Exergy analysis on optimal desiccant solution flow rate in heat exchanger for air dehumidification using liquid desiccant

被引:8
|
作者
Guan, Bowen [1 ]
Liu, Xiaohua [1 ]
Zhang, Tao [1 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci & Technol, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Dehumidification; Liquid desiccant; Heat exchanger; Optimal solution flow rate; Exergy analysis; THERMODYNAMIC PROPERTIES; CONDITIONING SYSTEM; AQUEOUS-SOLUTIONS; PERFORMANCE; TEMPERATURE; ENTRANSY; LITHIUM; ENERGY; DRIVEN; LIBR;
D O I
10.1016/j.ijrefrig.2021.03.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat exchanger for air dehumidification using liquid desiccant is mainly composed of an air-solution heat exchanger (dehumidifier) and a solution-refrigerant heat exchanger, wherein there are three liquids, i.e., air, desiccant solution, and refrigerant. The same air dehumidification process can be achieved by different solution flow rates (m(s)). Limited studies have revealed which solution flow rate is optimal (m(s,opt)) for minimizing the exergy input of the heat exchanger (Ex(cooler)). Thus, the analytical solution for the effectiveness of the entire heat exchanger (epsilon) is theoretically deduced in this study, by the virtue of which, the m(s,opt) can be determined by solving partial derivative epsilon / partial derivative m(s) = 0. Results reveal that epsilon can be improved from 0.50 to 0.56 and Ex(cooler) can be saved by 17.9% in the given case, when the flow rate ratio of solution to air increases from 0.7 to the optimal value 1.5. Moreover, the air-solution-refrigerant flow rate matching plays an important role in the heat exchanger effectiveness. As a media fluid between the variable-temperature fluid (air) and the constant-temperature fluid (refrigerant), there is no solution flow rate to make the air-solution flow rate matching and solution-refrigerant flow rate matching simultaneously achieved. A compromised m(s,opt) should be pursued to balance the air-solution mismatching and the solution-refrigerant mismatching. It is anticipated that the findings of this research can be used for achieving an efficient air dehumidification process in the heat exchanger using liquid desiccant. (C) 2021 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:129 / 138
页数:10
相关论文
共 50 条
  • [31] Analysis on parameters of dehumidification tower in liquid desiccant dehumidification systems
    Tu, Min
    Tang, Guangfa
    Ren, Chengqin
    Zeng, Yang
    Cai, Dehong
    Huagong Xuebao/CIESC Journal, 2010, 61 (10): : 2546 - 2551
  • [32] Study of the Heat and Mass Transfer in a Dehumidification of liquid desiccant
    Salarian, Hesamoddin
    MECHANICAL AND AEROSPACE ENGINEERING, PTS 1-7, 2012, 110-116 : 120 - 126
  • [33] Performance analysis of liquid desiccant dehumidification systems
    Jain, Sanjeev
    Bansal, P. K.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (05): : 861 - 872
  • [34] Study on heat transfer and dehumidification performance of desiccant coated microchannel heat exchanger
    Wang, Cong
    Ji, Xu
    Yang, Bianfeng
    Zhang, Ren
    Yang, Delong
    APPLIED THERMAL ENGINEERING, 2021, 192
  • [35] Greenhouse dehumidification by zeolite-based desiccant coated heat exchanger
    Amani, Mohammad
    Bahrami, Majid
    APPLIED THERMAL ENGINEERING, 2021, 183 (183)
  • [36] A novel curdlan based desiccant coated heat exchanger for efficient dehumidification
    Lei, Xiaoping
    Ying, Wenjun
    Xue, Zhaoran
    Zhang, Hua
    Wang, Jiayun
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [37] Study on heat transfer and dehumidification performance of desiccant coated microchannel heat exchanger
    Wang, Cong
    Ji, Xu
    Yang, Bianfeng
    Zhang, Ren
    Yang, Delong
    Applied Thermal Engineering, 2021, 192
  • [38] Predictions of moisture removal rate and dehumidification effectiveness for structured liquid desiccant air dehumidifier
    Abdul-Wahab, SA
    Zurigat, YH
    Abu-Arabi, MK
    ENERGY, 2004, 29 (01) : 19 - 34
  • [39] ENTHALPY AND EXERGY ANALYSIS OF DOMESTIC DESICCANT AIR CONDITIONER WITH COOLING DEHUMIDIFICATION AND HEATING HUMIDIFICATION USING PROCESS SIMULATOR
    Hirano, Shun
    Hisazumi, Yoshinori
    Hori, Tsukasa
    Wakabayashi, Tsutomu
    Kishimoto, Akira
    Enomoto, Hakaru
    Ueda, Kentaro
    PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 1, 2012, : 465 - +
  • [40] Experimental study on dehumidification/regeneration of liquid desiccant: LiBr solution
    Bouzenada, S.
    Kaabi, A. N.
    Fraikin, L.
    Leonard, A.
    5TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT-2014), THE 4TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT-2014), 2014, 32 : 673 - 680