Look-up table for wall temperature of vertically-upward round tube with heat transfer to supercritical water

被引:5
|
作者
Chang, Fucheng [1 ]
Chan, Wen [1 ]
Wang, Lele [1 ]
Shang, Yuhao [1 ]
Feng, Yuan [1 ]
Li, Huixiong [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
关键词
Supercritical water (SCW); Wall temperature; Look-up table (LUT); Four-dimensional linear interpolation; Heat transfer database; PRESSURE WATER; SMOOTH; PREDICTION; EFFICIENCY; FLUIDS; STEAM;
D O I
10.1016/j.applthermaleng.2021.117440
中图分类号
O414.1 [热力学];
学科分类号
摘要
Wall temperature of heat transfer tubes is one of the most important parameters indicating the operation safety of various heat transfer facilities, and as a result, estimation of the wall temperature becomes one of the main tasks in the design of heat transfer facilities. The wall temperature look-up table (Tw-LUT) can be established directly from experimental data and can be then used to estimate the wall temperature of the heat transfer tubes, avoiding the approximation or extrapolation of fluid properties that inevitably exists in the heat transfer correlations. In view of the problems existing in applications with wall temperature estimations of the heat transfer tube, such as limited data points and the limited application scopes of parameters, a look-up table is built in this paper for wall temperatures of vertically-upward round tubes of 10 mm tube diameter with heat transfer to supercritical water (SCW), under conditions with pressure in the range from 22.5 to 31 MPa, the mass velocity in the range from 200 to 3000 kg.m(-2).s(-1), the heat flux in the range from 200 to 1800 kW.m(-2), and the bulk fluid enthalpy in the range from 1000 to 3000 kJ.kg(-1). In order to cover the gaps between the experimental data points, and to improve the prediction accuracy of the Tw-LUT, the best heat transfer correlation is selected for each local area of interest in the LUT based on its prediction accuracy in the corresponding local area, and then the best heat transfer correlation is adopted to supplement wall temperature results to fill up the Tw-LUT. The comparison between the wall temperatures by the Tw-LUT and the experimental wall temperatures is carried out to verify the accuracy of the Tw-LUT, and it is shown that the mean absolute deviation of the results is 0.87%, and 87.81% of the results fall into the +/- 3% error band, indicating that the Tw-LUT has a good accuracy for wall temperature prediction and the establishment method is reliable and can be used to build other look-up tables. The Tw-LUT can be applied not only to normal heat transfer conditions but also to deteriorated heat transfer conditions and enhanced heat transfer conditions with a satisfactory accuracy.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Forced Convection Heat Transfer Using High Temperature and Pressure Water in an Upward-Inclined Tube
    Gang, Wu
    Bi, Qincheng
    Wang, Han
    Yang, Zhendong
    Zhu, Xiaojing
    Hu, Zhihong
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2012, 134 (02):
  • [42] Forced convection heat transfer using high temperature and pressure water in an upward-inclined tube
    State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an, Shanxi, 710049, China
    J. Heat Transf., 2
  • [43] Heat transfer and frictional resistance characteristics of the water wall tube of an ultra-supercritical CFB boiler
    Wang, Wenyu
    Yang, Dong
    Jiang, Huiqing
    Qu, Mofeng
    Zhao, Yunjie
    JOURNAL OF SUPERCRITICAL FLUIDS, 2017, 128 : 279 - 290
  • [44] NUMERICAL INVESTIGATION ON HEAT TRANSFER TO SUPERCRITICAL WATER FLOWING UPWARD IN A 4-M LONG BARE VERTICAL CIRCULAR TUBE
    Yang, Dong
    Wu, Qixian
    Chen, Lin
    Pioro, Igor
    PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE2020), VOL 3, 2020,
  • [45] The Effect of Buoyancy on Heat Transfer in Supercritical Water Flow in a Horizontal Round Tube (vol 127, pg 897, 2005)
    Bazargan, Majid
    Fraser, Daniel
    Chatoorgan, Vijay
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2011, 133 (06):
  • [46] EXPERIMENTAL INVESTIGATION ON HEAT TRANSFER CHARACTERISTICS OF SMOOTH WATER WALL TUBE OF AN ULTRA-SUPERCRITICAL CFB BOILER
    Wang, Wenyu
    Liang, Ziyu
    Wan, Li
    Liu, Dan
    Yang, Dong
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 8A, 2019,
  • [47] Heat transfer characteristics of supercritical water in a horizontal tube considering local temperature fields: An experimental study
    Huang, Xin
    Qin, Jiaxi
    Hou, Zhenghui
    Gao, Yu
    Zhang, Shengjie
    Wang, Haijun
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 198
  • [48] Heat Transfer to Sub- and Supercritical Water Flowing Upward in a Vertical Tube at Low Mass Fluxes: Numerical Analysis and Experimental Validation
    Odu, Samuel O.
    Koster, Pelle
    van der Ham, Aloijsius G. J.
    van der Hoef, Martin A.
    Kersten, Sascha R. A.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (51) : 13120 - 13131
  • [49] Influences of heat transfer crisis on temperature profile of supercritical water wall in near critical pressure region
    School of Energy and Power Engineering, North China Electric Power University, Baoding 071003, Hebei Province, China
    Zhongguo Dianji Gongcheng Xuebao, 2009, 35 (48-53):
  • [50] Experimental and numerical investigation on heat transfer in the vertical upward flow water wall of a 660 MW ultra-supercritical CFB boiler
    Zhou, Xihong
    Niu, Tiantian
    Xin, Yafei
    Li, Yinlong
    Yang, Dong
    APPLIED THERMAL ENGINEERING, 2021, 188