Determination of minimum alveolar concentration of isoflurane in dogs and cats using the up-and-down method. A preliminary study

被引:12
|
作者
Barletta, Michele [1 ]
Quandt, Jane [2 ]
Hofmeister, Erik [2 ]
机构
[1] Univ Georgia, Coll Vet Med, Dept Large Anim Med, 2200 Coll Stn Rd, Athens, GA 30602 USA
[2] Univ Georgia, Dept Small Anim Med & Surg, Coll Vet Med, Athens, GA 30602 USA
关键词
Bracketing technique; Cat; Dog; MAC determination; Up-and-down method; TIDAL SEVOFLURANE CONCENTRATION; TRACHEAL EXTUBATION; ANESTHETIC CONCENTRATION; HALOTHANE; REDUCTION; METHOXYFLURANE; EMERGENCE; KETAMINE; CHILDREN; ETHER;
D O I
10.1016/j.rvsc.2016.03.011
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Minimum alveolar concentration (MAC) is a reliable measurement of the potency of inhaled anesthetic agents. The determination of MAC in different species has followed a fairly consistent methodology. In people, MAC is determined with the up-and-down method, whereas in animal the bracketing technique is commonly used. The objectives of this study were to determine the MAC value of isoflurane in dogs and cats using the up-and-down method and to determine the MAC value of isoflurane at extubation (MAC(ex)). General anesthesia was induced in 13 dogs and 5 cats with 5% isoflurane in oxygen. An initial end-tidal isoflurane concentration of 1.3% was used for the first dog and of 1.6% for the first cat and maintained constant for >= 20 min. A noxious stimulus in the form of Carmalt forceps was applied to the base of the tail for no more than one minute or until movement was noticed. After stimulation, the response was recorded as positive (movement) or negative (no movement) and the animal was recovered. The end-tidal isoflurane concentration of the following animal was increased or decreased by 0.1% if the response of the previous animal to the stimulus was negative or positive, respectively. Isoflurane MAC values in dogs were 1.27% and 1.23%. Isoflurane MAC value in cats was 1.58%. MAC, value was 0.45% in dogs and in cats. The up-and-down method for MAC determination achieved similar results when compared to MAC values of isoflurane in dogs and cats reported in the literature using the bracketing technique. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:81 / 83
页数:3
相关论文
共 23 条
  • [21] ED50 and ED95 of Propofol Combined with Different Doses of Intravenous Lidocaine for First-Trimester Uterine Aspiration: A Prospective Dose-Finding Study Using Up-and-Down Sequential Allocation Method
    Zhang, Jingwen
    Kong, Linglingli
    Ni, Juan
    DRUG DESIGN DEVELOPMENT AND THERAPY, 2022, 16 : 3343 - 3352
  • [22] To Determine the Minimum Effective Volume of Local Anesthetic in 50% Patients(MEAV50)Using Dixon's Up and Down Method for Ultrasound Guided Supraclavicular Brachial Plexus Block: One Year Hospital Based Clinical Study
    Suresh, Honneshwari
    Mane, Rajesh
    Killedar, Neha P.
    ANESTHESIA AND ANALGESIA, 2024, 139 (06): : 2493 - 2494
  • [23] Remimazolam dose for successful insertion of a supraglottic airway device with opioids: a dose-determination study using Dixon’s up-and-down method; [Dose de remimazolam pour réussir l’insertion d’un dispositif supraglottique avec des opioïdes : une étude de détermination de la dose utilisant la méthode de l’escalier de Dixon]
    Kim J.
    Lee S.
    Kim Y.
    Jeong J.S.
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2023, 70 (3): : 343 - 350