Low-cost computer-controlled current stimulator for the student laboratory

被引:4
|
作者
Gueclue, Burak [1 ]
机构
[1] Bogazici Univ, Inst Biomed Engn, TR-34342 Istanbul, Turkey
关键词
voltage-to-current converter; audio output; neurophysiology; frog; sciatic nerve;
D O I
10.1152/advan.00110.2006
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Low-cost computer-controlled current stimulator for the student laboratory. Adv Physiol Educ 31: 223-231, 2007; doi:10.1152/advan.00110.2006.- Electrical stimulation of nerve and muscle tissues is frequently used for teaching core concepts in physiology. It is usually expensive to provide every student group in the laboratory with an individual stimulator. This article presents the design and application of a low-cost [ about $ 100 ( U. S.)] isolated stimulator that can be controlled by two analog-output channels ( e. g., output channels of a data-acquisition card or onboard audio channels) of a computer. The device is based on a voltage-to-current converter circuit and can produce accurate monopolar and bipolar current pulses, pulse trains, arbitrary current waveforms, and a trigger output. The compliance of the current source is +/- 15 V, and the maximum available current is +/- 1.5 mA. The device was electrically tested by using the audio output of a personal computer. In this condition, the device had a dynamic range of 46 dB and the available pulse-width range was 0.1 - 10 ms. The device is easily programmable, and a freeware MATLAB script is posted on the World Wide Web. The practical use of the device was demonstrated by electrically stimulating the sciatic nerve of a frog and recording compound action potentials. The newly designed current stimulator is a flexible and effective tool for teaching in the physiology laboratory, and it can increase the efficiency of learning by maximizing performance-to-cost ratio.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 50 条
  • [41] Low-noise computer-controlled current source for quantum coherence experiments
    Linzen, S
    Robertson, TL
    Hime, T
    Plourde, BLT
    Reichardt, PA
    Clarke, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (08): : 2541 - 2544
  • [42] A COMPUTER-CONTROLLED LABORATORY FOR STUDYING INFANT EVENT PERCEPTION
    KRAMER, SJ
    BERTENTHAL, BI
    BAI, DL
    BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1986, 18 (02): : 257 - 262
  • [43] THE LOW-COST TRIBOLOGY LABORATORY
    SCHOFIELD, J
    WEAR, 1981, 66 (01) : 1 - 7
  • [44] LOW-COST GRAPHICS FOR THE LABORATORY
    DEININGER, RA
    GRAY, RH
    JOURNAL OF CLINICAL LABORATORY AUTOMATION, 1984, 4 (05): : 321 - 326
  • [45] Low-cost Laboratory Materials
    Deimler, Lillie L.
    AMERICAN JOURNAL OF NURSING, 1941, 41 (09) : 1036 - 1038
  • [46] LOW-COST LABORATORY CART
    MCINTOSH, TH
    MAYLAND, HF
    CHEMIST-ANALYST, 1964, 53 (03) : 95 - &
  • [47] DESIGN OF A COMPUTER-CONTROLLED LABORATORY IN ANALYTICAL-CHEMISTRY
    EBEL, S
    HOCKE, J
    REYER, B
    WALTER, V
    WEIDEMANN, E
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 311 (04): : 441 - 442
  • [48] A COMPUTER-CONTROLLED LABORATORY QUALITY-CONTROL SYSTEM
    BUCHER, D
    CHRISTIANSEN, JU
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1986, 46 : 190 - 190
  • [49] Microrobot laboratory and computer-controlled workstation - a new paradigm for the clinical laboratory
    Scherbaum, WA
    MEDIZINISCHE KLINIK, 1998, 93 (12) : 738 - 738
  • [50] LOW-COST COMPUTER TERMINALS
    不详
    ELECTRONIC PRODUCTS MAGAZINE, 1980, 22 (09): : 63 - 64