Semi-active tuned mass damper control strategy for wind-excited structures

被引:44
|
作者
Ricciardelli, F
Occhiuzzi, A
Clemente, P
机构
[1] Univ Naples Federico II, Dipartimento Anat & Progettazione Strutturale, I-80125 Naples, Italy
[2] Univ Reggio Calabria, Dipartimento Meccan & Mat, Calabria, Italy
[3] ENEA, Ctr Ric Casaccia, Rome, Italy
关键词
tuned mass damper (TMD); semi-active control; wind-excited structures;
D O I
10.1016/S0167-6105(00)00024-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Uncertainties in the main structure dynamic properties as well as those in the characteristics of the excitation may cause a deterioration of the performance of Tuned Mass Dampers. This may happen because the choice of tuning and damping ratio of the auxiliary system, based on the expected values of the dynamic properties of the main structure and on a simple excitation pattern, may prove away from the optimum. An empirical algorithm is presented in this paper which allows the performance of the TMD to be optimised, based on the measured response. The algorithm relies on two assumptions: the smoothness of the spectrum of excitation and the availability of an estimate of the dynamic properties of the main structure. As an example the algorithm is applied to a 64-story building subjected to turbulence buffeting. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:57 / 74
页数:18
相关论文
共 50 条
  • [21] Study on vibration control of rotor with semi-active cage-type tuned mass damper
    Huang, Xiu-Jin
    He, Li-Dong
    Huang, Wen-Chao
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2015, 30 (12): : 2882 - 2887
  • [22] Stochastic optimal control of wind-excited tall buildings using semi-active MR-TLCDs
    Ni, YQ
    Ying, ZG
    Wang, JY
    Ko, JM
    Spencer, BF
    PROBABILISTIC ENGINEERING MECHANICS, 2004, 19 (03) : 269 - 277
  • [23] Nonlinear structural control using integrated DDA/ISMP and semi-active tuned mass damper
    Karami, Kaveh
    Manie, Salar
    Ghafouri, Khatib
    Nagarajaiah, Satish
    ENGINEERING STRUCTURES, 2019, 181 : 589 - 604
  • [24] EFFECT OF SEMI-ACTIVE TUNED MASS DAMPER TO CONTROL VIBRATIONS OF A THREE-STOREY BUILDING
    Pastia, Cristian
    Luca, Septimiu-George
    Toma, Ionut
    GEOCONFERENCE ON SCIENCE AND TECHNOLOGIES IN GEOLOGY, EXPLORATION AND MINING, VOL I, 2014, : 443 - 450
  • [25] Control of nonlinear offshore platforms using semi-active tuned mass damper inerter under combined wave and wind loads
    Gavgani, Seyyed Ali Mousavi
    Lavassani, Seyed Hossein Hosseini
    Bekdas, Gebrail
    APPLIED OCEAN RESEARCH, 2025, 154
  • [26] Semi-active tuned mass dampers with phase control
    Chung, Lap-Loi
    Lai, Yong-An
    Yang, Chuang-Sheng Walter
    Lien, Kuan-Hua
    Wu, Lai-Yun
    JOURNAL OF SOUND AND VIBRATION, 2013, 332 (15) : 3610 - 3625
  • [27] Optimal design formulas for viscous tuned mass dampers in wind-excited structures
    Chung, Lap-Loi
    Wu, Lai-Yun
    Yang, Chuang-Sheng Walter
    Lien, Kuan-Hua
    Lin, Mei-Chun
    Huang, Hsu-Hui
    STRUCTURAL CONTROL & HEALTH MONITORING, 2013, 20 (03): : 320 - 336
  • [28] Seismic performance improvement of base-isolated structures using a semi-active tuned mass damper
    Wang, Liangkun
    Nagarajaiah, Satish
    Shi, Weixing
    Zhou, Ying
    ENGINEERING STRUCTURES, 2022, 271
  • [29] Passive and semi-active control of an offshore floating wind turbine using a tuned liquid column damper
    Coudurier, Christophe
    Lepreux, Olivier
    Petit, Nicolas
    IFAC PAPERSONLINE, 2015, 48 (16): : 241 - 247