Laboratory and field validations of a solid-phase microextraction device for the determination of ethylene oxide

被引:14
|
作者
Tsai, SW
Tsai, ST
Wang, VS
Lai, JS
机构
[1] China Med Univ, Dept Occupat Safety & Hlth, Taichung, Taiwan
[2] China Med Univ, Inst Environm Med, Taichung, Taiwan
关键词
sample preparation; air analysis; environmental analysis; instrumentation; ethylene oxide; hydrogen bromide;
D O I
10.1016/j.chroma.2003.10.088
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Laboratory and field evaluations were performed to validate a solid-phase microextraction (SPME) device that was used as a diffusive sampler. Hydrogen bromide (HBr) was loaded onto the carboxen-polydimethylsiloxane (CAR-PDMS) fiber for the determination of ethylene oxide (EtO) with on-fiber derivatization. For laboratory evaluations, known concentrations of ethylene oxide around the threshold limit values (TLV)/time-weighted average and specific relative humidities (RHs) were generated by syringe pumps in a dynamic generation system. The SPME diffusive samplers and the commercially available 3M 3551 passive monitors were placed side-by-side in an exposure chamber which was designed to allow measurement of face velocities, temperatures, exposing vapor concentrations, and RHs. Field validations with both SPME diffusive sampler and 3M 3551 passive monitors were also performed. The correlations between the results from both SPME device and 3M 3551 passive monitor were found to be linear (r > 0.9699) and consistent (slope congruent to 1.12 +/- 0.07). However, the variations of diffusion coefficients at different temperatures needs to be considered and the adjustment of sampling constant was a must when sampling at temperatures different from 25degreesC. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 50 条
  • [41] DETERMINATION OF FATTY-ACIDS USING SOLID-PHASE MICROEXTRACTION
    PAN, L
    ADAMS, M
    PAWLISZYN, J
    ANALYTICAL CHEMISTRY, 1995, 67 (23) : 4396 - 4403
  • [42] Determination of acetone in seawater using derivatization solid-phase microextraction
    Edward D. Hudson
    Kadek Okuda
    Parisa A. Ariya
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1275 - 1282
  • [43] Determination of MTBE in a recreational harbor using solid-phase microextraction
    Zuccarello, JL
    Ganske, JA
    Green, DB
    CHEMOSPHERE, 2003, 51 (08) : 805 - 810
  • [44] Preconcentration by solid-phase microextraction
    Zaitsev, V. N.
    Zui, M. F.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (08) : 715 - 727
  • [45] Solid-phase microextraction determination of alcohol using pencil lead
    Tong, Z
    Guanghan, L
    Xin, Y
    ANALYTICAL LETTERS, 2001, 34 (04) : 627 - 634
  • [46] Determination of organophosphorus pesticides in honeybees after solid-phase microextraction
    Fernández, M
    Padrón, C
    Marconi, L
    Ghini, S
    Colombo, R
    Sabatini, AG
    Girotti, S
    JOURNAL OF CHROMATOGRAPHY A, 2001, 922 (1-2) : 257 - 265
  • [47] Advances in Solid-Phase Microextraction
    Naccarato, Attilio
    Tagarelli, Antonio
    SEPARATIONS, 2020, 7 (02)
  • [48] Determination of chloroethers in aqueous samples using solid-phase microextraction
    Wennrich, L
    Engewald, W
    Popp, P
    ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 1997, 25 (06): : 329 - 334
  • [50] Theory of solid-phase microextraction
    Pawliszyn, J
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2000, 38 (07) : 270 - 278