Percutaneous Transvenous Melody Valve-in-Ring Procedure for Mitral Valve Replacement

被引:29
|
作者
Shuto, Takashi [2 ,3 ]
Kondo, Norihiro [2 ,3 ]
Dori, Yoav [1 ]
Koomalsingh, Kevin J. [2 ,3 ]
Glatz, Andrew C. [1 ]
Rome, Jonathan J. [1 ]
Gorman, Joseph H., III [2 ,3 ]
Gorman, Robert C. [2 ,3 ]
Gillespie, Matthew J. [1 ,2 ]
机构
[1] Univ Penn, Sch Med, Childrens Hosp Philadelphia, Dept Pediat,Div Cardiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Gorman Cardiovasc Res Grp, Philadelphia, PA 19104 USA
[3] Univ Penn, Sch Med, Dept Surg, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
annuloplasty ring; Melody valve; mitral valve; mitral valve insufficiency; mitral valve repair; mitral valve replacement; percutaneous valve replacement; REPAIR; IMPLANTATION; REGURGITATION; PROSTHESIS; STENOSIS;
D O I
10.1016/j.jacc.2011.09.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The purpose of this study was to demonstrate the feasibility of percutaneous transvenous mitral valve-in-ring (VIR) implantation using the Melody valve in an ovine model. Background The recurrence of mitral regurgitation following surgical mitral valve (MV) repair in both adult and pediatric patients remains a significant clinical problem. Mitral annuloplasty rings are commonly used in MV repair procedures and may serve as secure landing zones for percutaneous valves. Methods Five sheep underwent surgical MV annuloplasty (24 mm, n = 2; 26 mm, n = 2; 28 mm, n = 1). Animals underwent cardiac catheterization with VIR implantation via a transfemoral venous, transatrial septal approach 1 week following surgery. Hemodynamic, angiographic, and echocardiographic data were recorded before and after VIR. Results VIR was technically successful and required <1 h of procedure time in all animals. Fluoroscopy demonstrated securely positioned Melody valves within the annuloplasty ring in all animals. Angiography revealed no significant MV regurgitation in 4 and moderate central MV regurgitation in the animal with the 28-mm annuloplasty. All animals demonstrated vigorous left ventricular function, no outflow tract obstruction, and no aortic valve insufficiency. Conclusions This study demonstrated the feasibility of a purely percutaneous approach to MV replacement in patients with preexisting annuloplasty rings. This novel approach may be of particular benefit to patients with failed repair of ischemic mitral regurgitation and in pediatric patients with complex structural heart disease. (J Am Coll Cardiol 2011;58:2475-80) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:2475 / 2480
页数:6
相关论文
共 50 条
  • [31] Prosthetic ring dehiscence during mitral valve-in-ring
    Sabatel-Perez, Fernando
    Carrasco-Chinchilla, Fernando
    Alonso-Briales, Juan H.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2021, 74 (12): : 1107 - 1108
  • [32] Mitral valve-in-valve and valve-in-ring: technical aspects and procedural outcomes
    Dvir, Danny
    Webb, John
    EUROINTERVENTION, 2016, 12 : Y93 - Y96
  • [33] Numerical simulation of transcatheter mitral valve replacement: The dynamic implication of LVOT obstruction in the valve-in-ring case
    Pasta, Salvatore
    Catalano, Chiara
    Cannata, Stefano
    Guccione, Julius M.
    Gandolfo, Caterina
    JOURNAL OF BIOMECHANICS, 2022, 144
  • [34] Percutaneous Mitral Valve-in-Ring Procedure in a Case of Severe Mitral Regurgitation Repaired with a Surgical Flexible Ring: A Step-by-Step Description
    Bozbas, Huseyin
    Celebi, Savas Aksuyek
    Asfour, Mohamed
    Amasyali, Basri
    Barcin, Cem
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2025, 53 (01): : 68 - 72
  • [35] Numerical simulation of transcatheter mitral valve replacement: The dynamic implication of LVOT obstruction in the valve-in-ring case
    Pasta, Salvatore
    Catalano, Chiara
    Cannata, Stefano
    Guccione, Julius M.
    Gandolfo, Caterina
    Journal of Biomechanics, 2022, 144
  • [36] Transvenous Mitral Valve Replacement After Failure of Surgical Ring Annuloplasty
    Himbert, Dominique
    Descoutures, Fleur
    Brochet, Eric
    Iung, Bernard
    Detaint, Delphine
    Messika-Zeitoun, David
    Alkhoder, Soleiman
    Mimoun, Lea
    Sordi, Martina
    Depoix, Jean-Pol
    Ducrocq, Gregory
    Nataf, Patrick
    Vahanian, Alec
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (13) : 1205 - 1206
  • [37] Transcatheter mitral valve-in-ring implantation with the direct flow medical valve
    Latib, A.
    Gatto, F.
    Bijuklic, K.
    Oezbek, C.
    Colombo, A.
    Schofer, J.
    EUROPEAN HEART JOURNAL, 2015, 36 : 445 - 445
  • [38] A meta-analysis of valve-in-valve and valve-in-ring transcatheter mitral valve implantation
    Takagi, Hisato
    Hari, Yosuke
    Kawai, Norikazu
    Ando, Tomo
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2018, 31 (06) : 899 - 906
  • [39] Mitral valve-in-ring: the good, the bad, and the ugly
    Bapat, Vinayak
    EUROINTERVENTION, 2016, 11 (10) : 1092 - 1094
  • [40] Mitral valve-in-valve, valve-in-ring, and valve-in-MAC: the Good, the Bad, and the Ugly
    Maisano, Francesco
    Taramasso, Maurizio
    EUROPEAN HEART JOURNAL, 2019, 40 (05) : 452 - 455