Diagnostic value of fine-needle aspiration biopsy for breast mass: a systematic review and meta-analysis

被引:43
|
作者
Yu, Ying-Hua
Wei, Wei
Liu, Jian-Lun [1 ]
机构
[1] Guangxi Med Univ, Guangxi Canc Hosp, Dept Breast Surg, Nanning 530021, Guangxi, Peoples R China
关键词
MAMMOGRAPHIC ABNORMALITIES; TRIPLE ASSESSMENT; CORE BIOPSY; ODDS RATIO; CYTOLOGY; CANCER; MANAGEMENT; LESIONS; LOCALIZATION; ACCURACY;
D O I
10.1186/1471-2407-12-41
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Fine-needle aspiration biopsy (FNAB) of the breast is a minimally invasive yet maximally diagnostic method. However, the clinical use of FNAB has been questioned. The purpose of our study was to establish the overall value of FNAC in the diagnosis of breast lesions. Methods: After a review and quality assessment of 46 studies, sensitivity, specificity and other measures of accuracy of FNAB for evaluating breast lesions were pooled using random-effects models. Summary receiver operating characteristic curves were used to summarize overall accuracy. The sensitivity and specificity for the studies data (included unsatisfactory samples) and underestimation rate of unsatisfactory samples were also calculated. Results: The summary estimates for FNAB in diagnosis of breast carcinoma were as follows (unsatisfactory samples was temporarily exluded): sensitivity, 0.927 (95% confidence interval [CI], 0.921 to 0.933); specificity, 0.948 (95% CI, 0.943 to 0.952); positive likelihood ratio, 25.72 (95% CI, 17.35 to 28.13); negative likelihood ratio, 0.08 (95% CI, 0.06 to 0.11); diagnostic odds ratio, 429.73 (95% CI, 241.75 to 763.87); The pooled sensitivity and specificity for 11 studies, which reported unsatisfactory samples (unsatisfactory samples was considered to be positive in this classification) were 0.920 (95% CI, 0.906 to 0.933) and 0.768 (95% CI, 0.751 to 0.784) respectively. The pooled proportion of unsatisfactory samples that were subsequently upgraded to various grade cancers was 27.5% (95% CI, 0.221 to 0.296). Conclusions: FNAB is an accurate biopsy for evaluating breast malignancy if rigorous criteria are used. With regard to unsatisfactory samples, futher invasive procedures are required in order to minimize the chance of a missed diagnosis of breast cancer.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Diagnostic value of core needle biopsy and fine-needle aspiration in salivary gland lesions
    Novoa, Eva
    Guertler, Nicolas
    Arnoux, Andre
    Kraft, Marcel
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2016, 38 : E346 - E352
  • [32] Diagnostic accuracy of ultrasound-guided fine needle aspiration biopsy for thyroid malignancy: systematic review and meta-analysis
    Ospina, Naykky Singh
    Brito, Juan P.
    Maraka, Spyridoula
    de Ycaza, Ana E. Espinosa
    Rodriguez-Gutierrez, Rene
    Gionfriddo, Michael R.
    Castaneda-Guarderas, Ana
    Benkhadra, Khalid
    Al Nofal, Alaa
    Erwin, Patricia
    Morris, John C.
    Castro, M. Regina
    Montori, Victor M.
    ENDOCRINE, 2016, 53 (03) : 651 - 661
  • [33] Diagnostic accuracy of ultrasound-guided fine needle aspiration biopsy for thyroid malignancy: systematic review and meta-analysis
    Naykky Singh Ospina
    Juan P. Brito
    Spyridoula Maraka
    Ana E. Espinosa de Ycaza
    Rene Rodriguez-Gutierrez
    Michael R. Gionfriddo
    Ana Castaneda-Guarderas
    Khalid Benkhadra
    Alaa Al Nofal
    Patricia Erwin
    John C. Morris
    M. Regina Castro
    Victor M. Montori
    Endocrine, 2016, 53 : 651 - 661
  • [34] Sensitivity, Specificity, and Posttest Probability of Parotid Fine-Needle Aspiration: A Systematic Review and Meta-analysis
    Liu, C. Carrie
    Jethwa, Ashok R.
    Khariwala, Samir S.
    Johnson, Jonas
    Shin, Jennifer J.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 154 (01) : 9 - 23
  • [35] Diagnostic value of telomerase expression in breast fine-needle aspiration biopsies
    Fischer, Gabor
    Tutuncuoglu, Osman
    Bakhshandeh, Maryam
    Masood, Shahla
    DIAGNOSTIC CYTOPATHOLOGY, 2007, 35 (10) : 653 - 655
  • [36] The accuracy of ultrasound-guided fine-needle aspiration and core needle biopsy in diagnosing axillary lymph nodes in women with breast cancer: a systematic review and meta-analysis
    Zheng, Haining
    Zhao, Rui
    Wang, Wei
    Liu, Xiaona
    Wang, Xiaoqing
    Wen, Chaoyang
    Ren, Yubo
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [37] Is 19 G Core Biopsy Needle Superior to 22 G Fine-Needle Aspiration in Diagnosis of Autoimmune Pancreatitis? a Meta-Analysis and Systematic Review
    Sofi, Aijaz A.
    Hammad, Tariq A.
    Khan, Muhammad Ali
    Alastal, Yaseen
    Nawras, Ali
    GASTROINTESTINAL ENDOSCOPY, 2017, 85 (05) : AB355 - AB355
  • [38] Diagnostic Value of Fine-Needle Aspiration Biopsy in Major Salivary Gland Masses
    Gulustan, Filiz
    Abakay, Mehmet Akif
    Atasoy, Ercan
    Yazici, Zahide Mine
    Sayin, Ibrahim
    MEDICAL JOURNAL OF BAKIRKOY, 2021, 17 (03) : 184 - 189
  • [39] Diagnostic Accuracy of Fine-Needle Aspiration Cytology and Core-Needle Biopsy in the Assessment of the Axillary Lymph Nodes in Breast Cancer-A Meta-Analysis
    Pyo, Jung-Soo
    Jung, Jaehag
    Lee, Seul Gi
    Kim, Nae-Yu
    Kang, Dong-Wook
    DIAGNOSTICS, 2020, 10 (09)
  • [40] DIAGNOSTIC-VALUE OF FINE-NEEDLE ASPIRATION BIOPSY UNDER ULTRASONOGRAPHY - REPLY
    COCHANDPRIOLLET, B
    GUILLAUSSEAU, PJ
    CHAGNON, S
    HOANG, C
    GUILLAUSSEAUSCHOLER, C
    CHANSON, P
    DAHAN, H
    WARNET, A
    HUY, PTB
    VALLEUR, P