The five percent electrode system for high-resolution EEG and ERP measurements

被引:1397
|
作者
Oostenveld, R
Praamstra, P
机构
[1] Univ Nijmegen Hosp, Inst Neurol, Dept Clin Neurophysiol, NL-6500 HB Nijmegen, Netherlands
[2] Univ Nijmegen, Dept Med & Biophys, Nijmegen, Netherlands
[3] Univ Birmingham, Behav Brain Sci Ctr, Birmingham, W Midlands, England
关键词
electrode placement; high resolution EEG; high resolution ERP; nomenclature;
D O I
10.1016/S1388-2457(00)00527-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: A system for electrode placement is described. It is designed for studies on topography and source analysis of spontaneous and evoked EEG activity. Method: The proposed system is based on the extended International 10-20 system which contains 74 electrodes, and extends this system up to 345 electrode locations. Results: The positioning and nomenclature of the electrode system is described, and a subset of locations is proposed as especially useful for modern EEG/ERP systems, often having 128 channels available. Conclusion: Similar to the extension of the 10-20 system to the 10-10 system ('10% system'), proposed in 1985, the goal of this new extension to a 10-5 system is to further promote standardization in high-resolution EEG studies. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:713 / 719
页数:7
相关论文
共 50 条
  • [21] High-resolution magnetic measurements of HTSC
    Janu, Zdenek
    Novak, Miloslav
    Tsoi, Georgiy
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2004, 272 : E1099 - E1101
  • [22] HIGH-RESOLUTION ELECTROREFLECTANCE MEASUREMENTS OF GAAS
    ASPNES, DE
    STUDNA, AA
    SURFACE SCIENCE, 1973, 37 (01) : 631 - 638
  • [23] HIGH-RESOLUTION PHOTOEMISSION MEASUREMENTS ON EUO
    COTTI, P
    MUNZ, P
    HELVETICA PHYSICA ACTA, 1972, 45 (01): : 19 - &
  • [24] PLOIDY MEASUREMENTS BY HIGH-RESOLUTION CYTOMETRY
    BIBBO, M
    BARTELS, PH
    DYTCH, HE
    WIED, GL
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1985, 7 (02): : 81 - 88
  • [25] HIGH-RESOLUTION ELECTROREFLECTANCE MEASUREMENTS OF GE
    ASPNES, DE
    STUDNA, AA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (03): : 438 - 438
  • [26] Source analysis of EEG oscillations using high-resolution EEG and MEG
    Srinivasan, Ramesh
    Winter, William R.
    Nunez, Paul L.
    EVENT-RELATED DYNAMICS OF BRAIN OSCILLATIONS, 2006, 159 : 29 - 42
  • [27] High-resolution ion mobility measurements
    Dugourd, P
    Hudgins, RR
    Clemmer, DE
    Jarrold, MF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (02): : 1122 - 1129
  • [28] HIGH-RESOLUTION MEASUREMENTS WITH A TANDEM ACCELERATOR
    BILPUCH, EG
    PURSER, FO
    MOSES, JD
    HAYWARD, TD
    NEWSON, HW
    MITCHELL, GE
    OUTLAW, DA
    NELSON, RO
    NUCLEAR INSTRUMENTS & METHODS, 1973, 113 (04): : 603 - 604
  • [29] HIGH-RESOLUTION MEASUREMENTS OF PLASMA DENSITY
    WATSON, JL
    BEACH, AD
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1969, 2 (01) : 129 - &
  • [30] A Very High Density Floating Electrode Flexible Sensor Array for High-Resolution Measurements of Contact Forces
    Surapaneni, Rajesh
    Guo, Qingbo
    Young, Darrin J.
    Mastrangelo, Carlos H.
    2013 IEEE SENSORS, 2013, : 871 - 874