Off-line tracking of series parameters in distribution systems using AMI data

被引:5
|
作者
Williams, Tess L. [1 ]
Sun, Yannan [1 ]
Schneider, Kevin [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
Distribution system analysis; Parameter estimation; State estimation; Change detection; STATE ESTIMATION; IDENTIFICATION; ERRORS;
D O I
10.1016/j.epsr.2015.12.036
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the past, electric distribution systems have lacked measurement points, and equipment is often operated to its failure point, resulting in customer outages. The widespread deployment of sensors improves distribution level observability. This paper presents an off-line parameter tracking procedure that leverages the increased deployment of distribution level measurement devices to estimate changes in impedance parameters over time. Parameter tracking enables the discovery of non-diurnal and non-seasonal changes, which can be flagged for investigation. The presented method uses an unbalanced distribution-system state-estimator and a measurement-residual based parameter-estimation procedure. Measurement residuals from multiple measurement snapshots are combined to increase effective local redundancy and improve robustness to measurement noise. The input data used in the experiments Consists of data from devices on the primary distribution system and from customer meters, via an AMI system. Results of simulations on the IEEE 13-Node Test Feeder with 307 measurements and 246 parameters are presented to illustrate the proposed approach applied to changes in series impedance parameters. The proposed approach can detect a 5% change in series resistance elements with 2% measurement error using less than 1 day of measurement snapshots for a single estimate. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 50 条
  • [21] OFF-LINE SYSTEM FOR DATA ACQUISITION AND ANALYSIS
    MASTER, RC
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1971, 48 (05) : 191 - &
  • [22] Off-line validation of power network branch parameters
    Do Coutto Filho, M. B.
    Stacchini de Souza, J. C.
    Meza, E. B. M.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2008, 2 (06) : 892 - 905
  • [23] Modeling Privacy for Off-Line RFID Systems
    Garcia, Flavio D.
    van Rossum, Peter
    SMART CARD RESEARCH AND ADVANCED APPLICATION, PROCEEDINGS, 2010, 6035 : 194 - 208
  • [24] Selection of model parameters for off-line parameter estimation
    Li, RJ
    Henson, MA
    Kurtz, MJ
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2004, 12 (03) : 402 - 412
  • [25] Combining on-line and off-line systems for handwriting recognition
    Liwicki, Marcus
    Bunke, Horst
    ICDAR 2007: NINTH INTERNATIONAL CONFERENCE ON DOCUMENT ANALYSIS AND RECOGNITION, VOLS I AND II, PROCEEDINGS, 2007, : 372 - 376
  • [26] Off-line design of PAT systems for on-line applications
    Singh, Ravendra
    Gernaey, Krist V.
    Gani, Rafiqul
    18TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2008, 25 : 423 - 428
  • [27] Addressing the Challenge of Data Interoperability for Off-Line Analysis of Distribution Networks in the Smart Grid
    McMorran, A. W.
    Stewart, E. M.
    Shand, C. M.
    Rudd, S. E.
    Taylor, G. A.
    2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
  • [28] On-line Load Estimation for Distribution Automation Using AMI Data
    Singh, Urvir
    Zamani, Vahraz
    Baran, Mesut
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [29] Off-line signature verification by the tracking of feature and stroke positions
    Fang, B
    Leung, CH
    Tang, YY
    Tse, KW
    Kwok, PCK
    Wong, YK
    PATTERN RECOGNITION, 2003, 36 (01) : 91 - 101
  • [30] Tracking of feature and stroke positions for off-line signature verification
    Fang, B
    2002 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL III, PROCEEDINGS, 2002, : 965 - 968