Experimental study of a fabricated confined concrete beam-to-column connection with end-plates

被引:57
|
作者
Li Shufeng [1 ]
Li Qingning [1 ]
Zhang Hao [1 ]
Jiang Haotian [1 ]
Yan Lei [2 ]
Jiang Weishan [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Shaanxi, Peoples R China
[2] Chongqing Three Gorges Univ, Coll Civil Engn, Chongqing 404100, Peoples R China
关键词
Construction industry; Fabricated beam-column connections; Seismic behavior; Flexural capacity; Plastic zone; PRECAST; PERFORMANCE; MOMENT; JOINTS;
D O I
10.1016/j.conbuildmat.2017.10.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
At present, the building industrialization has become the development direction of construction industry, the precast prefabricated buildings become the focus of the construction industry once again because of its unique characteristics. A new-type of fabricated beam-column connections with end-plates is presented and introduced on this background. To investigate the seismic behavior of the new-type precast connection, seven specimens are tested by pseudo-static test. The hysteresis curves are recorded during the test, and the seismic indicators, such as ductility and energy dissipation capacity, are determined. The test results indicate that the hysteresis curves of precast connection are plump, and all specimens failed in bending in a malleable way with a beam plastic hinge, which is fully consistent with the criterion of strong column weak beams. Additionally, the fabricated connection exhibits satisfactory ductility and energy dissipation capacity, showing better seismic performance. Besides, the flexural capacity of unbonded prestressed confined concrete beam is analyzed, and the formula of flexural bearing capacity is proposed based on the theory of concentrated plastic zone. The theoretical results agree well with the experimental data, which can provide reference for theoretical research. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:208 / 216
页数:9
相关论文
共 50 条
  • [31] Experimental study on seismic performance of precast-prestressed beam-to-column concrete connections
    Li, Zhen-Bao
    Dong, Ting-Feng
    Ma, Hua
    Feng, Li-Feng
    Bai, Cong-Min
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1650 - 1657
  • [32] External precast concrete nib beam-to-column connection under elevated temperatures: Experimental and finite element analysis
    Radzi, Noor Azim Mohd.
    Hamid, Roszilah
    Mutalib, Azrul A.
    Kaish, A. B. M. A.
    STRUCTURES, 2023, 57
  • [33] The experimental study on WF beam-to-column connection using special shaped high strength bolt
    Masuda, H
    Tanaka, A
    Fujii, S
    STESSA 2003: BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2003, : 847 - 851
  • [34] Experimental study on crack of hot dip galvanaized coatings of welded joint of beam-to-column connection
    Mori, Masanori
    Nakagomi, Tadao
    Fujita, Tetsuya
    Yosetsu Gakkai Shi/Journal of the Japan Welding Society, 2009, 78 (05): : 146 - 148
  • [35] Behavior of precast concrete beam-to-column connection with U- and L-bent bar anchorages placed outside the column panel - experimental study
    Wahjudi, Dicky Imam
    Suprobo, Priyo
    Sugihardjo, Hidajat
    Tavio
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS, 2014, 95 : 122 - 131
  • [36] Experimental study on the structural performance of non-intersection type steel beam-to-column connection
    Yamada S.
    Yoshie K.
    Kouno T.
    Kojima D.
    Journal of Structural and Construction Engineering, 2010, 75 (656): : 1901 - 1908
  • [37] Experimental study on crack of hot dip galvanaized coatings of welded joint of beam-to-column connection
    Takenaka Corp.
    不详
    不详
    Yosetsu Gakkai Shi, 2007, 5 (122-124):
  • [38] Application of stress diffusers to beam-to-column connection
    Dimitrakis, SD
    Lawrence, FV
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2002, 14 (01) : 84 - 89
  • [39] BEAM-TO-COLUMN CONNECTION RESEARCH IN JAPAN.
    Kato, Ben
    1982, 108 (ST2): : 343 - 360
  • [40] Steel Beam-To-Column Connection Fire Design
    Chloe, Jeanneret
    Austin, Martins-Robalino
    John, Gales
    Aikaterini, Genikomsou
    Panagiotis, Kotsovinos
    PROCEEDINGS OF THE CANADIAN SOCIETY OF CIVIL ENGINEERING ANNUAL CONFERENCE 2022, VOL 2, CSCE 2022, 2023, 348 : 121 - 135