Novel Method for Measuring the Grounding Resistance of Towers With Short Electrode Wire

被引:2
|
作者
Zhang, Zhanlong [1 ]
Dong, Zijian [1 ]
Dan, Yihua [1 ]
Li, Yiqiao [1 ]
Jiang, Peiyu [1 ]
Liu, Guohua [2 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmission Equipment & Syst, Chongqing 400030, Peoples R China
[2] Quzhou Power Supply Co, State Grid Zhejiang Elect Power Co Ltd, Quzhou 324000, Peoples R China
基金
中国国家自然科学基金;
关键词
Arranging electrodes inside the tower foundation; connectivity of the soil; short electrode wire; tower grounding resistance measurement;
D O I
10.1109/TIM.2021.3070865
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The three-electrode method is the most commonly used grounding resistance measurement method. But the electrode wire of the three-electrode method is too long to be used in mountainous areas or densely built areas. Therefore, it is of great application value to effectively shorten the electrode wire under the condition of ensuring measurement accuracy. In this article, a novel method for measuring the grounding resistance of towers with short electrode wire is proposed. Based on the connectivity of soil inside and outside the tower foundation, the limited space inside the tower foundation is fully used to arrange the electrodes. The principle of arranging electrodes inside the tower foundation to measure the grounding resistance is deduced in detail. The calculation method of the compensation point position and measurement error is studied. The best way of arranging electrodes is proposed. Through simulation experiments and field tests, we confirmed that the measurement accuracy of this novel method is similar to that of the three-electrode method. Its electrode wire length is shorter than the three-electrode method and other improved methods. Only the length of electrode wire needs to be the same as the length of the grounding conductor, and the measurement error can be controlled at about 3%. The novel grounding resistance measurement method has a wider application range and higher measurement efficiency.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A TECHNIQUE OF MEASURING OF RESISTANCE OF A GROUNDING DEVICE
    Nizhevskyi, I. V.
    Nizhevskyi, V. I.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2016, (03) : 50 - 57
  • [22] A Novel Grounding Electrode Line Protection Method Based on Harmonic Impedance
    Zhang, Yuelang
    Li, Xiaopeng
    Teng, Yufei
    Lu, Jiping
    Zhuang, Yi
    2022 4TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2022), 2022, : 27 - 32
  • [23] Simulation of Impact of Vertical Grounding Electrode on Impulse Grounding Resistance of Substation Grounding Network
    Zhou, Lijun
    He, Jian
    Xu, Han
    Wang, Pengcheng
    Chen, Ying
    Chen, Sixiang
    2017 2ND IEEE INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUITS AND MICROSYSTEMS (ICICM), 2017, : 18 - 22
  • [24] Wire resistance method for measuring the corrosion of copper by lubricating fluids
    Hunt, Gregory J.
    Gahagan, Michael P.
    Peplow, Mitchell A.
    LUBRICATION SCIENCE, 2017, 29 (04) : 279 - 290
  • [25] The measurement of grounding resistance based on third-order cumulant measuring method
    Li, MT
    ICSP '96 - 1996 3RD INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, PROCEEDINGS, VOLS I AND II, 1996, : 572 - 575
  • [26] Experimental investigation of transient grounding resistance characteristics on a spokewise grounding electrode
    Chen Jiaqing
    Zhou Bihua
    He Hongbing
    Meng Xin
    Huang Xiaofang
    2007 4TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY PROCEEDING: EMC 2007, 2007, : 350 - +
  • [27] Research on Fast Measurement Method of GIS Circuit Resistance without Removing Grounding Wire
    Lai Junju
    Peng Hao
    Jiang Yunpeng
    Hu Jinlei
    Huang Shihua
    Wang Wenbo
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3547 - 3552
  • [28] Experimental investigation of transient grounding resistance characteristics on spokewise grounding electrode
    Chen, Jia-Qing
    Zhou, Bi-Hua
    Zhao, Fei
    Guo, Fei
    Huang, Xiao-Fang
    Jiefangjun Ligong Daxue Xuebao/Journal of PLA University of Science and Technology (Natural Science Edition), 2010, 11 (02): : 142 - 146
  • [29] Experimental investigation of transient grounding resistance characteristics on the radialized grounding electrode
    Chen Jiaqing
    Zhou Bihua
    Zhao Fei
    Guo Fei
    Huang Xiaofang
    2008 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS, VOLS 1-4, 2008, : 1458 - +
  • [30] STEP POTENTIALS NEAR A BURIED-WIRE GROUNDING ELECTRODE
    ROBERTSON, NC
    VALENTINO, AR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (01): : 3 - 3