Polyethylene spinout in the Attune® Cruciate-Retaining Rotating-Platform (CR RP) total knee arthroplasty performed with a cruciate-sacrificing and measured-resection technique

被引:3
|
作者
Keogh, Cillian J. [1 ]
Mulcahy, David [2 ]
Reidy, Declan [1 ]
Beverland, David E. [3 ]
Harty, James A. [1 ]
机构
[1] Cork Univ Hosp, Dept Trauma & Orthopaed Surg, South Infirm Victoria Univ Hosp, Cork T12 DC4A, Ireland
[2] Bon Secours Hosp Cork, Dept Orthopaed Surg, Coll Rd, Cork, Ireland
[3] Musgrave Pk Hosp, Stockmans Lane, Belfast BT9 7JB, Antrim, North Ireland
关键词
Rotating; Platform; Cruciate; Retaining; Gap; Balancing; Attune (R); LCS (R); Polyethylene; Spinout; OUTCOMES; TKA;
D O I
10.1186/s43019-020-00057-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Polyethylene (PE) spinout is a known but uncommon complication when using a mobile-bearing (MB) total knee arthroplasty (TKA) design. Sacrificing the posterior cruciate ligament (PCL) is within the manufacturer's recommendations for the Attune (R) Cruciate-Retaining Rotating-Platform (CR RP) knee design. Aim: To discuss the potential aetiology and prevention of spinout in the Attune (R) CR RP knee. Methods: We used a retrospective radiological review from two centres reporting a higher rate of spinout in the Attune (R) CR RP knee using a cruciate-sacrificing and measured-resection technique when compared to a gap-balancing technique. Three hundred and thirty-two patients were evaluated over a 3-year period. Results: There were 8 out of 279 (2.86%) cases of spinout in our first cohort of patients using a measured-resection technique. There were 0 out of 53 cases of spinout in our second cohort of patients where a gap-balancing technique was used. One spinout was reduced closed, the other seven were initially revised to a thicker RP insert of the same design. Of these seven, three underwent a further revision TKA and one patient required a knee fusion/arthrodesis. Conclusions: This study reports a higher incidence of PE spinout in the Attune (R) CR RP TKA when a measured-resection technique in combination with PCL resection is performed. We recommend a gap-balancing technique with conservative soft-tissue release if the surgeon is planning to sacrifice the PCL in the Attune (R) CR RP.
引用
收藏
页数:6
相关论文
共 41 条
  • [31] Does a Modified Gap-balancing Technique Result in Medial-pivot Knee Kinematics in Cruciate-retaining Total Knee Arthroplasty?: A Pilot Study
    Fitz, Wolfgang
    Sodha, Sonal
    Reichmann, William
    Minas, Tom
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) : 91 - 98
  • [32] A Current Prosthesis With a 1-mm Thickness Increment for Polyethylene Insert Could Result in Fewer Adjustments of Posterior Tibial Slope in Cruciate-Retaining Total Knee Arthroplasty
    Song, Sang Jun
    Lee, Hyun Woo
    Park, Cheol Hee
    JOURNAL OF ARTHROPLASTY, 2020, 35 (11): : 3172 - 3179
  • [33] All-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register
    Gudnason, Asgeir
    Hailer, Nils P.
    W-Dahl, Annette
    Sundberg, Martin
    Robertsson, Otto
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (12): : 994 - 999
  • [34] Kinematics of posterior cruciate ligament-retaining and -sacrificing mobile bearing total knee arthroplasties - An in vitro comparison of the New Jersey LCS meniscal bearing and rotating platform prostheses
    Lewandowski, PJ
    Askew, MJ
    Lin, DF
    Hurst, FW
    Melby, A
    JOURNAL OF ARTHROPLASTY, 1997, 12 (07): : 777 - 784
  • [35] Linear and Volumetric Polyethylene Wear Patterns after Primary Cruciate-Retaining Total Knee Arthroplasty Failure: An Analysis Using Optical Scanning and Computer-Aided Design Models
    Valic, Matej
    Milosev, Ingrid
    Levasic, Vesna
    Blas, Mateja
    Podovsovnik, Eva
    Koren, Jaka
    Trebse, Rihard
    MATERIALS, 2024, 17 (20)
  • [36] Comparison of Kinematics in Cruciate Retaining and Posterior Stabilized for Fixed and Rotating Platform Mobile-Bearing Total Knee Arthroplasty with respect to Different Posterior Tibial Slope
    Kang, Kyoung-Tak
    Koh, Yong-Gon
    Son, Juhyun
    Kwon, Oh-Ryong
    Lee, Jun-Sang
    Kwon, Sae Kwang
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [37] Thicker polyethylene inserts (≥ 13 mm) increase the risk for early failure after primary cruciate-retaining total knee arthroplasty (TKA): a single-centre study of 7643 TKAs
    Anni Rajamäki
    Mika Niemeläinen
    Mika Junnila
    Lari Lehtovirta
    Mari Karsikas
    Ville Ponkilainen
    Antti Eskelinen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 1018 - 1025
  • [38] Thicker polyethylene inserts (≥ 13 mm) increase the risk for early failure after primary cruciate-retaining total knee arthroplasty (TKA): a single-centre study of 7643 TKAs
    Rajamaki, Anni
    Niemelainen, Mika
    Junnila, Mika
    Lehtovirta, Lari
    Karsikas, Mari
    Ponkilainen, Ville
    Eskelinen, Antti
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (03) : 1018 - 1025
  • [39] Clinical and radiological results of cruciate-retaining total knee arthroplasty with the NexGen®-CR system: comparison of patellar resurfacing versus retention with more than 14 years of follow-upz
    Chun, Keun Churl
    Lee, Sung Hyun
    Baik, Jong Seok
    Kook, Seng Hwan
    Han, Joung Kyue
    Chun, Churl Hong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [40] Attune® Knee System Vs PFC® Sigma® Knee Systems: do newer cruciate retaining total knee arthroplasty (CR-TKA) implants provide better functional results and less patellar overload in CR-TKA with unresurfaced patellae?
    Schiapparelli, Filippo-Franco
    Amsler, Felix
    Hirschmann, Michael T.
    SWISS MEDICAL WEEKLY, 2018, 148 : 55S - 55S