Groundwater microbiological quality in Canadian drinking water municipal wells

被引:0
|
作者
Locas, Annie [1 ]
Barthe, Christine [2 ]
Margolin, Aaron B. [3 ]
Payment, Pierre [1 ]
机构
[1] INRS, Inst Armand Frappier, Laval, PQ H7V 1B7, Canada
[2] Direct Lab Expertises & Anal Alimentaires, Minist Agr Pecheries & Alimentat Quebec, Quebec City, PQ G19 3W8, Canada
[3] Univ New Hampshire, Dept Microbiol, Durham, NH 03824 USA
关键词
water quality indicators; groundwater; drinking water; virus; total coliforms; E; coli;
D O I
10.1139/W08-028
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
To verify previous conclusions on the use of bacterial indicators suggested in regulations and to investigate virological quality of groundwater, a 1-year study was undertaken on groundwater used as a source of drinking water in 3 provinces in Canada. Raw water from 25 municipal wells was sampled during a 1-year period for a total of 167 samples. Twenty-three sites were selected on the basis of their excellent historical bacteriological water quality data, and 2 sites with known bacteriological contamination were selected as positive controls. Water samples were analyzed for general water quality indicators ( aerobic endospores, total coliforms), fecal indicators ( Escherichia coli, enterococci, somatic and male-specific coliphages), total culturable human enteric viruses ( determined by cell culture and immunoperoxidase), noroviruses ( analyzed by reverse-transcriptase-polymerase chain reaction (RT-PCR)), adenovirus types 40 and 41 ( analyzed by integrated cell culture (ICC)-PCR), and enteroviruses and reoviruses types 1, 2, and 3 ( analyzed by ICC-RT-PCR). General water quality indicators were found very occasionally at the clean sites but were frequently present at the 2 contaminated sites. Only one of 129 samples from the 23 clean sites was positive for enterococci. These results confirm the value of raw water quality historical data to detect source water contamination affecting wells that are vulnerable. Samples from the 2 contaminated sites confirmed the frequent presence of fecal indicators: E. coli was found in 20/38 samples and enterococci in 12/38 samples. Human enteric viruses were not detected by cell culture on MA-104 cells nor by immunoperoxidase detection in any sample from the clean sites but were found at one contaminated site. By ICC-RT-PCR and ICC-PCR, viruses were found by cytopathic effect in one sample from a clean site and they were found in 3 samples from contaminated sites. The viruses were not detected by the molecular methods but were confirmed as picornaviruses by electron microscopy. Noroviruses were not detected in any samples. The results obtained reinforce the value of frequent sampling of raw water using simple parameters: sampling for total coliforms and E. coli remains the best approach to detect contamination of source water by fecal pollutants and accompanying pathogens. The absence of total coliforms at a site appears to be a good indication of the absence of human enteric viruses.
引用
收藏
页码:472 / 478
页数:7
相关论文
共 50 条
  • [31] Influence of microbiological quality of drinking water in the intestinal morphology of broilers
    Amoroso, Lizandra
    Baraldi-Artoni, Silvana M.
    Soares, Nilce M.
    Pinto, Fernanda R.
    Pacheco, Maria R.
    Sagula, Alex L.
    Rios Alva, Juan Carlos
    Amoroso, Patricia
    PESQUISA VETERINARIA BRASILEIRA, 2015, 35 (01): : 80 - 88
  • [32] Microbiological quality of drinking water in urban communities, Rawalpindi, Pakistan
    Hashmi, Imran
    Qaiser, Sara
    Farooq, Shaukat
    DESALINATION AND WATER TREATMENT, 2012, 41 (1-3) : 240 - 248
  • [33] Microbiological quality of drinking water in South-Western Greece
    Papapetropoulou, M
    Pagonopoulou, O
    WATER AIR AND SOIL POLLUTION, 1998, 101 (1-4): : 15 - 24
  • [34] Methods for microbiological quality assessment in drinking water: a comparative study
    Helmi, K.
    Barthod, F.
    Meheut, G.
    Henry, A.
    Poty, F.
    Laurent, F.
    Charni-Ben-Tabassi, N.
    JOURNAL OF WATER AND HEALTH, 2015, 13 (01) : 34 - 41
  • [35] The microbiological quality of drinking water sold on the streets in Kumasi, Ghana
    Obiri-Danso, K
    Okore-Hanson, A
    Jones, K
    LETTERS IN APPLIED MICROBIOLOGY, 2003, 37 (04) : 334 - 339
  • [36] COMPARISON OF THE MICROBIOLOGICAL QUALITY OF WATER-COOLERS AND THAT OF MUNICIPAL WATER-SYSTEMS
    LEVESQUE, B
    SIMARD, P
    GAUVIN, D
    GINGRAS, S
    DEWAILLY, E
    LETARTE, R
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1994, 60 (04) : 1174 - 1178
  • [37] MICROBIOLOGICAL QUALITY OF RESIDUES FROM DRINKING-WATER PREPARATION
    WURZER, M
    WIEDENMANN, A
    BOTZENHART, K
    WATER SCIENCE AND TECHNOLOGY, 1995, 31 (5-6) : 75 - 79
  • [38] Microbiological quality of drinking water of urban and rural communities, Brazil
    Nogueira, G
    Nakamura, CV
    Tognim, MCB
    Filho, BAA
    Filho, BPD
    REVISTA DE SAUDE PUBLICA, 2003, 37 (02): : 232 - 236
  • [39] Microbiological Quality of Drinking Water in South-Western Greece
    Maria Papapetropoulou
    Olga Pagonopoulou
    Water, Air, and Soil Pollution, 1998, 101 : 15 - 24
  • [40] THE NEW GUIDELINES FOR CANADIAN DRINKING-WATER QUALITY
    HICKMAN, JR
    TOFT, P
    ARMSTRONG, VC
    MEEK, ME
    DRINKING WATER TREATMENT: SMALL SYSTEM ALTERNATIVES, 1989, : 16 - 25