Use of protein G microcolumns in chromatographic immunoassays: A comparison of competitive binding formats

被引:7
|
作者
Pfaunmiller, Erika L. [1 ]
Anguizola, Jeanethe A. [1 ]
Milanuk, Mitchell L. [1 ]
Carter, NaTasha [1 ]
Hage, David S. [1 ]
机构
[1] Univ Nebraska, Dept Chem, 704 Hamilton Hall, Lincoln, NE 68588 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Chromatographic immunoassay; Affinity microcolumn; Protein G; Competitive binding immunoassay; Human serum albumin; FLOW-INJECTION IMMUNOASSAY; SPLIT-PEAK CHROMATOGRAPHY; FREE DRUG FRACTIONS; CAPILLARY; MODEL; IMMOBILIZATION; ASSAYS;
D O I
10.1016/j.jchromb.2015.12.055
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Affinity microcolumns containing protein G were used as general platforms for creating chromatographic based competitive binding immunoassays. Human serum albumin (HSA) was used as a model target for this work and HSA tagged with a near infrared fluorescent dye was utilized as the label. The protein G microcolumns were evaluated for use in several assay formats, including both solution-based and column-based competitive binding immunoassays and simultaneous or sequential injection formats. All of these methods were characterized by using the same amounts of labeled HSA and anti-HSA antibodies per sample, as chosen for the analysis of a protein target in the low-to-mid ng/mL range. The results were used to compare these formats in terms of their response, precision, limit of detection, and analysis time. All these methods gave detection limits in the range of 8-19 ng/mL and precisions ranging from +/- 5% to +/- 10% when using an injection flow rate of 0.10 mL/min. The column-based sequential injection immunoassay provided the best limit of detection and the greatest change in response at low target concentrations, while the solution-based simultaneous injection method had the broadest linear and dynamic ranges. These results provided valuable guidelines that can be employed to develop and extend the use of protein G microcolumns and these competitive binding formats to other protein biomarkers or biological agents of clinical or pharmaceutical interest. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:91 / 100
页数:10
相关论文
共 50 条
  • [41] The use of fluorescent ligands to explore the ligand binding site of G protein coupled receptors
    Tota, MR
    Fong, TM
    Strader, CD
    STRUCTURE AND FUNCTION OF 7TM RECEPTORS, 1996, 39 : 162 - 168
  • [42] CRITICAL COMPARISON OF 4 COMPETITIVE PROTEIN-BINDING METHODS FOR DETERMINING THYROXINE (T4) IN SERUM
    FRINGS, CS
    HOCHHOLZER, JM
    CLINICAL CHEMISTRY, 1974, 20 (07) : 864 - 864
  • [43] COMPARISON OF COMPETITIVE PROTEIN-BINDING ASSAY AND RADIOIMMUNOASSAY FOR PLASMA PROGESTERONE DURING NORMAL MENSTRUAL-CYCLE
    MORGAN, CA
    COOKE, ID
    JOURNAL OF ENDOCRINOLOGY, 1972, 54 (03) : 445 - &
  • [44] Development of a microplate-based, electrophoretic fluorescent protein kinase a assay: Comparison with filter-binding and fluorescence polarization assay formats
    Miick, S
    Jalali, S
    Dwyer, B
    Havens, J
    Thomas, D
    Jimenez, M
    Simpson, M
    Zile, B
    Huss, K
    Campbell, R
    JOURNAL OF BIOMOLECULAR SCREENING, 2005, 10 (04) : 329 - 338
  • [45] PRINCIPLES OF A COMPETITIVE-BINDING ASSAY FOR THE STUDY OF THE INTERACTIONS OF POORLY WATER-SOLUBLE LIGANDS WITH THEIR SOLUBLE BINDING PARTNERS - APPLICATION TO BILIRUBIN WITH THE USE OF SEPHADEX G-10 AS A COMPETITIVE ADSORBENT
    MEUWISSEN, JATP
    KINNAERT, M
    MICHIELS, G
    HEIRWEGH, KPM
    BIOCHEMICAL JOURNAL, 1988, 249 (01) : 263 - 270
  • [46] SEPARATION OF FREE AND PROTEIN-BOUND STEROIDS WITH AMBERLITE - USE IN DETERMINATION OF TESTOSTERONE IN PLASMA BY MEANS OF COMPETITIVE PROTEIN-BINDING METHOD
    WIEDEMANN, M
    WIRTZ, A
    RAITH, L
    KARL, HJ
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1972, 261 (4-5): : 382 - +
  • [47] Comparison of [Dmt1]DALDA and DAMGO in binding and G protein activation at μ, δ, and κ opioid receptors
    Zhao, GM
    Qian, XX
    Schiller, PW
    Szeto, HH
    JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 2003, 307 (03): : 947 - 954
  • [48] Bioconjugates of luminescent CdSe-ZnS quantum dots with an engineered two-domain protein G for use in fluoro-immunoassays
    Tran, PT
    Goldman, ER
    Mattoussi, H
    Anderson, GP
    Mauro, JM
    NANOPARTICLES AND NANOSTRUCTURED SURFACES: NOVEL REPORTERS WITH BIOLOGICAL APPLICATIONS, 2001, 4258 : 1 - 7
  • [49] Comparison of retinol binding protein 1 with cone specific G-protein as putative effector molecules in cryptochrome signalling
    Yee, Chad
    Bartoelke, Rabea
    Goertemaker, Katharina
    Schmidt, Jessica
    Leberecht, Bo
    Mouritsen, Henrik
    Koch, Karl-Wilhelm
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [50] Use of fluorescence polarization detection for the measurement of FluoPeptide™ binding to G protein-coupled receptors
    Gagne, A
    Banks, P
    Hurt, SD
    JOURNAL OF RECEPTOR AND SIGNAL TRANSDUCTION RESEARCH, 2002, 22 (1-4): : 333 - 343