This paper introduces a novel pole consisting of spun-cast concrete inside glass-fiber-reinforced polymer (GFRP) tubes (SCFTs). The GFRP tube is intended to replace all or part of the steel reinforcement. It confines and protects the thin concrete wall and any steel reinforcement used. This novel concept emerged after studying two types of poles, namely a hollow GFRP tube that failed prematurely by local buckling and a completely filled GFRP tube (CFFT) that was higher in strength but much heavier than the hollow tube. The feasibility of fabrication in a conventional spin-casting facility is demonstrated. Push-off tests on segments cut from an SCFT pole were tested to examine the bond strength. Flexural testing showed that the strength of a 13-in.-diameter (330 mm) SCFT pole with a 0.15-in.-thick (5.3 mm) GFRP tube and a 2.4 in. (60 mm) concrete wall is equivalent to that of a conventional pole of the same size, reinforced with twelve no. 6 (19M) reinforcing bars or prestressed with twelve 1/2-in.-diameter (13 mm) 7-wire strands. SCFT poles also behave fairly elastically. Practical considerations that need to be addressed to encourage wide acceptance of this concept are identified.
引用
收藏
页码:100 / 113
页数:14
相关论文
共 50 条
  • [41] Development of a High-Speed Terahertz Wave Inspection System Based on the Galvano Scanner to Inspect Defects in Glass-Fiber-Reinforced Polymer
    Kim, Heon-Su
    Park, Dong-Woon
    Kim, Sang-Il
    Kim, Hak-Sung
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2021, 41 (05) : 283 - 288
  • [42] Strengthening reinforced concrete beams using prestressed glass fiber-reinforced polymer—Part I: Experimental study
    Huang Yue-lin
    Wu Jong-hwei
    Yen Tsong
    Hung Chien-hsing
    Lin Yiching
    Journal of Zhejiang University-SCIENCE A, 2005, 6 (3): : 166 - 174
  • [43] Strengthening reinforced concrete beams using prestressed glass fiber-reinforced polymer - Part II: Analytical study
    Huang Y.-L.
    Hung C.-H.
    Yen T.
    Wu J.-H.
    Lin Y.-C.
    Journal of Zhejiang University-SCIENCE A, 2005, 6 (8): : 844 - 852
  • [44] Mechanical performance of glass fiber-reinforced polymer tubes filled with steel-reinforced high-strength concrete subjected to eccentric compression
    Zhou, Le
    Wang, Lianguang
    Zong, Liang
    Shi, Gang
    Bai, Yunhao
    Nie, Xiaomei
    ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (03) : 374 - 393
  • [45] Strengthening reinforced concrete beams using prestressed glass fiber-reinforced polymer-Part II:Analytical study
    HUNG Chien-hsing
    YEN Tsong
    WU Jong-hwei
    Journal of Zhejiang University Science A(Science in Engineering), 2005, (08) : 844 - 852
  • [46] Strengthening reinforced concrete beams using prestressed glass fiber-reinforced polymer-Part I: Experimental study
    WU Jong-hwei
    YEN Tsong
    HUNG Chien-hsing
    LIN Yiching
    Journal of Zhejiang University Science A(Science in Engineering), 2005, (03) : 13 - 21
  • [47] Rectangular filament-wound glass fiber reinforced polymer tubes filled with concrete under flexural and axial loading: Experimental investigation
    Fam, A
    Schnerch, D
    Rizkalla, S
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (01) : 25 - 33
  • [48] Rectangular filament-wound glass fiber reinforced polymer tubes filled with concrete under flexural and axial loading: Analytical modeling
    Fam, A
    Manda, S
    Rizkalla, S
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (01) : 34 - 43
  • [49] A new studded precast concrete sandwich wall with embedded glass-fiber-reinforced polymer channel sections: Part 2, finite element analysis and parametric studies
    Jawdhari, Akram
    Fam, Amir
    PCI JOURNAL, 2020, 65 (04): : 51 - 70
  • [50] Weight minimum design of concrete beam strengthened with glass fiber reinforced polymer bar using genetic algorithm
    Rahman, Md. Moshiur
    Jumaat, Mohd Zamin
    Islam, A. B. M. Saiful
    COMPUTERS AND CONCRETE, 2017, 19 (02): : 127 - 131