Monitoring of a Tall Building Equipped with an Efficient Multiple-Tuned Sloshing Damper System

被引:17
|
作者
Love, J. S. [1 ]
Morava, B. [1 ]
Smith, A. W. [1 ]
机构
[1] RWDI Inc, 600 Southgate Dr, Guelph, ON N1G 4P6, Canada
关键词
Structural monitoring; Multiple tuned sloshing damper; Wind-induced motion; Wind tunnel testing; Structural control; Added effective damping; TLD;
D O I
10.1061/(ASCE)SC.1943-5576.0000481
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An efficient multiple tuned sloshing damper (MTSD) system is installed in a tall building in Toronto, Canada. The building is monitored before and after water is added to the tanks to measure wind-induced building motion, and evaluate the performance of the MTSD. To the authors' knowledge, this is the first time an MTSD system has been installed in a tall building, and one of the few times the as-built performance of a tall building supplementary damping system has been evaluated and reported in the literature. Monitoring of the building motion before commissioning the MTSD indicated that the structural frequencies were very close to those originally predicted by the structural engineer's finite element model. Only 0.8% inherent structural damping was measured for the first mode when the peak building acceleration was 7 milli-g. The measured and wind tunnel predicted wind-induced building accelerations are in good agreement. After commissioning the MTSD system, the measured building accelerations and MTSD wave heights are found to be well-aligned with predictions. Several techniques are used to evaluate the performance of the MTSD system using the measured data. Each technique confirms that the MTSD system reduced building accelerations by approximately 50%. Full-scale structural monitoring has therefore shown that MTSDs can significantly reduce the motion of tall buildings.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Dynamic performance of a supertall building with an active tuned mass damper system during Super Typhoon Saola
    Xu, Kang
    Li, Qiusheng
    Zhou, Kang
    Han, Xuliang
    ENGINEERING STRUCTURES, 2024, 318
  • [42] Online Adaptive Neurochaotic Fuzzy Controller Design to Reduce the Seismic Response of Buildings Equipped with Active Tuned Mass Damper System
    Jafarzadeh, Ommegolsoum
    Ghasemi, Seyyed Arash Mousavi
    Zahrai, Seyed Mehdi
    Mohammadzadeh, Ardashir
    Poursorkhabi, Ramin Vafaei
    INTERNATIONAL JOURNAL OF INTELLIGENT SYSTEMS, 2023, 2023
  • [43] Top-Story Softening for Enhanced Mitigation of Vortex Shedding-Induced Vibrations in Wind-Excited Tuned Mass Damper Inerter-Equipped Tall Buildings
    Wang, Zixiao
    Giaralis, Agathoklis
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (01)
  • [44] Seismic performance evaluation of a tall building with dual lateral system consisting of moment frames and tuned mass dampers
    Matinrad P.
    Banazadeh M.
    Taslimi A.
    Asian Journal of Civil Engineering, 2024, 25 (1) : 1 - 17
  • [45] Design of an energy efficient building equipped with air conditioning system for growing "Kladnitsa" mushrooms
    Dimova, Vanya
    Georgiev, Dimitar
    Georgiev, Rashko
    Grigorov, Stoyan
    BULGARIAN JOURNAL OF AGRICULTURAL SCIENCE, 2020, 26 : 221 - 228
  • [46] Experience with RTK-GPS system for monitoring wind and seismic effects on a tall building
    Brownjohn, J. M. W.
    Stringer, M.
    Tan, G. H.
    Poh, Y. K.
    Ge, L.
    Pan, T. C.
    STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2006, : 265 - 275
  • [47] Real-time performance monitoring of tuned mass damper system for a 183 m reinforced concrete chimney
    Brownjohn, J. M. W.
    Carden, E. P.
    Goddard, C. R.
    Oudin, G.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2010, 98 (03) : 169 - 179
  • [48] Shaking table test and numerical analysis of a coal-fired power plant equipped with large mass ratio multiple tuned mass damper (LMTMD)
    Kang, Ying-jie
    Peng, Ling-yun
    Pan, Peng
    Xiao, Gen-qi
    Wang, Hai-shen
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [49] Vibration mitigation performance of active tuned mass damper in a super high-rise building during multiple tropical storms
    Zhou, Kang
    Li, Qiu-Sheng
    ENGINEERING STRUCTURES, 2022, 269
  • [50] Optimum seismic design of a power plant building with pendulum tuned mass damper system by its heavy suspended buckets
    Shu, Zhan
    Li, Shuang
    Zhang, Jian
    He, Minjuan
    ENGINEERING STRUCTURES, 2017, 136 : 114 - 132