Development of sensitive non-enzymatic glucose sensor using complex nanostructures of cobalt oxide

被引:51
|
作者
Soomro, Razium Ali [1 ,2 ]
Nafady, Aynam [3 ,4 ]
Ibupoto, Zafar Hussain [5 ]
Sirajuddin [1 ]
Sherazi, Syed Tufail Hussain [1 ]
Willander, Magnus [6 ]
Abro, Muhammad Ishaq [7 ]
机构
[1] Univ Sindh, Natl Ctr Excellence Analyt Chem, Jamshoro 76080, Pakistan
[2] Univ Bristol, Sch Phys, Interface Anal Ctr, Bristol BS8 1TL, Avon, England
[3] King Saud Univ, Dept Chem, Coll Sci, Riyadh 11451, Saudi Arabia
[4] Sohag Univ, Dept Chem, Fac Sci, Sohag 82524, Egypt
[5] Univ Sindh, Dr MA Kazi Inst Chem, Jamshoro 76080, Pakistan
[6] Linkoping Univ, Dept Sci & Technol, SE-60174 Norrkoping, Sweden
[7] Mehran Univ Engn & Technol, Dept Met & Mat Engn, Jamshoro 76080, Pakistan
关键词
Cobalt oxide nanostructures; Non-enzymatic glucose sensor; Cyclic voltammetry; GLASSY-CARBON ELECTRODE; CATALYTIC-ACTIVITY; NANOPARTICLES; ION; NANOTUBES; OXYHYDROXIDE; NANOFIBERS; HYDROXIDES; SOLVENT; POLYMER;
D O I
10.1016/j.mssp.2015.02.055
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The study reports the synthesis of cobalt oxide (Co3O4) nanostructures and their application in enzyme free electrochemical sensing of glucose. The synthesized nanostructures were elaborately characterized via number of analytical techniques including scanning electron microscopy, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR). The as-synthesized nanostructures of Co3O4 were found to exhibited nanodisc like morphology with the size dimension in range of 300-500 nm. The obtained morphological features were evaluated for their electrochemical potential towards oxidation of glucose which enabled development of sensitive (27.33 mu A mM(-1) cm(-2)), and stable enzyme free glucose sensor. In addition, the developed sensor showed excellent linearity (r(2)=0.9995), wide detection range (0.5-5.0 mM), lower detection limit (0.8 mu M) and extreme selectivity towards glucose in the presence of common interferents like dopamine (DP), ascorbic acid (AA) and uric acid (UA). The successfully application of developed sensor for real blood glucose analysis further reflects its capability for routine glucose measurement. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:373 / 381
页数:9
相关论文
共 50 条
  • [31] Graphene oxide/silver nanocomposite based non-enzymatic glucose sensor
    Singhal A.
    Anand V.K.
    Virdi G.S.
    Singhal, Anuj, 2018, American Scientific Publishers (12): : 397 - 400
  • [32] Tantalum oxide honeycomb architectures for the development of a non-enzymatic glucose sensor with wide detection range
    Suneesh, P. V.
    Chandhini, K.
    Ramachandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    BIOSENSORS & BIOELECTRONICS, 2013, 50 : 472 - 477
  • [33] A non-enzymatic electrochemical hydrogen peroxide sensor based on copper oxide nanostructures
    Mihailova, Irena
    Gerbreders, Vjaceslavs
    Krasovska, Marina
    Sledevskis, Eriks
    Mizers, Valdis
    Bulanovs, Andrejs
    Ogurcovs, Andrejs
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2022, 13 : 424 - 436
  • [34] Non-enzymatic salivary glucose detection using porous CuO nanostructures
    Chakraborty, Pinak
    Dhar, Saurab
    Deka, Nitumoni
    Debnath, Kamalesh
    Mondal, Suvra Prakash
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 302
  • [35] Cobalt oxide acicular nanorods with high sensitivity for the non-enzymatic detection of glucose
    Kung, Chung-Wei
    Lin, Chia-Yu
    Lai, Yi-Hsuan
    Vittal, R.
    Ho, Kuo-Chuan
    BIOSENSORS & BIOELECTRONICS, 2011, 27 (01): : 125 - 131
  • [36] High sensitive polyaniline nanosheets (PANINS) @rGO as non-enzymatic glucose sensor
    Saraswathi Kailasa
    R. Kiran Kumar Reddy
    M. Sai Bhargava Reddy
    B. Geeta Rani
    Hussen Maseed
    R. Sathyavathi
    K. Venkateswara Rao
    Journal of Materials Science: Materials in Electronics, 2020, 31 : 2926 - 2937
  • [37] High sensitive polyaniline nanosheets (PANINS) @rGO as non-enzymatic glucose sensor
    Kailasa, Saraswathi
    Reddy, R. Kiran Kumar
    Reddy, M. Sai Bhargava
    Rani, B. Geeta
    Maseed, Hussen
    Sathyavathi, R.
    Rao, K. Venkateswara
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2020, 31 (04) : 2926 - 2937
  • [38] A highly sensitive non-enzymatic glucose electrochemical sensor based on NiO nanohives
    Thi Oanh Vu
    Thi Xuan Chu
    Duc Hoa Nguyen
    ADVANCES IN NATURAL SCIENCES-NANOSCIENCE AND NANOTECHNOLOGY, 2021, 12 (04)
  • [39] New ZnO nanostructures as non-enzymatic glucose biosensors
    Tarlani, Aliakbar
    Fallah, Mahtab
    Lotfi, Behzad
    Khazraei, Avideh
    Golsanamlou, Sommayeh
    Muzart, Jacques
    Mirza-Aghayan, Maryam
    BIOSENSORS & BIOELECTRONICS, 2015, 67 : 601 - 607
  • [40] Facile synthesis of CuO nanostructures for non-enzymatic glucose sensor by modified SILAR method
    Patil, A. S.
    Patil, R. T.
    Lohar, G. M.
    Fulari, Vijay J.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2021, 127 (02):