Robust principal component analysis-based four-dimensional computed tomography

被引:157
|
作者
Gao, Hao [1 ]
Cai, Jian-Feng [1 ]
Shen, Zuowei [2 ]
Zhao, Hongkai [3 ]
机构
[1] Univ Calif Los Angeles, Dept Math, Los Angeles, CA 90095 USA
[2] Natl Univ Singapore, Dept Math, Singapore 117543, Singapore
[3] Univ Calif Irvine, Dept Math, Irvine, CA 92697 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 11期
关键词
RADIATION-THERAPY; IMAGE-RESTORATION; DOSE REDUCTION; DATA-FIDELITY; CT; ALGORITHM; RECONSTRUCTION; REGULARIZATION; REGISTRATION; METHODOLOGY;
D O I
10.1088/0031-9155/56/11/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this paper for four-dimensional (4D) computed tomography (CT) is threefold. (1) A new spatiotemporal model is presented from the matrix perspective with the row dimension in space and the column dimension in time, namely the robust PCA (principal component analysis)-based 4D CT model. That is, instead of viewing the 4D object as a temporal collection of three-dimensional (3D) images and looking for local coherence in time or space independently, we perceive it as a mixture of low-rank matrix and sparse matrix to explore the maximum temporal coherence of the spatial structure among phases. Here the low-rank matrix corresponds to the 'background' or reference state, which is stationary over time or similar in structure; the sparse matrix stands for the 'motion' or time-varying component, e. g., heart motion in cardiac imaging, which is often either approximately sparse itself or can be sparsified in the proper basis. Besides 4D CT, this robust PCA-based 4D CT model should be applicable in other imaging problems for motion reduction or/and change detection with the least amount of data, such as multi-energy CT, cardiac MRI, and hyperspectral imaging. (2) A dynamic strategy for data acquisition, i.e. a temporally spiral scheme, is proposed that can potentially maintain similar reconstruction accuracy with far fewer projections of the data. The key point of this dynamic scheme is to reduce the total number of measurements, and hence the radiation dose, by acquiring complementary data in different phases while reducing redundant measurements of the common background structure. (3) An accurate, efficient, yet simple-to-implement algorithm based on the split Bregman method is developed for solving the model problem with sparse representation in tight frames.
引用
收藏
页码:3181 / 3198
页数:18
相关论文
共 50 条
  • [21] Principal component analysis-based mesh decomposition
    Department of Electronic Engineering, National Taiwan University of Science and Technology, Taipei, 106, Taiwan
    不详
    不详
    J. Inf. Sci. Eng., 2009, 4 (971-987):
  • [22] Principal component analysis-based mesh decomposition
    Chang, Jung-Shiong
    Shih, Arthur Chun-Chieh
    Liao, Hong-Yuan Mark
    Fang, Wen-Hsien
    2007 IEEE NINTH WORKSHOP ON MULTIMEDIA SIGNAL PROCESSING, 2007, : 292 - +
  • [23] Performance studies of four-dimensional cone beam computed tomography
    Qi, Zhihua
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20): : 6709 - 6721
  • [24] Parathyroid Imaging Four-dimensional Computed Tomography, Sestamibi, and Ultrasonography
    Strauss, Sara B.
    Roytman, Michelle
    Phillips, C. Douglas
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2021, 31 (03) : 379 - 395
  • [25] Four-dimensional Computed Tomography for Preoperative Localization of Parathyroid Adenomas
    Zeina, Abdel-Rauf
    Nakar, Helit
    Reindorp, Nadir
    Nachtigal, Alicia
    Krausz, Michael M.
    Ashkenazi, Itamar
    Shapira-Rootman, Mika
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2017, 19 (04): : 216 - 220
  • [26] Four-dimensional computed tomography and detection of dynamic capitate subluxation
    Repse, Stephen E.
    Amis, Benjamin
    Troupis, John M.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2015, 59 (03) : 331 - 335
  • [27] Motion artifact detection in four-dimensional computed tomography images
    Bouilhol, G.
    Ayadi, M.
    Pinho, R.
    Rit, S.
    Sarrut, D.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [28] Evaluation of stuck mechanical valve with four-dimensional computed tomography
    Numata, Satoshi
    Tsutsumi, Yasushi
    Ohashi, Hirokazu
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (03) : 594 - 594
  • [29] Dynamic ventilation imaging from four-dimensional computed tomography
    Guerrero, T
    Sanders, K
    Castillo, E
    Zhang, Y
    Bidaut, L
    Pan, TS
    Komaki, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04): : 777 - 791
  • [30] Dynamic Four-Dimensional Computed Tomography Angiography for Neurovascular Pathologies
    Alnemari, Ahmed
    Mansour, Tarek R.
    Bazerbashi, Mohamad
    Buehler, Mark
    Schroeder, Jason
    Gaudin, Daniel
    WORLD NEUROSURGERY, 2017, 105 : 1034.e11 - 1034.e18