A novel hypothermic machine perfusion system using a LifePort Kidney Transporter for the preservation of rat liver

被引:4
|
作者
Zeng, Cheng [1 ,2 ,3 ]
Hu, Xiaoyan [1 ,2 ,3 ]
Wang, Yanfeng [1 ,2 ,3 ]
Zeng, Xianpeng [1 ,2 ,3 ]
Xiong, Yan [1 ,2 ,3 ]
Li, Ling [1 ,2 ,3 ]
Ye, Qifa [1 ,2 ,3 ,4 ]
机构
[1] Wuhan Univ, Zhongnan Hosp, Transplant Ctr, 169 Donghu Rd, Wuhan 430071, Hubei, Peoples R China
[2] Wuhan Univ, Inst Hepatobiliary Dis, Wuhan 430071, Hubei, Peoples R China
[3] Wuhan Univ, Zhongnan Hosp, Hubei Key Lab Med Technol Transplantat, Wuhan 430071, Hubei, Peoples R China
[4] Cent S Univ, Xiangya Hosp 3, Natl Hlth Minist Transplantat Med Engn & Technol, Res Ctr, Changsha 410013, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
hypothermic machine perfusion; preservation; liver transplantation; COLD PRESERVATION; FLUORESCENT DYES; CELL VIABILITY; TRANSPLANTATION; EXPERIENCE; DONORS; OXYGEN; DONATION; IMPACT; DEATH;
D O I
10.3892/etm.2017.5587
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The protective mechanisms for liver preservation associated with hypothermic machine perfusion (HMP) remain unclear. However, the lack of a common and portable HMP system for rat livers limits the study of HMP. The present study aimed to develop a novel, modified HMP system using a LifePort Kidney Transporter for preserving rat livers. A simple Y' shunt combined with a pressoreceptor for flow and pressure regulation was adapted to perfuse rat livers via the portal vein continuously using a LifePort Kidney Transporter under its prime mode' setting. An electronic scale was installed under the liver container to calculate the portal inflow according to the association with weight, density and volume of the perfusate. A total of 10 rat livers underwent 6 h of HMP using histidine-tryptophan-ketoglutarate solution enriched with acridine orange (AO) and propidium iodide (PI). The perfusion status of HMP was assessed by comparison of AO+PI-positive cell count in core region (CR) and peripheral region (PR) of rat liver under fluorescence microscopy. The dynamics (inflow, pressure and intrahepatic resistance of perfusion) were assessed to identify whether this system met the demands for HMP of rat livers. Biochemical [alanine transaminase (ALT), lactate dehydrogenase (LDH) and endothelin levels] and histological parameters (sinusoidal dilatation, endothelial cell detachment and vacuolization) were measured to determine cellular damage associated with HMP. No significant difference was observed between the CR and PR according to the comparison of the AO+PI-positive cell count, which indicated that complete perfusion was achieved. Intrahepatic resistance significantly decreased during the initial 3 h of HMP (P<0.01), but remained stable during the final 3 h. ALT and LDH levels significantly increased over the 6 h HMP duration: ALT (0 h, 42.67 +/- 5.81 U/l; 3 h, 90.67 +/- 6.74 U/l; 6 h, 164.33 +/- 7.31 U/l; P<0.01) and LDH (0 h, 492.90 +/- 90.20 U/l; 3 h, 973.53 +/- 97.4; 6 h, 1,843.40 +/- 85.78 U/l; P<0.01) However, the levels of endothelin and oxygen consumption were constant throughout HMP. Furthermore, histological analysis indicated sinusoidal dilation was significantly increased in the post-HMP group compared with the pre-HMP group (P<0.01); however, no other significant differences were observed. Combined with the results of ATP test (640.64 +/- 29.46 nmol/l) and bile production (4.88 +/- 0.69 mu l/h/g of liver) at the end of HMP, the present results demonstrated minimal cellular injury associated with HMP while retaining the dependability and portability of the LifePort Kidney Transporter, which suggests the modified HMP system met the demands required and may be suitable for rat liver preservation.
引用
收藏
页码:1410 / 1416
页数:7
相关论文
共 50 条
  • [21] Evaluation of a novel system for hypothermic oxygenated pulsatile perfusion preservation
    Doorschodt, Benedict M.
    Schreinemachers, Marie-Claire J.M.
    Florquin, Sandrine
    Lai, Wei
    Sitzia, Mario
    Zernecke, Alma
    Tolba, Rene H.
    International Journal of Artificial Organs, 2009, 32 (10): : 728 - 738
  • [22] Evaluation of a novel system for hypothermic oxygenated pulsatile perfusion preservation
    Doorschodt, Benedict M.
    Schreinemachers, Marie-Claire J. M.
    Florquin, Sandrine
    Lai, Wei
    Sitzia, Mario
    Zernecke, Alma
    Tolba, Rene H.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (10): : 728 - 738
  • [23] Preservation of human pancreas with hypothermic machine perfusion
    Cantarovich, Diego
    Renaudin, Karine
    Branchereau, Julien
    TRANSPLANTATION, 2016, 100 (07) : S328 - S328
  • [24] Hypothermic machine perfusion in kidney transplantation
    De Deken, Julie
    Kocabayoglu, Peri
    Moers, Cyril
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2016, 21 (03) : 294 - 300
  • [25] PRESERVATION/REPERFUSION INJURY IS ATTENUATED BY HYPOTHERMIC MACHINE PERFUSION IN HUMAN LIVER TRANSPLANTATION
    Henry, Scot D.
    Chen, Sean W. C.
    Lee, H. Thomas
    Emond, Jean C.
    Guarrera, James V.
    LIVER TRANSPLANTATION, 2009, 15 (07) : S149 - S149
  • [26] Rat liver preservation by hypothermic oscillating liver perfusion compared to simple cold storage
    Dutkowski, P
    Schönfeld, S
    Odermatt, B
    Heinrich, T
    Junginger, T
    CRYOBIOLOGY, 1998, 36 (01) : 61 - 70
  • [27] Portable hypothermic oxygenated machine perfusion for organ preservation in liver transplantation (PILOT)
    Czigany, Zoltan
    Putri, Aghnia J.
    Michalski, Christoph W.
    Mehrabi, Arianeb
    HEPATOLOGY, 2024, 79 (06) : E165 - E166
  • [28] Hypothermic machine perfusion in liver transplantation
    Karangwa, S.
    Panayotova, G.
    Dutkowski, P.
    Porte, R. J.
    Guarrera, J., V
    Schlegel, A.
    INTERNATIONAL JOURNAL OF SURGERY, 2020, 82 : 44 - 51
  • [29] The Airdrive: a disposable hypothermic oxygenated machine perfusion system for the liver
    Dirkes, M. C.
    Post, I. C.
    van Gulik, T. M.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : S61 - S61
  • [30] Hypothermic machine perfusion in liver transplantation
    Schlegel, Andrea
    Kron, Philipp
    Dutkowski, Philipp
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2016, 21 (03) : 308 - 314