    Chee Leong Lam
    Sayed Mahdi Mousavi
    Emma P. Cόrcoles
    Dedy H. B. Wicaksono
    Microfluidics and Nanofluidics, 2015, 19 : 317 - 333