Determination of methylparaben by differential pulse voltammetry using a glassy carbon electrode modified with polypyrrole

被引:17
|
作者
Madakbas, Seyfullah [1 ]
Kamiloglu, Senem [1 ]
Yetimoglu, Ece Kok [1 ]
机构
[1] Marmara Univ, Fac Art & Sci, Dept Chem, TR-34722 Istanbul, Turkey
关键词
differential pulse voltammetry; modified glassy carbon electrode; methylparaben; polypyrrole; PERFORMANCE LIQUID-CHROMATOGRAPHY; DOPED DIAMOND ELECTRODE; ELECTROCHEMICAL DETECTION; CONDUCTING POLYMER; METHYL PARABEN; SENSOR; COSMETICS; TYROSINE;
D O I
10.1134/S1061934815060155
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new modified glassy carbon electrode (GCE) based on a synthesized polypyrrole (PPy) was developed for the determination of methylparaben by differential pulse voltammetry (DPV). PPy was covalently immobilized on GCE surface using tetraethyl ammonium perchlorate (TEAP) and acetonitrile (ACN). Methylparaben was oxidized by differential pulse voltammetry and a peak was observed at 1.20 V. The calibration curve obtained with differential pulse voltammetry was linear in the concentration range from 0.01 to 5 mM methylparaben with a limit of detection of 8 x10(-3) mM and RSD of 0.11%. The improved method was applied to the determination of methylparaben in cream samples using the differential pulse voltammetry method.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 50 条
  • [21] Differential pulse voltammetry determination of acetaminophen and codeine in pharmaceutical formulations using a Mn/UiO-66 modified glassy carbon electrode
    Tran Duc Manh
    Vo Thang Nguyen
    Vu Thi Duyen
    Nguyen Thi Thy Nga
    Nguyen Quang Man
    Pham Thi Huyen Thoa
    Le Huu Trinh
    Dinh Quang Khieu
    Journal of Nanoparticle Research, 2023, 25
  • [22] Determination of U(VI) by differential pulse stripping voltammetry using a polydopamine/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Guo, Weihua
    Xu, Huiling
    Chen, Cheng
    Cao, Xiaohong
    Ma, Jianguo
    Liu, Yunhai
    MICROCHEMICAL JOURNAL, 2022, 175
  • [23] Determination of Folic Acid in Food by Differential Pulse Voltammetry with ZnO@GO Nanocomposites Modified Glassy Carbon Electrode
    Ma, Jing Xi
    Yang, Liu
    Wang, Lei
    Wu, Shu Qing
    Liu, Yan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (01): : 1 - 12
  • [24] Electroanalytical Determination of Ziram by Differential Pulse Voltammetry with Reduced Graphene Oxide/Gold Nanoparticles Modified Glassy Carbon Electrode
    Aslan, Nazife
    Ocak, Sema Bilge
    Gokmen, Ugur
    ACTA CHIMICA SLOVENICA, 2022, 69 (03) : 638 - 646
  • [25] Determination of the Anticancer Drug Sorafenib in Serum by Adsorptive Stripping Differential Pulse Voltammetry Using a Chitosan/Multiwall Carbon Nanotube Modified Glassy Carbon Electrode
    Karadas-Bakirhan, Nurgul
    Patris, Stephanie
    Ozkan, Sibel A.
    Can, Alp
    Kauffmann, Jean-Michel
    ELECTROANALYSIS, 2016, 28 (02) : 358 - 365
  • [26] DETERMINATION OF DRIMARENE BLUE X-BLN AT A GLASSY CARBON ELECTRODE BY DIFFERENTIAL PULSE VOLTAMMETRY
    Radi, Abd-Elgawad M.
    Mostafa, Mohammed R.
    Elshafey, Reda M.
    Hegazy, Talaat A.
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2011, 76 (12) : 1765 - 1773
  • [27] Electrochemical Determination of Imidacloprid Using an Electrosynthesized Hexa-Peri-Hexabenzocoronene Modified Glassy Carbon Electrode (GCE) by Differential Pulse Voltammetry (DPV)
    Wang, Rong
    Lin, Tingting
    Nie, Qiyang
    Qin, Caihong
    Luo, Yougang
    Wang, Ruijuan
    Wang, Shulong
    Jing, Yiqi
    ANALYTICAL LETTERS, 2024, 57 (18) : 3103 - 3114
  • [28] Simultaneous Determination of Benserazide and Levodopa in Pharmaceutical Tablet, Human Serum and Urine Sample by Differential Pulse Voltammetry Using Modified Glassy Carbon Electrode
    Naushad, Mu.
    Gupta, V. K.
    Wabaidur, S. M.
    Alothman, Z. A.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (01): : 297 - 311
  • [29] Determination of Cadmium(II) by Differential Pulse Voltammetry (DPV) Using a Cerium(IV) Oxide: Polyaniline Composite Modified Glassy Carbon Electrode (GCE)
    Altundal, Melis
    Uge, Ahmet
    Gok, Ozer
    Zeybek, Bulent
    ANALYTICAL LETTERS, 2021, 54 (15) : 2431 - 2451
  • [30] Determination of the herbicide paraquat using the new Ag-GO/CuO/GCE-modified glassy carbon electrode by differential pulse voltammetry
    Savary, Abdolrahman
    Yari, Abdollah
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2021, 68 (10) : 1987 - 1997