Multidistance probe arrangement to eliminate motion artifacts in fNIRS

被引:3
|
作者
Yamada, Toru [1 ]
Umeyama, Shinji [1 ]
Matsuda, Keiji [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Neurosci Res Inst, Tsukuba, Ibaraki 3058568, Japan
关键词
NIRS; multidistance probe arrangement; cerebral activity; motion artifacts; systemic response; two-layered optical media; NEAR-INFRARED SPECTROSCOPY; TISSUE; ADULT;
D O I
10.1117/12.808616
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Functional near-infrared spectroscopy (fNIRS) has the potential of easily detecting cerebral activity. However, in practical fNIRS measurements, a subject's physical or physiological changes such as body movements have often caused serious problems. If such a change is evoked by the tasks being monitored, it strongly correlates with the task sequence, and its interference in fNIRS cannot be eliminated using conventional signal filtering techniques. Hence, further improvement is necessary to eliminate such interference if we intend to use fNIRS on subjects with little or no physical restraint such as infants. We introduced an additional detector (d(2)) between the source and detector (d(1)) positioned in a conventional arrangement. The distances from the source to the detector d(1) and d(2) were set at 30 mm and 20 mm, respectively. Concentration changes of oxygenated and deoxygenated hemoglobin (Delta HbO and Delta HbR) were calculated using the linear combination of absorbance changes at d(1) and d(2). Then tasks such as the upper-body tilting, the head nodding, the breath holding, and the finger opposition were performed by the participant. The statistical significance of the difference in concentration changes of Delta HbO and Delta HbR between task and rest periods was examined using the paired t-test. The results showed that interference due to upper-body tilting, head nodding, and breath holding was reduced by this method. Moreover, in the finger opposition task, a simultaneous increase of Delta HbO and decrease of Delta HbR was observed and these were significantly localized in the activation area by this method.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Heart Rate Monitoring Using a Slow-Fast Adaptive Comb Filter to Eliminate Motion Artifacts
    Chuang, Cheng-Ta
    Chang, Tom
    Chiang, Yi-Te
    Chang, Fan-Ren
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (06) : 833 - 842
  • [22] The use of modified primers to eliminate cycle sequencing artifacts
    Stump, MD
    Cherry, JL
    Weiss, RB
    NUCLEIC ACIDS RESEARCH, 1999, 27 (23) : 4642 - 4648
  • [23] Development of a miniaturized and modular probe for fNIRS instrument
    Liu, Guangda
    Cui, Wenjie
    Hu, Xinlei
    Xiao, Ruolan
    Zhang, Shang
    Cai, Jing
    Qiu, Jiqing
    Qi, Yuan
    LASERS IN MEDICAL SCIENCE, 2022, 37 (04) : 2269 - 2277
  • [24] Biomimetic sonar and neuromorphic processing eliminate reverberation artifacts
    Kuc, Roman
    IEEE SENSORS JOURNAL, 2007, 7 (3-4) : 361 - 369
  • [25] AN IMMUNOELECTROPHORESIS SYSTEM INCORPORATING A TEMPLATE TO ELIMINATE THROUGH ARTIFACTS
    BURKE, M
    MACY, J
    SABER, A
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1174 - 1174
  • [26] Development of a miniaturized and modular probe for fNIRS instrument
    Guangda Liu
    Wenjie Cui
    Xinlei Hu
    Ruolan Xiao
    Shang Zhang
    Jing Cai
    Jiqing Qiu
    Yuan Qi
    Lasers in Medical Science, 2022, 37 : 2269 - 2277
  • [27] A Model-Free Approach to Probe Motion Artifacts Suppression for in vivo Imaging with Probe Oscillation Shear Wave Elastography (PROSE)
    Mellema, Daniel C.
    Song, Pengfei
    Manduca, Armando
    Urban, Matthew W.
    Kinnick, Randall R.
    Greenleaf, James F.
    Chen, Shigao
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [28] THE VISIBILITY OF MOTION ARTIFACTS AND THEIR EFFECT ON MOTION QUALITY
    Mackin, Alex
    Noland, Katy C.
    Bull, David R.
    2016 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2016, : 2435 - 2439
  • [29] Hand Motion Detection in fNIRS Neuroimaging Data
    Abtahi, Mohammadreza
    Amiri, Amir Mohammad
    Byrd, Dennis
    Mankodiya, Kunal
    HEALTHCARE, 2017, 5 (02)
  • [30] Artifacts in body MR imaging: their appearance and how to eliminate them
    Stadler, Alfred
    Schima, Wolfgang
    Ba-Ssalamah, Ahmed
    Kettenbach, Joachim
    Eisenhuber, Edith
    EUROPEAN RADIOLOGY, 2007, 17 (05) : 1242 - 1255