Descemet's stripping with automated endothelial keratoplasty (DSAEK)

被引:27
|
作者
Cursiefen, C. [1 ]
Kruse, F. E. [1 ]
机构
[1] Univ Erlangen Nurnberg, Augenklin Poliklin, D-91054 Erlangen, Germany
来源
OPHTHALMOLOGE | 2008年 / 105卷 / 02期
关键词
corneal transplantation; posterior lamellar keratoplasty; microkeratome; descement's stripping; DSAEK;
D O I
10.1007/s00347-007-1680-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background. Although penetrating keratoplasty remains the gold standard for surgically treating corneal endothelial pathologies, tremendous progress has been made in recent years to improve the technology of (posterior) lamellar keratoplasty. Methods. Literature review from PubMed and own data. Results. Posterior lamellar keratoplasty using a microkeratome (Descemet's stripping with automated endothelial keratoplasty, or DSAEK) is a reliable surgical technique for Fuchs' endothelial dystrophy and pseudophakic bullous keratopathy. Visual rehabilitation is faster with lamellar keratoplasty than penetrating keratoplasty. Conclusion. Posterior lamellar keratoplasty techniques such as DSAEK will become an important surgical treatment option for corneal endothelial pathologies.
引用
收藏
页码:183 / +
页数:9
相关论文
共 50 条
  • [31] Outcomes of rebubbling for graft detachment after Descemet's stripping endothelial keratoplasty or Descemet's stripping automated endothelial keratoplasty
    Bhalerao, Sushank A.
    Mohamed, Ashik
    Vaddavalli, Pravin K.
    Murthy, Somasheila, I
    Reddy, Jagadesh C.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (01) : 48 - 53
  • [32] Will Descemet's stripping with automated endothelial keratoplasty (DSAEK) lower the rates of allograft rejection in corneal transplants for endothelial failure?
    Prakash, Gaurav
    Jhanji, Vishat
    Titiyal, Jeewan Singh
    MEDICAL HYPOTHESES, 2007, 69 (05) : 1117 - 1119
  • [33] Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Automated Endothelial Keratoplasty
    Tourtas, Theofilos
    Laaser, Kathrin
    Bachmann, Bjoern O.
    Cursiefen, Claus
    Kruse, Friedrich E.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (06) : 1082 - 1090
  • [34] Impairment of Visual Acuity Due to Permanent Descemet Folds Following Descemet Stripping and Automated Endothelial Keratoplasty (DSAEK)
    Mueller, C.
    Sekundo, W.
    Schulze, A.
    Hoffmann, E. M.
    Pfeiffer, N.
    Vetter, J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [35] Effect of donor graft characteristics on clinical outcomes in Descemet stripping automated endothelial keratoplasty (DSAEK)
    Yin, G. Ho Wang
    Sampo, M.
    Soare, S.
    Hoffart, L.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2017, 40 (01): : 36 - 43
  • [36] Topographic characteristics after Descemet's membrane endothelial keratoplasty and Descemet's stripping automated endothelial keratoplasty
    Hayashi, Takahiko
    Yamaguchi, Takefumi
    Yuda, Kentaro
    Kato, Naoko
    Satake, Yoshiyuki
    Shimazaki, Jun
    PLOS ONE, 2017, 12 (11):
  • [37] In vivo confocal microscopy of corneal wound healing after Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK)
    Hernandez-Quintela, Everardo
    Ortiz Valencia, Claudia
    De Wit, Guillermo
    Ramirez Fernandez, Manuel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [38] Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty
    Woo, Jyh-Haur
    Ang, Marcus
    Htoon, Hla Myint
    Tan, Donald
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 207 : 288 - 303
  • [39] Influence of donor lamella thickness on visual acuity after Descemet's stripping automated endothelial keratoplasty (DSAEK)
    Maier, A. -K. B.
    Gundlach, E.
    Klamann, M. K. J.
    Gonnermann, J.
    Bertelmann, E.
    Joussen, A. M.
    Torun, N.
    Rieck, P. W.
    OPHTHALMOLOGE, 2014, 111 (02): : 128 - +
  • [40] Evaluation of Corneal Wound Healing and Ocular Optics After Descemet's Stripping With Automated Endothelial Keratoplasty (DSAEK)
    Miller, B. E.
    Pantanelli, S.
    Sabesan, R.
    DeMagistris, M.
    Cai, X.
    Huxlin, K.
    Yoon, G.
    Hindman, H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)