Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences

被引:32
|
作者
Kunz, RP
Oellig, F
Krummenauer, F
Oberholzer, K
Romaneehsen, B
Vomweg, TW
Horstick, G
Hayes, C
Thelen, M
Kreitner, KF
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Biometry Epidemiol & Informat, D-55131 Mainz, Germany
[3] Univ Mainz, Dept Internal Med & Cardiol, D-55131 Mainz, Germany
[4] Siemens AG, Erlangen, Germany
关键词
magnetic resonance imaging; heart; steady-state imaging; real-time imaging; cardiac ventricular function;
D O I
10.1002/jmri.20230
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging. Materials and Methods: End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.5 msec, TA 18 beats per slice; protocol B) segmented, shared phases: tRes 34.1 msec, TA 10 beats per slice; and protocol Q real-time, shared phases, parallel acquisition technique: tRes 47.3 msec, TA 24 beats for 12 slices covering the entire left ventricle. Results: Phase sharing leads to a significant decrease in EDV, stroke volume (SV), and ejection fraction (EF) (median difference -7.0 mL [*], -9.6 mL, and -3.4%, respectively, for protocol B; -15.3 mL, -13.3 mL, and -2.4% for protocol C; P = 0.002, *P = 0.021). The observed median difference of real-time EDV and SV estimates is of clinical relevance. Real-time cine MR imaging shows a greater variability of EDV and SV. No relevant differences in ESV were observed. Conclusion: The true cine frame duration of both shared phases sequence protocols exceeds the period of isovolumetric contraction (IVCT) of the left ventricle resulting in a systematic and significant underestimation of EDV and consequently SV and EF. SSFP sequence protocol parameters, particularly tRes and use of view sharing techniques, should therefore be known at follow-up examinations in order to be able to assess LV remodeling in patients with heart failure.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 50 条
  • [41] High-resolution steady-state free precession coronary magnetic resonance angiography within a breath-hold: Parallel imaging with extended cardiac data acquisition
    Park, J
    Larson, AC
    Zhang, Q
    Simonetti, O
    Li, DB
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) : 1100 - 1106
  • [42] Coronary artery imaging using three-dimensional breath-hold steady-state free precession with two-dimensional iterative partial Fourier reconstruction
    Singh, RK
    Deshpande, VS
    Haacke, EM
    Shea, SM
    Xu, YB
    McCarthy, RM
    Carr, J
    Li, DB
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (05) : 645 - 649
  • [43] Assessment of Motility Function of the Small Bowel with Cine-MR Imaging Using Balanced Steady-State Free Precession Imaging (FIESTA Sequence): Preliminary Study in Healthy Volunteers
    Wakamiya, M.
    Furukawa, A.
    Kanasaki, S.
    Kono, N.
    Maeda, K.
    Sasaki, T.
    Murata, K.
    Sakamoto, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [44] Accurate quantification of right ventricular mass at MR imaging by using cine true fast imaging with steady-state precession:: Study in dogs
    Shors, SM
    Fung, CW
    François, CJ
    Finn, JP
    Fieno, DS
    RADIOLOGY, 2004, 230 (02) : 383 - 388
  • [45] T2-WEIGHTED BREATH-HOLD MR-IMAGING OF THE LIVER AT 1.5-T - RESULTS WITH A 3-DIMENSIONAL STEADY-STATE FREE PRECESSION SEQUENCE IN 87 PATIENTS
    TAUPITZ, M
    SPEIDEL, A
    HAMM, B
    DEIMLING, M
    REICHEL, M
    BOCK, A
    WOLF, KJ
    RADIOLOGY, 1995, 194 (02) : 439 - 446
  • [46] Interleaved, undersampled radial multiple-acquisition steady-state free precession for improved left atrial cine imaging
    Robb, Jaime S.
    Hu, Chenxi
    Peters, Dana C.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1721 - 1729
  • [47] Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
    Alfakih, K
    Plein, S
    Thiele, H
    Jones, T
    Ridgway, JP
    Sivananthan, MU
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) : 323 - 329
  • [48] Breath-hold 3D steady-state free precession coronary MRA compared with conventional x-ray coronary angiography
    Cheng, LQ
    Gao, YG
    Guaricci, AI
    Mulukutla, S
    Sun, W
    Sheng, FG
    Foo, TK
    Prince, MR
    Wang, Y
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) : 669 - 673
  • [49] Steady-state free precession MRA of the renal arteries: Breath-hold and navigator-gated techniques vs. CE-MRA
    Maki, Jeffrey H.
    Wilson, Gregory J.
    Eubank, William B.
    Glickerman, David J.
    Pipavath, Sudhakar
    Hoogeveen, Romhild M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 966 - 973
  • [50] Cardiac CINE imaging with IDEAL water-fat separation and steady-state free precession
    Reeder, SB
    Markl, M
    Yu, HZ
    Hellinger, JC
    Herfkens, RJ
    Pelc, NJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (01) : 44 - 52