Dosimetry comparison between volumetric modulated arc therapy with RapidArc and fixed field dynamic IMRT for local-regionally advanced nasopharyngeal carcinoma

被引:10
|
作者
Zheng, Bao-min [1 ]
Dong, Xiao-xia [1 ]
Wu, Hao [1 ]
Duan, You-jia [1 ]
Han, Shu-kui [1 ]
Sun, Yan [1 ]
机构
[1] Peking Univ, Sch Oncol, Beijing Canc Hosp & Inst,Dept Radiotherapy, Key Lab Carcinogenesis & Translat Res,Minist Educ, Beijing 100142, Peoples R China
关键词
Volumetric modulated arc therapy; Intensity-modulated radiotherapy; Dosimetry; Target volume; Nasopharyngeal carcinoma; RADIOTHERAPY;
D O I
10.1007/s11670-011-0259-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A dosimetric study was performed to evaluate the performance of volumetric modulated arc radiotherapy with RapidArc on locally advanced nasopharyngeal carcinoma (NPC) The CT scan data sets of 20 patients of locally advanced NPC were selected randomly. The plans were managed using volumetric modulated arc with RapidArc and fixed nine-field coplanar dynamic intensity-modulated radiotherapy (IMRT) for these patients. The dosimetry of the planning target volumes (PTV), the organs at risk (OARs) and the healthy tissue were evaluated. The dose prescription was set to 70 Gy to the primary tumor and 60 Gy to the clinical target volumes (CTV) in 33 fractions. Each fraction applied daily, five fractions per week. The monitor unit (MU) values and the delivery time were scored to evaluate the expected treatment efficiency. Both techniques had reached clinical treatment's requirement. The mean dose (D-mean), maximum dose (D-max) and minimum dose (D-min) in RapidArc and fixed field IMRT for PTV were 68.4 +/- 0.6 Gy, 74.8 +/- 0.9 Gy and 56.8 +/- 1.1 Gy; and 67.6 +/- 0.6 Gy, 73.8 +/- 0.4 Gy and 57.5 +/- 0.6 Gy (P < 0.05), respectively. Homogeneity index was 78.85 +/- 1.29 in RapidArc and 80.34 +/- 0.54 (P < 0.05) in IMRT. The conformity index (CI: 95%) was 0.78 +/- 0.01 for both techniques (P > 0.05). Compared to IMRT, RapidArc allowed a reduction of D-mean to the brain stem, mandible and optic nerves of 14.1% (P < 0.05), 5.6% (P < 0.05) and 12.2% (P < 0.05), respectively. For the healthy tissue and the whole absorbed dose, D-mean of RapidArc was reduced by 3.6% (P < 0.05), and 3.7% (P < 0.05), respectively. The D-mean to the parotids, the spinal cord and the lens had no statistical difference among them. The mean MU values of RapidArc and IMRT were 550 and 1,379. The mean treatment time of RapidArc and IMRT was 165 s and 447 s. Compared to IMRT, the delivery time and the MU values of RapidArc were reduced by 63% and 60%, respectively. For locally advanced NPC, both RapidArc and IMRT reached the clinic requirement. The target volume coverage was similar for the different techniques. The RapidArc technique showed some improvements in OARs and other tissue sparing while using reduced MUs and delivery time.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 50 条
  • [41] A Dosimetric Study of Volumetric Modulated Arc Therapy (VMAT) Versus Intensity Modulated Radiation Therapy (IMRT) in Locally-Advanced Nasopharyngeal Cancer Involving Base of Skull
    Chakkabat, C.
    Tongtip, N.
    Amornwichet, N.
    Alisanant, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S723 - S723
  • [42] Dosimetric Comparison of Simultaneous Integrated Boost Treatment Plan Between Intensity Modulated Radiotherapies (IMRTs), Dual Arc Volumetric Modulated Arc Therapy (DA-VMAT) and Single Arc Volumetric Modulated Arc Therapy (SA-VMAT) for Nasopharyngeal Carcinoma (NPC)
    Sivakumar, R.
    Janardhan, N.
    Anuradha, C.
    Bhavani, P.
    Surendran, J.
    Saranganathan, B.
    Ibrahim, S.
    Jhonson, B.
    Madhuri, B.
    MEDICAL PHYSICS, 2015, 42 (06) : 3404 - 3404
  • [43] Volumetric Arc modulated Radiotherapy for carcinomas of the Oropharynx, Hypopharynx and Larynx. A Treatment Planning Dosimetric Comparison with Fixed Field IMRT
    Vanetti, E.
    Clivio, A.
    Nicolini, G.
    Fogliata, A.
    Ghosh-Laskar, S.
    Agarwal, J. P.
    Upreti, R.
    Budrukkar, A.
    Murthy, V.
    Deshpande, D.
    Shrivastava, S. K.
    Dinshaw, K. A.
    Cozzi, L.
    CLINICAL ONCOLOGY, 2009, 21 (03) : 246 - 246
  • [44] Comparison of Dynamic Volumetric Modulated Arc Therapy (VMAT) versus Static IMRT for Early-stage Larynx Cancer
    Riegel, A. C.
    Antone, J.
    Potters, L.
    Schwartz, D. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S520 - S520
  • [45] A phase II study of intensity modulated radiation therapy (IMRT) combined chemotherapy in local advanced nasopharyngeal carcinoma (NPC)
    Zhu, G.
    Wu, Y.
    Ying, H.
    He, X.
    Hu, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S467 - S468
  • [46] Comparison of dosimetric benefits in nasopharyngeal carcinoma patients among intensity-modulated radiotherapy, volumetric-modulated arc therapy and tomotherapy
    Xiong, W.
    Guoqiang, X.
    Wang, Q.
    Xu, T.
    Cao, R.
    Zhu, L.
    ANNALS OF ONCOLOGY, 2021, 32 : S793 - S793
  • [47] Total Scalp Irradiation Using Volumetric Modulated Arc Therapy and Comparison with IMRT and Conventional Photon/Electron Field Combination
    Wang, C.
    Wang, H.
    Tung, S.
    Chung, H.
    Wong, P.
    Martel, M.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [48] A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma
    Eldebawy E.
    Rashed Y.A.
    AlKhaldi M.
    Day E.
    Iranian Journal of Medical Physics, 2020, 17 (06) : 374 - 379
  • [49] Dosimetry study of nasopharyngeal carcinoma based on Halcyon accelerator fixed-field intensity-modulated radiation therapy
    Li, Kuo
    Li, Chengqiang
    Zhu, Ting
    Chen, Jinhu
    Cao, Wentao
    Yin, Yong
    Ma, Changsheng
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (05) : 1165 - 1171
  • [50] A Dosimetric Comparison of Split-Field IMRT, Whole-Field IMRT, and Volumetric Modulated Arc Therapy for Patients With Early-Stage Tonsillar Cancer
    Moreno, A. C.
    Wilke, C. T., Jr.
    Wang, H.
    Phan, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (05): : 1339 - 1339