Physiological noise in oxygenation-sensitive magnetic resonance imaging

被引:492
|
作者
Krüger, G [1 ]
Glover, GH [1 ]
机构
[1] Stanford Univ, Dept Radiol, Lucas MRS Ctr, Palo Alto, CA 94304 USA
关键词
neuroimaging; spiral scan; magnetic field strength; SNR; physiological noise;
D O I
10.1002/mrm.1240
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The physiological noise in the resting brain, which arises from fluctuations in metabolic-linked brain physiology and subtle brain pulsations, was investigated in six healthy volunteers using oxygenation-sensitive dual-echo spiral MRI at 3.0 T. In contrast to the system and thermal noise, the physiological noise demonstrates a signal strength dependency and, unique to the metabolic-linked noise, an echo-time dependency. Variations of the MR signal strength by changing the flip angle and echo time allowed separation of the different noise components and revealed that the physiological noise at 3.0 T (1) exceeds other noise sources and (2) is significantly greater in cortical gray matter than in white matter regions. The SNR in oxygenation-sensitive MRI is predicted to saturate at higher fields, suggesting that noise measurements of the resting brain at 3.0 T and higher may provide a sensitive probe of functional information. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:631 / 637
页数:7
相关论文
共 50 条
  • [41] Myocardial intensity changes associated with flow stimulation in blood oxygenation sensitive magnetic resonance imaging
    Niemi, P
    Poncelet, BP
    Kwong, KK
    Weisskoff, RM
    Rosen, BR
    Brady, TJ
    Kantor, HL
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) : 78 - 82
  • [42] Stimulus dependence of oxygenation-sensitive MRI responses to sustained visual activation
    Kruger, G
    Kleinschmidt, A
    Frahm, J
    NMR IN BIOMEDICINE, 1998, 11 (02) : 75 - 79
  • [43] Renal Blood Oxygenation Level-Dependent Magnetic Resonance Imaging A Sensitive and Objective Analysis
    Thacker, Jon M.
    Li, Lu-Ping
    Li, Wei
    Zhou, Ying
    Sprague, Stuart M.
    Prasad, Pottumarthi V.
    INVESTIGATIVE RADIOLOGY, 2015, 50 (12) : 821 - 827
  • [44] Temporal characteristics of oxygenation-sensitive MRI responses to visual activation in humans
    Fransson, P
    Krüger, G
    Merboldt, KD
    Frahm, J
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) : 912 - 919
  • [45] Dynamic imaging of perfusion and oxygenation by functional magnetic resonance imaging
    Kida, I
    Maciejewski, TK
    Hyder, F
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2004, 24 (12): : 1369 - 1381
  • [46] Oxygenation-sensitive cardiovascular magnetic resonance in hypertensive heart disease with left ventricular myocardial hypertrophy and non-left ventricular myocardial hypertrophy: Insight from altered mechanics and cardiac BOLD imaging
    Chen, Bing-Hua
    Wu, Rui
    An, Dong-Aolei
    Shi, Ruo-Yang
    Yao, Qiu-Ying
    Lu, Qing
    Hu, Jiani
    Jiang, Meng
    Deen, James
    Chandra, Ankush
    Xu, Jian-Rong
    Wu, Lian-Ming
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (05) : 1297 - 1306
  • [47] Magnetic resonance imaging of oxygenation in human brain and tumors
    Yetkin, FZ
    Mendelsohn, D
    Purdy, P
    McColl, R
    RADIOLOGY, 2001, 218 (02) : 614 - 614
  • [48] Impact of hyperventilation and apnea on myocardial oxygenation in patients with obstructive sleep apnea - An oxygenation-sensitive CMR study
    Roubille, Francois
    Fischer, Kady
    Guensch, Dominik P.
    Tardif, Jean-Claude
    Friedrich, Matthias G.
    JOURNAL OF CARDIOLOGY, 2017, 69 (1-2) : 489 - 494
  • [49] Magnetic resonance imaging of tumor oxygenation and metabolic profile
    Krishna, Murali C.
    Matsumoto, Shingo
    Saito, Keita
    Matsuo, Masayuki
    Mitchell, James B.
    Ardenkjaer-Larsen, Jan H.
    ACTA ONCOLOGICA, 2013, 52 (07) : 1248 - 1256
  • [50] Analysis of physiological noise in quantitative cardiac magnetic resonance
    Jao, Terrence
    Nayak, Krishna
    PLOS ONE, 2019, 14 (08):