Environmental noise pollution control of substation by passive vibration and acoustic reduction strategies

被引:19
|
作者
Fan, Xiaopeng [1 ]
Li, Li [1 ]
Zhao, Li [1 ]
He, Hongming [3 ]
Zhang, Dianhai [2 ]
Ren, Ziyan [2 ]
Zhang, Yanli [2 ]
机构
[1] Guangdong Power Grid Ltd Liabil Corp, Electri Power Res Inst, Guangzhou 510082, Peoples R China
[2] Shengyang Univ Technol, Sch Elect Engn, Shenyang 110870, Peoples R China
[3] Guangdong Power Grid Ltd Liabil Corp, Dongguan Power Supply Bur, Dongguan 52300, Peoples R China
关键词
Acoustic insulation; Distribution transformer; Noise reduction and vibration control; Sound absorbing; Vibration isolation; POWER TRANSFORMER; ACTIVE CONTROL;
D O I
10.1016/j.apacoust.2020.107305
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Recently, residents in a specific urban area in China has complained against the noise pollution from a particular indoor substation. This paper aims at solving this problem through experimental investigations on the vibration and noise created by distribution transformers in the substation. Firstly, the noise around the distribution transformers, substation, and in the noise-sensitive room were measured. Secondly, through frequency characteristic analysis, the center frequencies at 250 Hz and 500 Hz with maximum values can be obtained and defined as main frequencies in this paper. Once the frequency of the main noises generated by the distribution transformers are identified, the sound absorbing structure, acoustic insulation structure, and vibration isolators were designed and installed. Following the treatment of noise pollution, the transformer and environment noise were reevaluated. The measurement results show that the integrated strategies proposed lead to effectively inhibiting the distribution transformer noise emitted into the surrounding environment. Consequently, the acoustic environment around the indoor substation was drastically improved. For this case study, the residential bedroom located above the substation is considered as a noise-sensitive room. The measurement following the treatment of noise shows that the average equivalent sound pressure level (SPL) in this room was successfully reduced approximately 6 dB at daytime and 10 dB at night, respectively. The corresponding measurement results illustrate that the SPL satisfied the requirement of limits of the ordinance. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] A case study of noise pollution and its control in an Eco-friendly 500 kV substation
    Li, Hualiang
    Li, Li
    Zhang, Kai
    Chen, Min
    Fan, Xiaopeng
    Liu, Yuzhong
    Wu, Peiqi
    Shen, Yali
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3336 - 3340
  • [42] Vibration and Acoustic Noise Reduction in Switched Reluctance Motor by Selective Radial Force Harmonics Reduction
    Wiguna, Candra Adi
    Cai, Yifei
    Lilian, Lim Li Sing Sarah
    Furqani, Jihad
    Fujii, Yusuke
    Kiyota, Kyohei
    Chiba, Akira
    IEEE OPEN JOURNAL OF INDUSTRY APPLICATIONS, 2023, 4 : 23 - 34
  • [43] Passive acoustic liners for aero-engine noise control: A review
    Ma, Pengwei
    Wang, Han
    Li, Danwang
    Yuan, Shanhu
    Fan, Xueling
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2024, 31 (30) : 12834 - 12849
  • [44] NOISE POLLUTION-CONTROL - STEPCHILD OF ENVIRONMENTAL-PROTECTION
    不详
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1973, 25 (25): : 705 - 705
  • [45] Noise reduction control strategies for switched reluctance drives
    Kasper, Knut A.
    Fiedler, Jens O.
    Schmitz, Daniel
    De Doncker, Rik W.
    2006 IEEE VEHICLE POWER AND PROPULSION CONFERENCE, 2006, : 22 - +
  • [46] Mobility and Noise Pollution. Noise-Reduction Traditional Strategies and Green Mobility Ones
    Gargiulo, Carmela
    Romano, Rosario
    TEMA-JOURNAL OF LAND USE MOBILITY AND ENVIRONMENT, 2011, 4 (02) : 43 - 54
  • [47] Acoustic resonator tuning strategies for the narrowband noise control in an enclosure
    Hu, Zhongyu
    Yang, Cheng
    Cheng, Li
    APPLIED ACOUSTICS, 2018, 134 : 88 - 96
  • [48] Smooth Voltage PWM for Vibration and Acoustic Noise Reduction in Switched Reluctance Machines
    Pupadubsin, Ruchao
    Mecrow, Barrie C.
    Widmer, James D.
    Steven, Andrew
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2021, 36 (03) : 1578 - 1588
  • [49] Interlaminated damping - A method for reduction of vibration and acoustic noise for switched reluctance machines
    Rasmussen, PO
    LaBrush, EC
    Andreasen, JH
    Conference Record of the 2005 IEEE Industry Applications Conference, Vols 1-4, 2005, : 1531 - 1539
  • [50] Environmental noise and vibration control of the Rose Theatre, Brampton, Ontario
    Swallow, John C.
    Toome, Mihkel
    Yung, Pearlie
    Canadian Acoustics - Acoustique Canadienne, 2010, 38 (01): : 3 - 6