Monte Carlo simulation code for confocal 3D micro-beam X-ray fluorescence analysis of stratifiedmaterials

被引:25
|
作者
Czyzycki, Mateusz [1 ]
Wegrzynek, Dariusz [1 ]
Wrobel, Pawel [1 ]
Lankosz, Andmarek [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, PL-30059 Krakow, Poland
关键词
TRACE-ELEMENT ANALYSIS; COMET; 81P/WILD-2; PAINT LAYERS; MU-XRF; MICROFLUORESCENCE; SPECTROSCOPY; PARTICLES; OPTICS;
D O I
10.1002/xrs.1300
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Stratified materials are of great importance for many branches of modern industry, e. g. electronics or optics and for biomedical applications. Examination of chemical composition of individual layers and determination of their thickness helps to get information on their properties and function. A confocal 3D micro X-ray fluorescence (3D mu XRF) spectroscopy is an analytical method giving the possibility to investigate 3D distribution of chemical elements in a sample with spatial resolution in the micrometer regime in a non-destructive way. Thin foils of Ti, Cu and Au, a bulk sample of Cu and a three-layered sandwich sample, made of two thin Fe/Ni alloy foils, separated by polypropylene, were used as test samples. A Monte Carlo (MC) simulation code for the determination of elemental concentrations and thickness of individual layers in stratified materials with the use of confocal 3D mu XRF spectroscopy was developed. The X-ray intensity profiles versus the depth below surface, obtained from 3D mu XRF experiments, MC simulation and an analytical approach were compared. Correlation coefficients between experimental versus simulated, and experimental versus analytical model X-ray profiles were calculated. The correlation coefficients were comparable for both methods and exceeded 99%. The experimental X-ray intensity profiles were deconvoluted with iterative MC simulation and by using analytical expression. The MC method produced slightly more accurate elemental concentrations and thickness of successive layers as compared to the results of the analytical approach. This MC code is a robust tool for simulation of scanning confocal 3D mu XRF experiments on stratified materials and for quantitative interpretation of experimental results. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:88 / 95
页数:8
相关论文
共 50 条
  • [41] Preliminary investigation of trace element in Pterygium using Synchrotron radiation micro-beam X-ray fluorescence analysis (μ-XRF)
    Xie, Q.
    Peng, L.
    Cai, F.
    Li, Ai G.
    Yang, K.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [42] A compact 3D micro X-ray fluorescence spectrometer with X-ray tube excitation for archaeometric applications
    Mantouvalou, Ioanna
    Lange, Kathrin
    Wolff, Timo
    Groetzsch, Daniel
    Luehl, Lars
    Haschke, Michael
    Hahn, Oliver
    Kanngiesser, Birgit
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (04) : 554 - 561
  • [43] Direct deconvolution approach for depth profiling of element concentrations in multi-layered materials by confocal micro-beam X-ray fluorescence spectrometry
    Wrobel, Pawel
    Czyzycki, Mateusz
    TALANTA, 2013, 113 : 62 - 67
  • [44] Monte Carlo simulation analysis of X-ray density logging shields
    Liu, Rui
    Yu, Huawei
    Zhu, Qian
    Yue, Aizhong
    Wang, Hu
    Liu, Chaozhuo
    Zhang, Qianwen
    Yang, Shu
    Zhu, Linke
    Zhang, Xiaolei
    He Jishu/Nuclear Techniques, 2024, 47 (08):
  • [45] Monte Carlo simulation applied in Total Reflection X-Ray Fluorescence: preliminary results
    Meira, Luiza L. C.
    Inocente, Guilherme F.
    Vieira, Leticia D.
    Mesa, Joel
    XXXV BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2013, 1529 : 66 - 69
  • [46] Micro-beam X-ray absorption and fluorescence spectroscopies at GSECARS: APS beamline 13ID
    Newville, Matthew
    Sutton, Steve
    Rivers, Mark
    Eng, Peter
    Journal of Synchrotron Radiation, 1999, 6 (03): : 353 - 355
  • [47] Use of Monte Carlo simulations for cultural heritage X-ray fluorescence analysis
    Brunetti, Antonio
    Golosio, Bruno
    Schoonjans, Tom
    Oliva, Piernicola
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 108 : 15 - 20
  • [48] Monte Carlo methods for the in vivo analysis of cisplatin using X-ray fluorescence
    Hugtenburg, RP
    Turner, JR
    Mannering, DM
    Robinson, BA
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 673 - 676
  • [49] X-ray scattering in X-ray fluorescence spectra with X-ray monochromatic, polarised excitation - Modelling, experiment, and Monte-Carlo simulation
    Hodoroaba, V. -D.
    Radtke, M.
    Reinholz, U.
    Riesemeier, H.
    Vincze, L.
    Reuter, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (13): : 1493 - 1498
  • [50] Monte Carlo simulation of x-ray spectra in mammography
    Ng, KP
    Kwok, CS
    Tang, FH
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05): : 1309 - 1318