The five percent electrode system for high-resolution EEG and ERP measurements

被引:1397
|
作者
Oostenveld, R
Praamstra, P
机构
[1] Univ Nijmegen Hosp, Inst Neurol, Dept Clin Neurophysiol, NL-6500 HB Nijmegen, Netherlands
[2] Univ Nijmegen, Dept Med & Biophys, Nijmegen, Netherlands
[3] Univ Birmingham, Behav Brain Sci Ctr, Birmingham, W Midlands, England
关键词
electrode placement; high resolution EEG; high resolution ERP; nomenclature;
D O I
10.1016/S1388-2457(00)00527-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: A system for electrode placement is described. It is designed for studies on topography and source analysis of spontaneous and evoked EEG activity. Method: The proposed system is based on the extended International 10-20 system which contains 74 electrodes, and extends this system up to 345 electrode locations. Results: The positioning and nomenclature of the electrode system is described, and a subset of locations is proposed as especially useful for modern EEG/ERP systems, often having 128 channels available. Conclusion: Similar to the extension of the 10-20 system to the 10-10 system ('10% system'), proposed in 1985, the goal of this new extension to a 10-5 system is to further promote standardization in high-resolution EEG studies. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:713 / 719
页数:7
相关论文
共 50 条
  • [1] The Estimation of Cortical Connectivity from High-Resolution EEG Measurements
    Babiloni, F.
    NEUROPSYCHOBIOLOGY, 2008, 58 (3-4) : 237 - 237
  • [2] High-Resolution EEG Recording System using Smart Electrodes
    Malmivuo, Jaakko
    Ahokas, Sari
    Valkky, Toni
    2014 PROCEEDINGS OF THE 14TH BIENNIAL BALTIC ELECTRONICS CONFERENCE (BEC 2014), 2014, : 21 - 24
  • [3] Ag-AgCl electrode noise in high-resolution ECG measurements
    Fernandez, M. (mireya@eel.upc.es), 2000, Association for the Advancement of Medical Instrumentation (34):
  • [4] A high-resolution β - γ coincidence spectrometry system for radioxenon measurements
    Goodwin, M. A.
    Britton, R.
    Davies, A., V
    Bell, S. J.
    Collins, S. M.
    Regan, P. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 978
  • [5] Conductivity analysis for high-resolution EEG
    Turovets, Sergei I.
    Poolman, Pieter
    Salman, Adnan
    Malony, Allen D.
    Tucker, Don M.
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 386 - +
  • [6] On the realization of an analytic high-resolution EEG
    Edlinger, G
    Wach, P
    Pfurtscheller, G
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (06) : 736 - 745
  • [7] HIGH-RESOLUTION OTDR MEASUREMENTS
    GARSIDE, BK
    PHOTONICS SPECTRA, 1988, 22 (09) : 79 - &
  • [8] High-resolution temperature measurements
    IPITEK, Carlsbad, United States
    Am Lab, 15 (6pp):
  • [9] HIGH-RESOLUTION SYSTEM FOR TROPOSPHERIC WIND AND TEMPERATURE PROFILE MEASUREMENTS
    CAMP, DW
    VAUGHAN, WW
    JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS AND ATMOSPHERES, 1975, 80 (27): : 3797 - 3800
  • [10] Coherent heterodyne detection system for high-resolution BSDF measurements
    Neubert, J
    Schulz, U
    OPTICAL SYSTEM CONTAMINATION V AND STRAY LIGHT AND SYSTEM OPTIMIZATION, 1996, 2864 : 322 - 332