Simulation and experimental verification of ambient neutron doses in a pencil beam scanning proton therapy room as a function of treatment plan parameters

被引:7
|
作者
Van Hoey, Olivier [1 ]
Stolarczyk, Liliana [2 ,3 ,4 ]
Lillhoek, Jan [5 ]
Eliasson, Linda [6 ]
Mojzeszek, Natalia [3 ]
Liszka, Malgorzata [3 ,4 ]
Alkhiat, Ali [4 ,7 ]
Mares, Vladimir [8 ]
Trompier, Francois [9 ]
Trinkl, Sebastian [8 ,10 ]
Martinez-Rovira, Immaculada [11 ]
Romero-Exposito, Maite [11 ]
Domingo, Carles [11 ]
Ploc, Ondrej [12 ]
Harrison, Roger [13 ]
Olko, Pawel [3 ]
机构
[1] Belgian Nucl Res Ctr SCK CEN, Inst Environm, Hlth & Safety EHS, Mol, Belgium
[2] Aarhus Univ Hosp AUH, Danish Ctr Particle Therapy, Aarhus, Denmark
[3] Inst Nucl Phys, Polish Acad Sci, IFJ PAN, Krakow, Poland
[4] Skandion Clin, Uppsala, Sweden
[5] Swedish Radiat Safety Author, Solna, Sweden
[6] Royal Inst Technol KTH, Dept Phys, Stockholm, Sweden
[7] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Stockholm, Sweden
[8] Helmholtz Zentrum Munchen, Inst Radiat Med, Neuherberg, Germany
[9] Inst Radioprotect & Surete Nucl IRSN, PSE Sante, Fontenay aux roses, France
[10] Fed Off Radiat Protect, Neuherberg, Germany
[11] Univ Autonoma Barcelona, Dept Fis, Bellaterra, Spain
[12] Czech Acad Sci CAS, Dept Radiat Dosimetry, Nucl Phys Inst, Prague, Czech Republic
[13] Univ Newcastle Tyne, Fac Med Sci, Newcastle Upon Tyne, England
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
关键词
Proton therapy; Pencil beam scanned proton therapy; Neutron doses; Monte Carlo simulations; Out-of-field neutron doses in radiation therapy; Neutron measurements; FIELD; SPECTROMETRY; RADIATION; DOSIMETRY; COUNTERS;
D O I
10.3389/fonc.2022.903537
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Out-of-field patient doses in proton therapy are dominated by neutrons. Currently, they are not taken into account by treatment planning systems. There is an increasing need to include out-of-field doses in the dose calculation, especially when treating children, pregnant patients, and patients with implants. In response to this demand, this work presents the first steps towards a tool for the prediction of out-of-field neutron doses in pencil beam scanning proton therapy facilities. As a first step, a general Monte Carlo radiation transport model for simulation of out-of-field neutron doses was set up and successfully verified by comparison of simulated and measured ambient neutron dose equivalent and neutron fluence energy spectra around a solid water phantom irradiated with a variation of different treatment plan parameters. Simulations with the verified model enabled a detailed study of the variation of the neutron ambient dose equivalent with field size, range, modulation width, use of a range shifter, and position inside the treatment room. For future work, it is planned to use this verified model to simulate out-of-field neutron doses inside the phantom and to verify the simulation results by comparison with previous in-phantom measurement campaigns. Eventually, these verified simulations will be used to build a library and a corresponding tool to allow assessment of out-of-field neutron doses at pencil beam scanning proton therapy facilities.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Application of Monte Carlo Simulation for Treatment Planning System Commissioning and Dose Calculation for a Pencil Beam Scanning Proton Therapy System
    Hu, H.
    Liu, H.
    Jia, Y.
    Zheng, Y.
    Ding, S.
    Wang, B.
    Li, Y.
    Huang, X.
    Li, Z.
    MEDICAL PHYSICS, 2022, 49 (06) : E860 - E860
  • [42] An Evaluation and Quantification of Secondary Neutron Radiation Dose Due to Double Scatter and Pencil Beam Scanning Proton Therapy
    Glick, A.
    Diffenderfer, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3497 - 3497
  • [43] Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Rana, Suresh
    Gutierrez, Alonso N.
    Hill, Patrick M.
    MEDICAL PHYSICS, 2021, 48 (06) : 3172 - 3185
  • [44] Experimental Validation and Calculation Benchmark for a Commercial Monte Carlo Pencil Beam Scanning Proton Therapy Treatment Planning System in Water
    Lin, L.
    Huang, S.
    Kang, M.
    Ainsley, C.
    Hiltunen, P.
    Vanderstraeten, R.
    Lindberg, J.
    Siljamaki, S.
    Wareing, T.
    Davis, I.
    Barnett, A.
    McGhee, J.
    Solberg, T.
    McDonough, J.
    Simone, C., II
    MEDICAL PHYSICS, 2016, 43 (06) : 3497 - 3497
  • [45] Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy
    Smith, Blake R.
    Pankuch, Mark
    Hyer, Daniel E.
    Culberson, Wesley S.
    MEDICAL PHYSICS, 2020, 47 (10) : 5343 - 5356
  • [46] Experimental validation of a 4D dose calculation routine for pencil beam scanning proton therapy
    Pfeiler, Tina
    Baeumer, Christian
    Engwall, Erik
    Geismar, Dirk
    Spaan, Bernhard
    Timmermann, Beate
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 121 - 133
  • [47] Selecting Optimal Proton Pencil Beam Scanning Plan Parameters to Reduce Dose Discrepancy between Discrete Spot Plan and Continuous Scanning: A Proof-of-Concept Study
    Liang, Xiaoying
    Beltran, Chris J.
    Liu, Chunbo
    Park, Chunjoo
    Lu, Bo
    Yaddanapudi, Sridhar
    Tan, Jun
    Furutani, Keith M.
    CANCERS, 2023, 15 (16)
  • [48] Experimental Validation of the Monte Carlo Model of HYPERSCAN™ Pencil Beam Scanning System for Proton Beam Imaging and Radiation Treatment
    Huo, W.
    Zwart, T.
    Finley, C.
    Jee, K.
    Sharp, G.
    Rosenthal, S.
    Xu, X.
    Lu, H.
    MEDICAL PHYSICS, 2017, 44 (06) : 2872 - 2872
  • [49] Pencil Beam Algorithm on the GEANT4 Based Simulation Framework and Verification of the Dose Distributions for Proton Therapy
    Aso, Tsukasa
    Yamashita, Tomohiro
    Akagi, Takashi
    Sasaki, Takashi
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2166 - +
  • [50] Four-dimensional Plan Optimization for the Treatment of Lung Tumors Using Pencil-beam Scanning Proton Radiotherapy
    Cummings, David
    Tang, Shikui
    Ichter, William
    Wang, Peng
    Sturgeon, Jared D.
    Lee, Andrew K.
    Chang, Chang
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2018, 10 (08)