Focused microwave-assisted digestion of biological reference materials for the determination of trace metals by ICP-MS

被引:0
|
作者
Garraud, H [1 ]
Robert, M [1 ]
Quetel, CR [1 ]
Szpunar, J [1 ]
Donard, OFX [1 ]
机构
[1] CNRS EP 132, LAB CHIM BIOINORGAN & ENVIRONM, F-64000 PAU, FRANCE
关键词
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A rapid method for the preparation. of biological materials based on their digestion in a low power-focused microwave system prior to ICP-MS was developed. The samples were decomposed using a three-step attack with 30% nitric acid at (a) 30 W for five minutes, (b) 50 W for six minutes, and (c) 80 W for six minutes. This was followed by cooling the mixture and subsequently attacking with a 15% solution of hydrogen peroxide at 30 W for five minutes. The resultant solution was diluted with 2% nitric acid and aspirated to the nebulizer. Eight elements (Mg, Mn, Ni, Cu, Zn, As, Sr, and Cd) were determined simultaneously using the peak hopping mode and external calibration of the ICP-MS. The method was validated by the analysis of four NRCC reference materials: LUTS-1 and TORT-1 (lobster hepato-pancreas), DORM-1 (dogfish muscle), and DOLT-2 (dogfish liver).
引用
收藏
页码:183 / 185
页数:3
相关论文
共 50 条
  • [31] Determination of Bromine in Plastics by ICP-MS Using Microwave Digestion
    Matsumoto, Akihiro
    Osaki, Shusuke
    Kobata, Toshitsugu
    Tanigughi, Hisaji
    BUNSEKI KAGAKU, 2014, 63 (02) : 147 - 150
  • [32] Microwave-assisted volatilization of chlorides of Ge and Se for the determination of trace impurities in high purity Ge and Se by ICP-MS
    Ueng, RL
    Sahayam, AC
    Jiang, SJ
    Wan, CC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (05) : 681 - 684
  • [33] Microwave-assisted volatilization of silicon fluorides for the determination of trace impurities in high purity silicon powder and quartz by ICP-MS
    Ueng, RL
    Jiang, SJ
    Wan, CC
    Sahayam, AC
    ANALYTICA CHIMICA ACTA, 2005, 536 (1-2) : 295 - 299
  • [35] Simple, fast, and low-contamination microwave-assisted digestion procedures for the determination of chemical elements in biological and environmental matrices by sector field ICP-MS
    Bocca, Beatrice
    Conti, Marcelo Enrique
    Pino, Anna
    Mattei, Daniela
    Forte, Giovanni
    Alimonti, Alessandro
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2007, 87 (15) : 1111 - 1123
  • [36] DETERMINATION OF TRACE-ELEMENTS IN 11 CHINESE GEOLOGICAL REFERENCE MATERIALS BY ICP-MS
    TANG, YQ
    JARVIS, KE
    WILLIAMS, JG
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1992, 16 (01): : 61 - 70
  • [37] Determination of trace metals in electrolytic copper by ICPOES and ICP-MS
    dos Santos, ÉJ
    Herrmann, AB
    Olkuszewski, JL
    Saint'Pierre, TD
    Curtius, AJ
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2005, 48 (05) : 681 - 687
  • [38] Pretreatment of human hair for the determination of trace metals by ICP-MS
    Ortiz-Robles, C.
    Barrera-Hernandez, A.
    Sanchez-Pena, C.
    Marquez-Herrera, C.
    Lopez-Bayghen, E.
    Quintanilla-Vega, B.
    Del Razo, L. M.
    TOXICOLOGY LETTERS, 2016, 259 : S89 - S89
  • [39] Validation of an optimised microwave-assisted acid digestion method for trace and ultra-trace elements in indoor PM2.5 by ICP-MS analysis
    Camilleri, Renato
    Stark, Christopher
    Vella, Alfred J.
    Harrison, Roy M.
    Aquilina, Noel J.
    HELIYON, 2023, 9 (01)
  • [40] Comparison of Microwave-Assisted Digestion Methods and Selection of Internal Standards for the Determination of Rh, Pd and Pt in Dust Samples by ICP-MS
    Matti Niemelä
    Harri Kola
    Paavo Perämäki
    Juha Piispanen
    Jarmo Poikolainen
    Microchimica Acta, 2005, 150 : 211 - 217